Skip to content

Custom Comfort vs TRUENORTH: heat pump ratings compared

Against heat pumps of the same size and type, a typical Custom Comfort model beats 65% and a typical TRUENORTH model 42%. Custom Comfort rates higher overall.

Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated

Custom Comfort

65%

of similar heat pumps beaten by its typical model

Well above average

20 models listed

TRUENORTH

42%

of similar heat pumps beaten by its typical model

Below average

19 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FCustom Comfort: Beats 51%TRUENORTH: Beats 37%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FCustom Comfort: Beats 83%TRUENORTH: Beats 59%
  • Winter-long heating efficiencyHSPF2Custom Comfort: Beats 84%TRUENORTH: Beats 47%
  • Summer-long cooling efficiencySEER2Custom Comfort: Beats 65%TRUENORTH: Beats 39%
  • Hot-day cooling efficiencyEER2Custom Comfort: Beats 51%TRUENORTH: Beats 33%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Custom Comfort
    75%
    TRUENORTH
    58%
  • Xcel CC

    Custom Comfort
    85%
    TRUENORTH
    68%
  • CEE Advanced

    Custom Comfort
    5%
    TRUENORTH
    0%
  • ENERGY STAR CC

    Custom Comfort
    100%
    TRUENORTH
    58%

All-around best, ducted 2.5 to 3 tons

Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?

Custom Comfort

  1. 1CCOXHAMZ327HPCustom Comfort2.5 tons · 27,000 Btu/h · DuctedCold-climate pick, score 80.4Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    101% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Top 10%
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    11.8 (EER2)
    Great
    81.9score / 100Heating 80 · Cooling 83
  2. 2CCOXHAMZ436HPCustom Comfort3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 64.0Meets none of the standards tracked here
    Heat kept at 5°F
    89% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.70 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.0 (HSPF2)
    Top 10%
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    11.7 (EER2)
    Good
    71.4score / 100Heating 64 · Cooling 79
  3. 3CCOXHASZ36CHPwith ducted air handler CCOXHASD36Custom Comfort3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 80.0Meets ENERGY STAR CC
    Heat kept at 5°F
    86% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.98 (COP at 5°F)
    Good
    Winter efficiency
    11.0 (HSPF2)
    Top 10%
    Cooling efficiency
    16.5 (SEER2)
    Good
    Hot-day cooling
    9.0 (EER2)
    Below the middle
    58.4score / 100Heating 80 · Cooling 37

TRUENORTH

  1. 1WLWHD(30)ND3MOTRUENORTH2.5 tons · 28,400 Btu/h · DuctedCold-climate pick, score 54.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    89% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.1 (HSPF2)
    Below the middle
    Cooling efficiency
    16.0 (SEER2)
    Good
    Hot-day cooling
    11.0 (EER2)
    Below the middle
    53.0score / 100Heating 55 · Cooling 51
  2. 2WLWHD(42)ND3MOTRUENORTH3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 52.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    81% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.84 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.1 (HSPF2)
    Below the middle
    Cooling efficiency
    16.0 (SEER2)
    Good
    Hot-day cooling
    11.0 (EER2)
    Below the middle
    51.8score / 100Heating 52 · Cooling 51
  3. 3WLWHD(36)ND3MOTRUENORTH3 tons · 34,000 Btu/h · DuctedCold-climate pick, score 50.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    83% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.1 (HSPF2)
    Below the middle
    Cooling efficiency
    16.0 (SEER2)
    Good
    Hot-day cooling
    11.0 (EER2)
    Below the middle
    51.1score / 100Heating 51 · Cooling 51

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter