Both views use the same certified data. This device remembers your choice.
Breeze33 vs Dial: heat pump ratings compared
Against heat pumps of the same size and type, a typical Breeze33 model beats 63% and a typical Dial model 55%. Breeze33 rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Breeze33
63%
of similar heat pumps beaten by its typical model
Well above average45 models listed
Dial
55%
of similar heat pumps beaten by its typical model
About average45 models listed
- Efficiency on a 5°F dayCOP at 5°FBreeze33: Beats 63%Dial: Beats 55%
- Heating power kept at 5°FCapacity at 5°F vs 47°FBreeze33: Beats 58%Dial: Beats 54%
- Winter-long heating efficiencyHSPF2Breeze33: Beats 67%Dial: Beats 62%
- Summer-long cooling efficiencySEER2Breeze33: Beats 58%Dial: Beats 58%
- Hot-day cooling efficiencyEER2Breeze33: Beats 68%Dial: Beats 48%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- Breeze33
- 67%
- Dial
- 73%
Xcel CC
- Breeze33
- 58%
- Dial
- 69%
CEE Advanced
- Breeze33
- 4%
- Dial
- 0%
ENERGY STAR CC
- Breeze33
- 56%
- Dial
- 0%
All-around best, ductless up to 1.5 tons
Showing Ductless, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
Breeze33
- 1BZ33-HYP06OUT2-454-G3-Pwith ductless indoor unit BZ33-HYP06WALL2-454-G3-PBreeze330.5 tons · 6,000 Btu/h · DuctlessCold-climate pick, score 97.0Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 110% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.40 (COP at 5°F)
- Top 10%
- Winter efficiency
- 14.8 (HSPF2)
- Top 10%
- Cooling efficiency
- 25.5 (SEER2)
- Top 10%
- Hot-day cooling
- 18.0 (EER2)
- Top 10%
- 2BZ33-HYP09OUT2-454-G3-Pwith ductless indoor unit BZ33-ICM09-454-G3-PBreeze331 ton · 9,000 Btu/h · DuctlessCold-climate pick, score 74.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 126% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.84 (COP at 5°F)
- Below the middle
- Winter efficiency
- 10.9 (HSPF2)
- Great
- Cooling efficiency
- 27.2 (SEER2)
- Top 10%
- Hot-day cooling
- 15.1 (EER2)
- Top 10%
- 3BZ33-HYP183Z2-454-G3-PBreeze331.5 tons · 19,000 Btu/h · DuctlessCold-climate pick, score 74.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 95% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.4 (HSPF2)
- Great
- Cooling efficiency
- 25.0 (SEER2)
- Great
- Hot-day cooling
- 15.0 (EER2)
- Top 10%
Dial
- 1DAP091H2A1with ductless indoor unit DAP09V2A1Dial1 ton · 9,000 Btu/h · DuctlessCold-climate pick, score 74.2Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 126% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.84 (COP at 5°F)
- Below the middle
- Winter efficiency
- 10.9 (HSPF2)
- Great
- Cooling efficiency
- 27.2 (SEER2)
- Top 10%
- Hot-day cooling
- 15.1 (EER2)
- Top 10%
- 2DAP181H2A1with ductless indoor unit DAP18W2A1Dial1.5 tons · 18,000 Btu/h · DuctlessCold-climate pick, score 79.5Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.8 (HSPF2)
- Great
- Cooling efficiency
- 21.7 (SEER2)
- Good
- Hot-day cooling
- 13.0 (EER2)
- Good
- 3DAP121H2A1with ductless indoor unit DAP12N2A1Dial1 ton · 12,000 Btu/h · DuctlessCold-climate pick, score 79.8Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 92% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.0 (HSPF2)
- Good
- Cooling efficiency
- 23.0 (SEER2)
- Good
- Hot-day cooling
- 13.0 (EER2)
- Good
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view