Skip to content

Boltic vs LUXCOOL: heat pump ratings compared

Against heat pumps of the same size and type, a typical Boltic model beats 34% and a typical LUXCOOL model 21%. Boltic rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Boltic

34%

of similar heat pumps beaten by its typical model

Well below average

5 models listed

LUXCOOL

21%

of similar heat pumps beaten by its typical model

Well below average

5 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FBoltic: Beats 59%LUXCOOL: Beats 57%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FBoltic: Beats 21%LUXCOOL: Beats 3%
  • Winter-long heating efficiencyHSPF2Boltic: Beats 29%LUXCOOL: Beats 4%
  • Summer-long cooling efficiencySEER2Boltic: Beats 37%LUXCOOL: Beats 14%
  • Hot-day cooling efficiencyEER2Boltic: Beats 27%LUXCOOL: Beats 25%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Boltic
    40%
    LUXCOOL
    40%
  • Xcel CC

    Boltic
    40%
    LUXCOOL
    0%
  • CEE Advanced

    Boltic
    0%
    LUXCOOL
    0%
  • ENERGY STAR CC

    Boltic
    0%
    LUXCOOL
    0%

All-around best, ductless up to 1.5 tons

Boltic

  1. 187A9KODUwith ductless indoor unit 87A9KIDUBoltic1 ton · 9,000 Btu/h · DuctlessCold-climate pick, score 36.6Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    70% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.95 (COP at 5°F)
    Good
    Winter efficiency
    9.0 (HSPF2)
    Below the middle
    Cooling efficiency
    21.5 (SEER2)
    Good
    Hot-day cooling
    12.5 (EER2)
    Good
    47.3score / 100Heating 37 · Cooling 58
  2. 287A18KODUwith ductless indoor unit 87A18KIDUBoltic1.5 tons · 18,000 Btu/h · DuctlessNot a cold-climate pick: keeps 61% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    61% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.99 (COP at 5°F)
    Good
    Winter efficiency
    9.1 (HSPF2)
    Below the middle
    Cooling efficiency
    20.2 (SEER2)
    Below the middle
    Hot-day cooling
    11.5 (EER2)
    Below the middle
    36.9score / 100Heating 35 · Cooling 39
  3. 387A12KODUwith ductless indoor unit 87A12KIDUBoltic1 ton · 12,000 Btu/h · DuctlessNot a cold-climate pick: keeps 58% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    58% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.85 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.7 (HSPF2)
    Below the middle
    Cooling efficiency
    21.3 (SEER2)
    Good
    Hot-day cooling
    10.0 (EER2)
    Below the middle
    28.5score / 100Heating 22 · Cooling 35

LUXCOOL

  1. 1LUX-18CVA-Owith ductless indoor unit LUX-18CVA-ILUXCOOL1.5 tons · 17,100 Btu/h · DuctlessNot a cold-climate pick: keeps 55% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    55% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.22 (COP at 5°F)
    Great
    Winter efficiency
    8.2 (HSPF2)
    Below the middle
    Cooling efficiency
    18.1 (SEER2)
    Below the middle
    Hot-day cooling
    11.6 (EER2)
    Below the middle
    29.8score / 100Heating 32 · Cooling 27
  2. 2LUX-12CVA2-Owith ductless indoor unit LUX-12CVA2-ILUXCOOL1 ton · 12,000 Btu/h · DuctlessNot a cold-climate pick: keeps 48% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    48% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.67 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.2 (HSPF2)
    Below the middle
    Cooling efficiency
    18.1 (SEER2)
    Below the middle
    Hot-day cooling
    10.8 (EER2)
    Below the middle
    11.8score / 100Heating 2 · Cooling 22
  3. 3LUX-12CVA-Owith ductless indoor unit LUX-12CVA-ILUXCOOL1 ton · 12,100 Btu/h · DuctlessNot a cold-climate pick: keeps 51% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    52% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.76 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.2 (HSPF2)
    Below the middle
    Cooling efficiency
    18.1 (SEER2)
    Below the middle
    Hot-day cooling
    8.8 (EER2)
    Below the middle
    6.7score / 100Heating 5 · Cooling 8

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter