Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Carrier vs Daikin: heat pump ratings compared
Against heat pumps of the same size and type, a typical Carrier model beats 48% and a typical Daikin model 50%. Daikin rates slightly higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Carrier
48%
of similar heat pumps beaten by its typical model
About average816 models listed
Daikin
50%
of similar heat pumps beaten by its typical model
About average394 models listed
- Efficiency on a 5°F dayCOP at 5°FCarrier: Beats 56%Daikin: Beats 46%
- Heating power kept at 5°FCapacity at 5°F vs 47°FCarrier: Beats 34%Daikin: Beats 48%
- Winter-long heating efficiencyHSPF2Carrier: Beats 40%Daikin: Beats 38%
- Summer-long cooling efficiencySEER2Carrier: Beats 42%Daikin: Beats 45%
- Hot-day cooling efficiencyEER2Carrier: Beats 59%Daikin: Beats 54%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- Carrier
- 40%
- Daikin
- 38%
Xcel CC
- Carrier
- 27%
- Daikin
- 30%
CEE Advanced
- Carrier
- 1%
- Daikin
- 2%
ENERGY STAR CC
- Carrier
- 27%
- Daikin
- 17%
All-around best, ducted up to 1.5 tons
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
Carrier
- 137MAHAQ06AA3with ducted air handler 45MBDAQ06XA3CarrierAlso sold as Arcoaire D5CSHAH06AAK0.5 tons · 6,500 Btu/h · DuctedCold-climate pick, score 93.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 98% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.41 (COP at 5°F)
- Top 10%
- Winter efficiency
- 13.8 (HSPF2)
- Top 10%
- Cooling efficiency
- 21.5 (SEER2)
- Top 10%
- Hot-day cooling
- 14.5 (EER2)
- Top 10%
- 237MAHAQ09AA3with ducted air handler 45MBDAQ12XA3CarrierAlso sold as Arcoaire D5CSHAH09AAK1 ton · 9,000 Btu/h · DuctedCold-climate pick, score 80.0Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 112% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.89 (COP at 5°F)
- Below the middle
- Winter efficiency
- 12.5 (HSPF2)
- Top 10%
- Cooling efficiency
- 21.5 (SEER2)
- Top 10%
- Hot-day cooling
- 13.5 (EER2)
- Top 10%
- 337MARAQ09AA3with ducted air handler 45MBDAQ12XH3CarrierAlso sold as Arcoaire D5CSRAH09AAK1 ton · 9,000 Btu/h · DuctedCold-climate pick, score 81.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 83% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.32 (COP at 5°F)
- Great
- Winter efficiency
- 11.5 (HSPF2)
- Top 10%
- Cooling efficiency
- 19.8 (SEER2)
- Great
- Hot-day cooling
- 13.0 (EER2)
- Great
Daikin
- 1RZA18AAVJU*with ducted air handler FBA18A*VJUDaikin1.5 tons · 18,000 Btu/h · DuctedCold-climate pick, score 62.5Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 101% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.94 (COP at 5°F)
- Good
- Winter efficiency
- 8.5 (HSPF2)
- Below the middle
- Cooling efficiency
- 16.3 (SEER2)
- Good
- Hot-day cooling
- 13.5 (EER2)
- Top 10%
- 2DH6VSA1810A*with indoor coil CA*EA3022*3A and furnace D*96TC0804CNADaikinAlso sold as Amana AZV6SA1810A, Goodman GZV6SA1810A1.5 tons · 17,000 Btu/h · DuctedCold-climate pick, score 53.4Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 77% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 8.8 (HSPF2)
- Below the middle
- Cooling efficiency
- 19.0 (SEER2)
- Good
- Hot-day cooling
- 12.0 (EER2)
- Good
- 3RXP15AVJU*with ducted air handler FDMA15AVJUDaikin1 ton · 14,400 Btu/h · DuctedCold-climate pick, score 60.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.2 (HSPF2)
- Good
- Cooling efficiency
- 18.0 (SEER2)
- Good
- Hot-day cooling
- 11.8 (EER2)
- Good
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.