Skip to content

Daikin vs Midea: heat pump ratings compared

Against heat pumps of the same size and type, a typical Daikin model beats 50% and a typical Midea model 59%. Midea rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Daikin

50%

of similar heat pumps beaten by its typical model

About average

394 models listed

Midea

59%

of similar heat pumps beaten by its typical model

Above average

546 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FDaikin: Beats 46%Midea: Beats 59%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FDaikin: Beats 48%Midea: Beats 56%
  • Winter-long heating efficiencyHSPF2Daikin: Beats 38%Midea: Beats 66%
  • Summer-long cooling efficiencySEER2Daikin: Beats 45%Midea: Beats 61%
  • Hot-day cooling efficiencyEER2Daikin: Beats 54%Midea: Beats 54%

Average (50%)Dashed outline: the other brand, for comparison

Want ranks, distributions per size class and cold-weather curves? Switch to Advanced

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Daikin
    38%
    Midea
    76%
  • Xcel CC

    Daikin
    30%
    Midea
    70%
  • CEE Advanced

    Daikin
    2%
    Midea
    3%
  • ENERGY STAR CC

    Daikin
    17%
    Midea
    64%

All-around best, ducted 3.5–4.5 tons

Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.

Daikin

  1. 1DPSH04BAPB2****E35**0*DaikinAlso listed as DPSH04BAPB3****E35**0, DPSH04BAPB4****E35**0, DPSH04BAPB5****E35**04 tons · 46,000 Btu/h · DuctedCold-climate pick, score 68.2Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    99% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.94 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.8 (HSPF2)
    Good
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    12.1 (EER2)
    Top 10%
    79.2score / 100Heating 68 · Cooling 90
  2. 2DPSH04BAPB2****E31**0*DaikinAlso listed as DPSH04BAPB3****E31**0, DPSH04BAPB4****E31**0, DPSH04BAPB5****E31**04 tons · 46,000 Btu/h · DuctedCold-climate pick, score 63.9Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    96% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.88 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.7 (HSPF2)
    Good
    Cooling efficiency
    18.7 (SEER2)
    Great
    Hot-day cooling
    11.8 (EER2)
    Great
    73.4score / 100Heating 64 · Cooling 83
  3. 3DH7TCA4810A*with ducted air handler L(E,G)M48IDDaikin3.5 tons · 44,500 Btu/h · DuctedNot a cold-climate pick: keeps 61% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    62% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.68 (COP at 5°F)
    Top 10%
    Winter efficiency
    8.1 (HSPF2)
    Good
    Cooling efficiency
    17.0 (SEER2)
    Good
    Hot-day cooling
    12.5 (EER2)
    Top 10%
    71.0score / 100Heating 61 · Cooling 81

Midea

  1. 1D5CMRAH48FAKMideaAlso sold as MDV M6OE30-48HFN10-M1D, MDV M6OE30-48HFN10-M1; also listed as 37MGRAQ48FA34 tons · 45,000 Btu/h · DuctedCold-climate pick, score 77.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    81% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    10.6 (HSPF2)
    Top 10%
    Cooling efficiency
    20.5 (SEER2)
    Top 10%
    Hot-day cooling
    12.0 (EER2)
    Great
    85.7score / 100Heating 78 · Cooling 94
  2. 2MOVA-60HDN10-M20Gwith ducted air handler MVME48C2MN10TAMideaAlso listed as MOVC-60HDN10-M20G4 tons · 48,500 Btu/h · DuctedCold-climate pick, score 83.9Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    85.6score / 100Heating 84 · Cooling 87
  3. 3MO6EX-H48B-2AMideaAlso sold as MDV M6OE30-48HFN10-M1D-D, CTMorley MOU-5B48G-2, CTMorley MOU-6B48G-2; also listed as M6OE30-48HFN10-M1P4 tons · 45,000 Btu/h · DuctedCold-climate pick, score 77.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    81% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    10.6 (HSPF2)
    Top 10%
    Cooling efficiency
    20.4 (SEER2)
    Top 10%
    Hot-day cooling
    12.0 (EER2)
    Great
    85.1score / 100Heating 78 · Cooling 92

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.

Open the advanced view