Skip to content

DIYCOOL vs Nortek Global HVAC: heat pump ratings compared

Against heat pumps of the same size and type, a typical DIYCOOL model beats 55% and a typical Nortek Global HVAC model 32%. DIYCOOL rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

DIYCOOL

55%

of similar heat pumps beaten by its typical model

About average

24 models listed

Nortek Global HVAC

32%

of similar heat pumps beaten by its typical model

Well below average

109 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FDIYCOOL: Beats 53%Nortek Global HVAC: Beats 24%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FDIYCOOL: Beats 52%Nortek Global HVAC: Beats 28%
  • Winter-long heating efficiencyHSPF2DIYCOOL: Beats 63%Nortek Global HVAC: Beats 28%
  • Summer-long cooling efficiencySEER2DIYCOOL: Beats 60%Nortek Global HVAC: Beats 32%
  • Hot-day cooling efficiencyEER2DIYCOOL: Beats 46%Nortek Global HVAC: Beats 42%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    DIYCOOL
    79%
    Nortek Global HVAC
    28%
  • Xcel CC

    DIYCOOL
    71%
    Nortek Global HVAC
    20%
  • CEE Advanced

    DIYCOOL
    4%
    Nortek Global HVAC
    2%
  • ENERGY STAR CC

    DIYCOOL
    75%
    Nortek Global HVAC
    11%

All-around best, ducted 2 tons

DIYCOOL

  1. 1ACIQ-24-HP32with ducted air handler ACIQ-24-AH32DIYCOOL2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 76.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    18.0 (SEER2)
    Good
    Hot-day cooling
    12.0 (EER2)
    Good
    68.6score / 100Heating 76 · Cooling 61
  2. 2EZ-27Z-M3BDIYCOOL2 tons · 26,000 Btu/h · DuctedCold-climate pick, score 59.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    71% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    9.5 (HSPF2)
    Good
    Cooling efficiency
    20.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Good
    68.4score / 100Heating 59 · Cooling 78
  3. 3EZ-24-HPBwith ducted air handler EZ-24-AHBDIYCOOL2 tons · 23,000 Btu/h · DuctedCold-climate pick, score 66.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    90% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.87 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    18.4 (SEER2)
    Good
    Hot-day cooling
    11.7 (EER2)
    Below the middle
    61.3score / 100Heating 66 · Cooling 56

Nortek Global HVAC

  1. 1DXH24FMK3IHNortek Global HVAC (sold as Gibson)2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 48.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    90% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.86 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.1 (HSPF2)
    Below the middle
    Cooling efficiency
    18.0 (SEER2)
    Good
    Hot-day cooling
    12.0 (EER2)
    Good
    55.0score / 100Heating 49 · Cooling 61
  2. 2SH4BF5M2SX24Kwith ducted air handler B65VMMX24K-BNortek Global HVAC (sold as Nortek Global Hvac Llc)Also sold as Frigidaire FSH4BF5M2SX24K, Maytag PSH4BF5M2SX24K2 tons · 24,000 Btu/h · DuctedNot a cold-climate pick: keeps 48% of its heat at 5°FMeets CEE 2025
    Heat kept at 5°F
    48% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.75 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.0 (HSPF2)
    Below the middle
    Cooling efficiency
    16.0 (SEER2)
    Below the middle
    Hot-day cooling
    11.7 (EER2)
    Below the middle
    30.9score / 100Heating 20 · Cooling 42
  3. 3SH4ME5M1SP24Kwith indoor coil C75B(A,H)MX24C*B and furnace MG3P-054U1AABNortek Global HVAC (sold as Nordyne)Also sold as Intertherm HSH4ME5M1SP24K2 tons · 23,400 Btu/h · DuctedNot a cold-climate pick: keeps 50% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    51% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.75 (COP at 5°F)
    Below the middle
    Winter efficiency
    7.5 (HSPF2)
    Below the middle
    Cooling efficiency
    14.3 (SEER2)
    Below the middle
    Hot-day cooling
    11.0 (EER2)
    Below the middle
    19.0score / 100Heating 17 · Cooling 21

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter