Skip to content

CONTINENTAL vs Hessaire: heat pump ratings compared

Against heat pumps of the same size and type, a typical CONTINENTAL model beats 64% and a typical Hessaire model 50%. CONTINENTAL rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

CONTINENTAL

64%

of similar heat pumps beaten by its typical model

Well above average

31 models listed

Hessaire

50%

of similar heat pumps beaten by its typical model

About average

14 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FCONTINENTAL: Beats 52%Hessaire: Beats 50%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FCONTINENTAL: Beats 69%Hessaire: Beats 55%
  • Winter-long heating efficiencyHSPF2CONTINENTAL: Beats 77%Hessaire: Beats 49%
  • Summer-long cooling efficiencySEER2CONTINENTAL: Beats 65%Hessaire: Beats 54%
  • Hot-day cooling efficiencyEER2CONTINENTAL: Beats 62%Hessaire: Beats 42%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    CONTINENTAL
    77%
    Hessaire
    93%
  • Xcel CC

    CONTINENTAL
    84%
    Hessaire
    71%
  • CEE Advanced

    CONTINENTAL
    0%
    Hessaire
    0%
  • ENERGY STAR CC

    CONTINENTAL
    84%
    Hessaire
    57%

All-around best, ducted 3.5 to 4.5 tons

CONTINENTAL

  1. 1WSEHV4860BA1-Cwith ducted air handler WPFX48A-CCONTINENTAL4 tons · 48,000 Btu/h · DuctedCold-climate pick, score 63.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    84% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    11.5 (EER2)
    Good
    67.9score / 100Heating 59 · Cooling 77
  2. 2WSCHV0048BA1-Cwith ducted air handler WECC60ABC1CONTINENTAL4 tons · 45,000 Btu/h · DuctedCold-climate pick, score 60.4Meets Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    85% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.85 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.0 (HSPF2)
    Good
    Cooling efficiency
    15.2 (SEER2)
    Below the middle
    Hot-day cooling
    10.0 (EER2)
    Below the middle
    46.0score / 100Heating 60 · Cooling 32
  3. 3WSCHV0060BA1-Cwith ducted air handler WECC60ABC1CONTINENTAL4.5 tons · 51,000 Btu/h · DuctedCold-climate pick, score 44.0Meets none of the standards tracked here
    Heat kept at 5°F
    77% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.78 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.1 (HSPF2)
    Good
    Cooling efficiency
    14.9 (SEER2)
    Below the middle
    Hot-day cooling
    8.5 (EER2)
    Below the middle
    31.3score / 100Heating 44 · Cooling 19

Hessaire

  1. 1HOC48Bwith ducted air handler HAH48BHessaire4 tons · 48,000 Btu/h · DuctedCold-climate pick, score 60.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    73% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    9.0 (HSPF2)
    Good
    Cooling efficiency
    18.0 (SEER2)
    Great
    Hot-day cooling
    10.0 (EER2)
    Below the middle
    55.2score / 100Heating 61 · Cooling 50
  2. 2HOC60Bwith ducted air handler HAH60BHessaire4.5 tons · 54,000 Btu/h · DuctedNot a cold-climate pick: keeps 66% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    67% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.95 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.5 (HSPF2)
    Good
    Cooling efficiency
    17.0 (SEER2)
    Good
    Hot-day cooling
    8.8 (EER2)
    Below the middle
    42.7score / 100Heating 50 · Cooling 36

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter