Both views use the same certified data. This device remembers your choice.
Classic America vs SINCLAIR AIR CONDITIONING: heat pump ratings compared
Against heat pumps of the same size and type, a typical Classic America model beats 33% and a typical SINCLAIR AIR CONDITIONING model 54%. SINCLAIR AIR CONDITIONING rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Classic America
33%
of similar heat pumps beaten by its typical model
Well below average9 models listed
SINCLAIR AIR CONDITIONING
54%
of similar heat pumps beaten by its typical model
About average9 models listed
- Efficiency on a 5°F dayCOP at 5°FClassic America: Beats 33%SINCLAIR AIR CONDITIONING: Beats 79%
- Heating power kept at 5°FCapacity at 5°F vs 47°FClassic America: Beats 24%SINCLAIR AIR CONDITIONING: Beats 25%
- Winter-long heating efficiencyHSPF2Classic America: Beats 44%SINCLAIR AIR CONDITIONING: Beats 45%
- Summer-long cooling efficiencySEER2Classic America: Beats 38%SINCLAIR AIR CONDITIONING: Beats 42%
- Hot-day cooling efficiencyEER2Classic America: Beats 28%SINCLAIR AIR CONDITIONING: Beats 76%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- Classic America
- 44%
- SINCLAIR AIR CONDITIONING
- 33%
Xcel CC
- Classic America
- 44%
- SINCLAIR AIR CONDITIONING
- 11%
CEE Advanced
- Classic America
- 0%
- SINCLAIR AIR CONDITIONING
- 0%
ENERGY STAR CC
- Classic America
- 44%
- SINCLAIR AIR CONDITIONING
- 0%
All-around best, ducted 3.5 to 4.5 tons
Showing Ducted, 3.5 to 4.5 tons (39,000 to 56,999 Btu/h cooling). What size is my system?
Classic America
No ducted, 3.5 to 4.5 tons model from Classic America.
SINCLAIR AIR CONDITIONING
- 1BH714S42P-**Awith indoor coil BC748[C,U]CT-**+TDR and furnace B80UR901E5CSINCLAIR AIR CONDITIONING3.5 tons · 41,500 Btu/h · DuctedNot a cold-climate pick: keeps 51% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 52% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.12 (COP at 5°F)
- Great
- Winter efficiency
- 7.8 (HSPF2)
- Below the middle
- Cooling efficiency
- 15.5 (SEER2)
- Below the middle
- Hot-day cooling
- 13.0 (EER2)
- Top 10%
- 2BH714S48P-**Awith indoor coil BC760[C,U]CT-**+TDR and furnace B80UR1102E5CSINCLAIR AIR CONDITIONING4 tons · 48,000 Btu/h · DuctedNot a cold-climate pick: keeps 52% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 51% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.14 (COP at 5°F)
- Great
- Winter efficiency
- 8.1 (HSPF2)
- Good
- Cooling efficiency
- 15.2 (SEER2)
- Below the middle
- Hot-day cooling
- 12.8 (EER2)
- Top 10%
- 3BH719M60P-**Awith indoor coil BC750/60DCT-**+TDR and furnace B80DR1101E5CSINCLAIR AIR CONDITIONING4 tons · 47,500 Btu/h · DuctedNot a cold-climate pick: keeps 56% of its heat at 5°FMeets CEE 2025, CEE 2026
- Heat kept at 5°F
- 60% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.96 (COP at 5°F)
- Below the middle
- Winter efficiency
- 8.0 (HSPF2)
- Below the middle
- Cooling efficiency
- 18.0 (SEER2)
- Great
- Hot-day cooling
- 11.7 (EER2)
- Great
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view