Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
CLASSIC vs Mitsutomo: heat pump ratings compared
Against heat pumps of the same size and type, a typical CLASSIC model beats 41% and a typical Mitsutomo model 58%. Mitsutomo rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
CLASSIC
41%
of similar heat pumps beaten by its typical model
Below average40 models listed
Mitsutomo
58%
of similar heat pumps beaten by its typical model
Above average56 models listed
- Efficiency on a 5°F dayCOP at 5°FCLASSIC: Beats 37%Mitsutomo: Beats 61%
- Heating power kept at 5°FCapacity at 5°F vs 47°FCLASSIC: Beats 43%Mitsutomo: Beats 58%
- Winter-long heating efficiencyHSPF2CLASSIC: Beats 37%Mitsutomo: Beats 69%
- Summer-long cooling efficiencySEER2CLASSIC: Beats 45%Mitsutomo: Beats 57%
- Hot-day cooling efficiencyEER2CLASSIC: Beats 40%Mitsutomo: Beats 51%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- CLASSIC
- 65%
- Mitsutomo
- 82%
Xcel CC
- CLASSIC
- 65%
- Mitsutomo
- 75%
CEE Advanced
- CLASSIC
- 3%
- Mitsutomo
- 4%
ENERGY STAR CC
- CLASSIC
- 20%
- Mitsutomo
- 77%
Top cold-climate picks, ducted up to 1.5 tons
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
CLASSIC
- 1TMRHC18AS2CLASSIC1.5 tons · 18,000 Btu/h · DuctedKeeps 70% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 9.5 (HSPF2)
- Good
- 2GMRSHC18AS2CLASSIC1.5 tons · 18,000 Btu/h · DuctedKeeps 76% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 76% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.86 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 8.1 (HSPF2)
- Below the middle
Mitsutomo
- 1HO-SZ06-LA-Qwith ducted air handler HD-UZ06-LA-QMitsutomo0.5 tons · 6,500 Btu/h · DuctedKeeps 98% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 98% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.41 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 13.8 (HSPF2)
- Top 10%
- 2UHO18-NB-LA-Qwith ducted air handler UHMX3-18-AB-LA-QMitsutomo1.5 tons · 18,000 Btu/h · DuctedKeeps 103% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 103% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.12 (COP at 5°F)
- Great
- Seasonal efficiency
- 10.1 (HSPF2)
- Great
- 3HO-SZ18-LA-Qwith ducted air handler S-HD-UZ18-LA-QMitsutomo1.5 tons · 17,500 Btu/h · DuctedKeeps 92% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 92% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Seasonal efficiency
- 11.1 (HSPF2)
- Top 10%
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view