Skip to content

Convectair vs First Co.: heat pump ratings compared

Against heat pumps of the same size and type, a typical Convectair model beats 72% and a typical First Co. model 18%. Convectair rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Convectair

72%

of similar heat pumps beaten by its typical model

Well above average

8 models listed

First Co.

18%

of similar heat pumps beaten by its typical model

Well below average

25 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FConvectair: Beats 45%First Co.: Beats 39%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FConvectair: Beats 86%First Co.: Beats 20%
  • Winter-long heating efficiencyHSPF2Convectair: Beats 82%First Co.: Beats 8%
  • Summer-long cooling efficiencySEER2Convectair: Beats 69%First Co.: Beats 8%
  • Hot-day cooling efficiencyEER2Convectair: Beats 77%First Co.: Beats 17%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Convectair
    100%
    First Co.
    12%
  • Xcel CC

    Convectair
    100%
    First Co.
    16%
  • CEE Advanced

    Convectair
    0%
    First Co.
    0%
  • ENERGY STAR CC

    Convectair
    100%
    First Co.
    0%

All-around best, ducted 2 tons

Convectair

No ducted, 2 tons model from Convectair.

First Co.

  1. 1EVE24***DFirst Co.2 tons · 23,400 Btu/h · DuctedCold-climate pick, score 59.3Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    83% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    9.0 (HSPF2)
    Good
    Cooling efficiency
    16.0 (SEER2)
    Below the middle
    Hot-day cooling
    10.8 (EER2)
    Below the middle
    44.0score / 100Heating 59 · Cooling 29
  2. 224WHHPBAwith ducted air handler 37CLX(*,Q,W)First Co.2 tons · 23,000 Btu/h · DuctedNot a cold-climate pick: keeps 56% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    55% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Below the middle
    Winter efficiency
    6.8 (HSPF2)
    Below the middle
    Cooling efficiency
    13.5 (SEER2)
    Below the middle
    Hot-day cooling
    12.0 (EER2)
    Good
    30.3score / 100Heating 23 · Cooling 38
  3. 3EHE24***D***BFirst Co.Also listed as EHE24***E***B2 tons · 24,400 Btu/h · DuctedNot a cold-climate pick: keeps 51% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    51% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    6.3 (HSPF2)
    Below the middle
    Cooling efficiency
    11.9 (SEER2)
    Below the middle
    Hot-day cooling
    10.0 (EER2)
    Below the middle
    13.9score / 100Heating 23 · Cooling 5

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter