Both views use the same certified data. This device remembers your choice.
COMFORTSTAR vs Mitsubishi Electric: heat pump ratings compared
Against heat pumps of the same size and type, a typical COMFORTSTAR model beats 50% and a typical Mitsubishi Electric model 61%. Mitsubishi Electric rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
COMFORTSTAR
50%
of similar heat pumps beaten by its typical model
About average147 models listed
Mitsubishi Electric
61%
of similar heat pumps beaten by its typical model
Well above average156 models listed
- Efficiency on a 5°F dayCOP at 5°FCOMFORTSTAR: Beats 51%Mitsubishi Electric: Beats 56%
- Heating power kept at 5°FCapacity at 5°F vs 47°FCOMFORTSTAR: Beats 48%Mitsubishi Electric: Beats 55%
- Winter-long heating efficiencyHSPF2COMFORTSTAR: Beats 53%Mitsubishi Electric: Beats 67%
- Summer-long cooling efficiencySEER2COMFORTSTAR: Beats 47%Mitsubishi Electric: Beats 63%
- Hot-day cooling efficiencyEER2COMFORTSTAR: Beats 45%Mitsubishi Electric: Beats 61%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- COMFORTSTAR
- 50%
- Mitsubishi Electric
- 81%
Xcel CC
- COMFORTSTAR
- 46%
- Mitsubishi Electric
- 67%
CEE Advanced
- COMFORTSTAR
- 1%
- Mitsubishi Electric
- 10%
ENERGY STAR CC
- COMFORTSTAR
- 27%
- Mitsubishi Electric
- 66%
Top cold-climate picks, ducted 3.5 to 4.5 tons
Showing Ducted, 3.5 to 4.5 tons (39,000 to 56,999 Btu/h cooling). What size is my system?
COMFORTSTAR
- 1CVH3-48-6SHCOMFORTSTAR4 tons · 47,000 Btu/h · DuctedKeeps 100% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 11.0 (HSPF2)
- Top 10%
- 2CVH3-60-6SHCOMFORTSTAR4.5 tons · 53,000 Btu/h · DuctedKeeps 87% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 87% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.7 (HSPF2)
- Top 10%
- 3CHF3-60DU(O)with ducted air handler CPA3H-60DU(I)COMFORTSTAR4.5 tons · 55,000 Btu/h · DuctedKeeps 89% of its heat at 5°FMeets Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 89% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.4 (HSPF2)
- Top 10%
Mitsubishi Electric
- 1MXZ-SM48NLHZ-**Mitsubishi Electric4 tons · 48,000 Btu/h · DuctedKeeps 100% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.5 (HSPF2)
- Top 10%
- 2MXZ-SM42NLHZ-**Mitsubishi Electric3.5 tons · 42,000 Btu/h · DuctedKeeps 100% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 11.0 (HSPF2)
- Top 10%
- 3MXZ-SM42NLHZ***Mitsubishi ElectricAlso listed as PUMY-HL42NKMU3.5 tons · 42,000 Btu/h · DuctedKeeps 100% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.86 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 10.0 (HSPF2)
- Great
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view