Both views use the same certified data. This device remembers your choice.
Carrier vs Nortek Global HVAC: heat pump ratings compared
Against heat pumps of the same size and type, a typical Carrier model beats 49% and a typical Nortek Global HVAC model 32%. Carrier rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Carrier
49%
of similar heat pumps beaten by its typical model
About average846 models listed
Nortek Global HVAC
32%
of similar heat pumps beaten by its typical model
Well below average109 models listed
- Efficiency on a 5°F dayCOP at 5°FCarrier: Beats 57%Nortek Global HVAC: Beats 24%
- Heating power kept at 5°FCapacity at 5°F vs 47°FCarrier: Beats 36%Nortek Global HVAC: Beats 28%
- Winter-long heating efficiencyHSPF2Carrier: Beats 41%Nortek Global HVAC: Beats 28%
- Summer-long cooling efficiencySEER2Carrier: Beats 43%Nortek Global HVAC: Beats 32%
- Hot-day cooling efficiencyEER2Carrier: Beats 60%Nortek Global HVAC: Beats 42%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- Carrier
- 42%
- Nortek Global HVAC
- 28%
Xcel CC
- Carrier
- 29%
- Nortek Global HVAC
- 20%
CEE Advanced
- Carrier
- 1%
- Nortek Global HVAC
- 2%
ENERGY STAR CC
- Carrier
- 27%
- Nortek Global HVAC
- 11%
All-around best, ducted 2 tons
Showing Ducted, 2 tons (21,000 to 26,999 Btu/h cooling). What size is my system?
Carrier
- 127VNA324A*030*with ducted air handler FE5BN(B,X)C36L*+UICarrierAlso sold as Bryant Heating and Cooling Systems 293VAN024**AA, HEIL B5H3V24*K*AAA2 tons · 22,800 Btu/h · DuctedCold-climate pick, score 70.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 77% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.06 (COP at 5°F)
- Good
- Winter efficiency
- 10.5 (HSPF2)
- Top 10%
- Cooling efficiency
- 21.5 (SEER2)
- Top 10%
- Hot-day cooling
- 13.0 (EER2)
- Top 10%
- 2RAV-BP241AT2P-ULwith ducted air handler RAV-HB241BTP-ULCarrier (sold as Toshiba Carrier)2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 77.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 81% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Great
- Winter efficiency
- 10.5 (HSPF2)
- Top 10%
- Cooling efficiency
- 19.4 (SEER2)
- Great
- Hot-day cooling
- 12.5 (EER2)
- Great
- 337MAHAQ24AA3with ducted air handler 45MBDAQ24XH3CarrierAlso sold as Arcoaire D5CSHAH24AAK2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 85.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 92% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.18 (COP at 5°F)
- Good
- Winter efficiency
- 11.7 (HSPF2)
- Top 10%
- Cooling efficiency
- 19.2 (SEER2)
- Great
- Hot-day cooling
- 12.0 (EER2)
- Good
Nortek Global HVAC
- 1DXH24FMK3IHNortek Global HVAC (sold as Gibson)2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 48.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 90% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.86 (COP at 5°F)
- Below the middle
- Winter efficiency
- 8.1 (HSPF2)
- Below the middle
- Cooling efficiency
- 18.0 (SEER2)
- Good
- Hot-day cooling
- 12.0 (EER2)
- Good
- 2SH4BF5M2SX24Kwith ducted air handler B65VMMX24K-BNortek Global HVAC (sold as Nortek Global Hvac Llc)Also sold as Frigidaire FSH4BF5M2SX24K, Maytag PSH4BF5M2SX24K2 tons · 24,000 Btu/h · DuctedNot a cold-climate pick: keeps 48% of its heat at 5°FMeets CEE 2025
- Heat kept at 5°F
- 48% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.75 (COP at 5°F)
- Below the middle
- Winter efficiency
- 8.0 (HSPF2)
- Below the middle
- Cooling efficiency
- 16.0 (SEER2)
- Below the middle
- Hot-day cooling
- 11.7 (EER2)
- Below the middle
- 3SH4ME5M1SP24Kwith indoor coil C75B(A,H)MX24C*B and furnace MG3P-054U1AABNortek Global HVAC (sold as Nordyne)Also sold as Intertherm HSH4ME5M1SP24K2 tons · 23,400 Btu/h · DuctedNot a cold-climate pick: keeps 50% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 51% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.75 (COP at 5°F)
- Below the middle
- Winter efficiency
- 7.5 (HSPF2)
- Below the middle
- Cooling efficiency
- 14.3 (SEER2)
- Below the middle
- Hot-day cooling
- 11.0 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view