Skip to content

DUOHOME vs Nutech: heat pump ratings compared

Against heat pumps of the same size and type, a typical DUOHOME model beats 58% and a typical Nutech model 54%. DUOHOME rates slightly higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

DUOHOME

58%

of similar heat pumps beaten by its typical model

Above average

50 models listed

Nutech

54%

of similar heat pumps beaten by its typical model

About average

50 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FDUOHOME: Beats 62%Nutech: Beats 57%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FDUOHOME: Beats 50%Nutech: Beats 45%
  • Winter-long heating efficiencyHSPF2DUOHOME: Beats 62%Nutech: Beats 57%
  • Summer-long cooling efficiencySEER2DUOHOME: Beats 60%Nutech: Beats 69%
  • Hot-day cooling efficiencyEER2DUOHOME: Beats 51%Nutech: Beats 40%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    DUOHOME
    76%
    Nutech
    70%
  • Xcel CC

    DUOHOME
    66%
    Nutech
    48%
  • CEE Advanced

    DUOHOME
    0%
    Nutech
    0%
  • ENERGY STAR CC

    DUOHOME
    8%
    Nutech
    0%

All-around best, ductless 2.5 to 3 tons

DUOHOME

  1. 1D5OD30-36HFN10-M1-DDUOHOMEAlso listed as D5OD30-36HFN10-M1D-D3 tons · 35,000 Btu/h · DuctlessCold-climate pick, score 48.2Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    70% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Good
    Cooling efficiency
    23.1 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Good
    59.3score / 100Heating 48 · Cooling 70
  2. 2DOD30-36HFN10-M2with ductless indoor unit DCD-36HRFN10-M2-DDUOHOME3 tons · 36,000 Btu/h · DuctlessCold-climate pick, score 63.6Meets Xcel CC
    Heat kept at 5°F
    70% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.20 (COP at 5°F)
    Top 10%
    Winter efficiency
    10.3 (HSPF2)
    Good
    Cooling efficiency
    20.0 (SEER2)
    Below the middle
    Hot-day cooling
    9.6 (EER2)
    Below the middle
    45.0score / 100Heating 64 · Cooling 27
  3. 3DOD30-36HFN10-M1Ewith ductless indoor unit DSAG11FM-36HRFN10-M1E-DDUOHOME3 tons · 36,000 Btu/h · DuctlessNot a cold-climate pick: keeps 66% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    67% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.02 (COP at 5°F)
    Great
    Winter efficiency
    9.1 (HSPF2)
    Below the middle
    Cooling efficiency
    19.5 (SEER2)
    Below the middle
    Hot-day cooling
    9.3 (EER2)
    Below the middle
    27.2score / 100Heating 41 · Cooling 14

Nutech

  1. 1N5OD30-36HFN10-M1D-DNutech3 tons · 35,000 Btu/h · DuctlessCold-climate pick, score 48.2Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    70% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Good
    Cooling efficiency
    23.1 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Good
    59.3score / 100Heating 48 · Cooling 70
  2. 2NOD30-30HFN10-230with ductless indoor unit NSAG11F-30HRFN10-230Nutech2.5 tons · 30,000 Btu/h · DuctlessNot a cold-climate pick: keeps 66% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    67% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.94 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.0 (HSPF2)
    Below the middle
    Cooling efficiency
    22.4 (SEER2)
    Good
    Hot-day cooling
    12.0 (EER2)
    Good
    41.0score / 100Heating 21 · Cooling 61
  3. 3NOD30-36HFN10-230with ductless indoor unit NSAG11FM-36HRFN10-230Nutech3 tons · 36,000 Btu/h · DuctlessNot a cold-climate pick: keeps 66% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    67% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.02 (COP at 5°F)
    Great
    Winter efficiency
    9.1 (HSPF2)
    Below the middle
    Cooling efficiency
    19.5 (SEER2)
    Below the middle
    Hot-day cooling
    9.4 (EER2)
    Below the middle
    27.6score / 100Heating 41 · Cooling 14

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter