CLASSIC vs Kerr: heat pump ratings compared
Against heat pumps of the same size and type, a typical CLASSIC model beats 42% and a typical Kerr model 67%. Kerr rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
CLASSIC
42%
of similar heat pumps beaten by its typical model
Below average40 models listed
Kerr
67%
of similar heat pumps beaten by its typical model
Well above average38 models listed
- Efficiency on a 5°F dayCOP at 5°FCLASSIC: Beats 37%Kerr: Beats 59%
- Heating power kept at 5°FCapacity at 5°F vs 47°FCLASSIC: Beats 45%Kerr: Beats 78%
- Winter-long heating efficiencyHSPF2CLASSIC: Beats 39%Kerr: Beats 79%
- Summer-long cooling efficiencySEER2CLASSIC: Beats 46%Kerr: Beats 64%
- Hot-day cooling efficiencyEER2CLASSIC: Beats 40%Kerr: Beats 63%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- CLASSIC
- 65%
- Kerr
- 79%
Xcel CC
- CLASSIC
- 65%
- Kerr
- 90%
CEE Advanced
- CLASSIC
- 3%
- Kerr
- 3%
ENERGY STAR CC
- CLASSIC
- 20%
- Kerr
- 90%
All-around best, ducted 2 tons
Showing Ducted, 2 tons (21,000 to 26,999 Btu/h cooling). What size is my system?
CLASSIC
- 1OCV18HN024Awith ducted air handler OCA18C002ACLASSICAlso listed as OCV18HN036A2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 67.6Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 79% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.15 (COP at 5°F)
- Good
- Winter efficiency
- 9.5 (HSPF2)
- Good
- Cooling efficiency
- 19.0 (SEER2)
- Great
- Hot-day cooling
- 13.2 (EER2)
- Top 10%
- 2GMRSHC24AS3CLASSIC2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 48.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 90% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.86 (COP at 5°F)
- Below the middle
- Winter efficiency
- 8.1 (HSPF2)
- Below the middle
- Cooling efficiency
- 18.0 (SEER2)
- Good
- Hot-day cooling
- 12.0 (EER2)
- Good
- 3TMRHC27AS3CLASSIC2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 56.3Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 19.0 (SEER2)
- Great
- Hot-day cooling
- 11.0 (EER2)
- Below the middle
Kerr
- 1A-KHP24SA-1with ducted air handler B-KHP24DA-1Kerr2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 85.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 92% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.18 (COP at 5°F)
- Good
- Winter efficiency
- 11.7 (HSPF2)
- Top 10%
- Cooling efficiency
- 19.0 (SEER2)
- Great
- Hot-day cooling
- 12.0 (EER2)
- Good
- 2A-KXP24SA-1with ducted air handler B-KXP24SA-1Kerr2 tons · 23,000 Btu/h · DuctedCold-climate pick, score 66.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 90% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.87 (COP at 5°F)
- Below the middle
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 18.3 (SEER2)
- Good
- Hot-day cooling
- 11.7 (EER2)
- Below the middle
- 3A-KXP24TA-1with ducted air handler KXP18/24A1AKerr2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 54.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 84% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.5 (HSPF2)
- Good
- Cooling efficiency
- 16.0 (SEER2)
- Below the middle
- Hot-day cooling
- 10.0 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.