Skip to content

Carrier vs Hisense: heat pump ratings compared

Against heat pumps of the same size and type, a typical Carrier model beats 49% and a typical Hisense model 54%. Hisense rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Carrier

49%

of similar heat pumps beaten by its typical model

About average

846 models listed

Hisense

54%

of similar heat pumps beaten by its typical model

About average

168 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FCarrier: Beats 57%Hisense: Beats 59%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FCarrier: Beats 36%Hisense: Beats 61%
  • Winter-long heating efficiencyHSPF2Carrier: Beats 41%Hisense: Beats 51%
  • Summer-long cooling efficiencySEER2Carrier: Beats 43%Hisense: Beats 57%
  • Hot-day cooling efficiencyEER2Carrier: Beats 60%Hisense: Beats 47%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Carrier
    42%
    Hisense
    80%
  • Xcel CC

    Carrier
    29%
    Hisense
    67%
  • CEE Advanced

    Carrier
    1%
    Hisense
    7%
  • ENERGY STAR CC

    Carrier
    27%
    Hisense
    54%

All-around best, ductless up to 1.5 tons

Carrier

  1. 137MAHAQ06AA3with ductless indoor unit 45MAHAQ06XA3CarrierAlso sold as Arcoaire D5CSHAH06AAK0.5 tons · 6,000 Btu/h · DuctlessCold-climate pick, score 97.0Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    110% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.40 (COP at 5°F)
    Top 10%
    Winter efficiency
    14.8 (HSPF2)
    Top 10%
    Cooling efficiency
    25.7 (SEER2)
    Top 10%
    Hot-day cooling
    18.0 (EER2)
    Top 10%
    96.9score / 100Heating 97 · Cooling 97
  2. 2W5HD606K1X1Awith ductless indoor unit W5BSR06K1AAACarrier (sold as Grandaire)0.5 tons · 6,000 Btu/h · DuctlessCold-climate pick, score 97.0Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    110% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.40 (COP at 5°F)
    Top 10%
    Winter efficiency
    14.8 (HSPF2)
    Top 10%
    Cooling efficiency
    25.5 (SEER2)
    Top 10%
    Hot-day cooling
    18.0 (EER2)
    Top 10%
    96.6score / 100Heating 97 · Cooling 96
  3. 337MPRAQ06AA3with ductless indoor unit 45MPHAQ06XA3Carrier0.5 tons · 6,000 Btu/h · DuctlessCold-climate pick, score 88.0Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    150% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    15.6 (HSPF2)
    Top 10%
    Cooling efficiency
    35.1 (SEER2)
    Top 10%
    Hot-day cooling
    17.5 (EER2)
    Top 10%
    93.7score / 100Heating 88 · Cooling 100

Hisense

  1. 1AS-09UW3TBW00with ductless indoor unit AS-09UW3TBW**00HisenseAlso listed as AO-09U3T25P, AO-09U3T26P21 ton · 9,000 Btu/h · DuctlessCold-climate pick, score 90.7Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.25 (COP at 5°F)
    Top 10%
    Winter efficiency
    11.8 (HSPF2)
    Top 10%
    Cooling efficiency
    32.0 (SEER2)
    Top 10%
    Hot-day cooling
    18.4 (EER2)
    Top 10%
    95.0score / 100Heating 91 · Cooling 99
  2. 2AO-12U3T25Pwith ductless indoor unit AS-12U3THE25PHisenseAlso listed as AO-12U3T26P21 ton · 12,000 Btu/h · DuctlessCold-climate pick, score 91.8Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    102% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.25 (COP at 5°F)
    Top 10%
    Winter efficiency
    11.8 (HSPF2)
    Top 10%
    Cooling efficiency
    30.0 (SEER2)
    Top 10%
    Hot-day cooling
    15.4 (EER2)
    Top 10%
    94.6score / 100Heating 92 · Cooling 97
  3. 3AS-12UW3TBW00with ductless indoor unit AS-12UW3TBW**00Hisense1 ton · 12,000 Btu/h · DuctlessCold-climate pick, score 90.7Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.25 (COP at 5°F)
    Top 10%
    Winter efficiency
    11.8 (HSPF2)
    Top 10%
    Cooling efficiency
    30.0 (SEER2)
    Top 10%
    Hot-day cooling
    15.4 (EER2)
    Top 10%
    94.1score / 100Heating 91 · Cooling 97

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter