Skip to content

Carrier vs Hisense: heat pump ratings compared

Against heat pumps of the same size and type, a typical Carrier model beats 49% and a typical Hisense model 54%. Hisense rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Carrier

49%

of similar heat pumps beaten by its typical model

About average

846 models listed

Hisense

54%

of similar heat pumps beaten by its typical model

About average

168 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FCarrier: Beats 57%Hisense: Beats 59%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FCarrier: Beats 36%Hisense: Beats 61%
  • Winter-long heating efficiencyHSPF2Carrier: Beats 41%Hisense: Beats 51%
  • Summer-long cooling efficiencySEER2Carrier: Beats 43%Hisense: Beats 57%
  • Hot-day cooling efficiencyEER2Carrier: Beats 60%Hisense: Beats 47%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Carrier
    42%
    Hisense
    80%
  • Xcel CC

    Carrier
    29%
    Hisense
    67%
  • CEE Advanced

    Carrier
    1%
    Hisense
    7%
  • ENERGY STAR CC

    Carrier
    27%
    Hisense
    54%

All-around best, ductless 2 tons

Carrier

  1. 137MARAQ24AA3with ductless indoor unit 45MAHAQ24XA3CarrierAlso sold as Arcoaire D5CSRAH24AAK2 tons · 24,000 Btu/h · DuctlessCold-climate pick, score 85.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    78% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.54 (COP at 5°F)
    Top 10%
    Winter efficiency
    11.7 (HSPF2)
    Top 10%
    Cooling efficiency
    23.1 (SEER2)
    Great
    Hot-day cooling
    14.0 (EER2)
    Top 10%
    89.4score / 100Heating 86 · Cooling 93
  2. 2RAV-BP241AT2P-ULwith ductless indoor unit RAV-HB241UTP-ULCarrier (sold as Toshiba Carrier)2 tons · 24,000 Btu/h · DuctlessCold-climate pick, score 80.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    81% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    11.1 (HSPF2)
    Top 10%
    Cooling efficiency
    24.2 (SEER2)
    Top 10%
    Hot-day cooling
    13.8 (EER2)
    Top 10%
    85.4score / 100Heating 77 · Cooling 94
  3. 337MAHAQ24AA3with ductless indoor unit 45MAHAQ24XA3CarrierAlso sold as Arcoaire D5CSHAH24AAK2 tons · 24,000 Btu/h · DuctlessCold-climate pick, score 90.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    83% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.34 (COP at 5°F)
    Top 10%
    Winter efficiency
    13.5 (HSPF2)
    Top 10%
    Cooling efficiency
    21.2 (SEER2)
    Good
    Hot-day cooling
    13.0 (EER2)
    Great
    80.5score / 100Heating 90 · Cooling 71

Hisense

  1. 1AST-24UW3TKN00with ductless indoor unit AST-24UW3TKN**00Hisense2 tons · 24,000 Btu/h · DuctlessCold-climate pick, score 56.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    83% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Below the middle
    Cooling efficiency
    22.5 (SEER2)
    Good
    Hot-day cooling
    12.3 (EER2)
    Good
    63.6score / 100Heating 56 · Cooling 71
  2. 2AST-24UW3TKW00with ductless indoor unit AST-24UW3TKW**00HisenseAlso listed as AO-24U3T25U, AO-24U3T26U22 tons · 24,000 Btu/h · DuctlessCold-climate pick, score 55.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    80% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Below the middle
    Cooling efficiency
    22.5 (SEER2)
    Good
    Hot-day cooling
    12.3 (EER2)
    Good
    63.1score / 100Heating 55 · Cooling 71
  3. 3AUW-24U3TK1with ductless indoor unit ACT-24UR3TJA1HisenseAlso listed as AOU-24U3T25U2 tons · 24,000 Btu/h · DuctlessCold-climate pick, score 76.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.5 (HSPF2)
    Great
    Cooling efficiency
    20.0 (SEER2)
    Below the middle
    Hot-day cooling
    12.0 (EER2)
    Good
    62.6score / 100Heating 77 · Cooling 48

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter