Durastar vs TGM: heat pump ratings compared
Against heat pumps of the same size and type, a typical Durastar model beats 52% and a typical TGM model 46%. Durastar rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Durastar
52%
of similar heat pumps beaten by its typical model
About average78 models listed
TGM
46%
of similar heat pumps beaten by its typical model
About average77 models listed
- Efficiency on a 5°F dayCOP at 5°FDurastar: Beats 63%TGM: Beats 48%
- Heating power kept at 5°FCapacity at 5°F vs 47°FDurastar: Beats 51%TGM: Beats 43%
- Winter-long heating efficiencyHSPF2Durastar: Beats 53%TGM: Beats 41%
- Summer-long cooling efficiencySEER2Durastar: Beats 47%TGM: Beats 45%
- Hot-day cooling efficiencyEER2Durastar: Beats 46%TGM: Beats 43%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- Durastar
- 55%
- TGM
- 58%
Xcel CC
- Durastar
- 50%
- TGM
- 55%
CEE Advanced
- Durastar
- 4%
- TGM
- 1%
ENERGY STAR CC
- Durastar
- 47%
- TGM
- 21%
Top cold-climate picks, ducted 3.5 to 4.5 tons
Showing Ducted, 3.5 to 4.5 tons (39,000 to 56,999 Btu/h cooling). What size is my system?
Durastar
- 1DRA6H48M2ADurastar4 tons · 47,000 Btu/h · DuctedKeeps 100% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 11.0 (HSPF2)
- Top 10%
- 2DRA6H55M2ADurastar4.5 tons · 53,000 Btu/h · DuctedKeeps 87% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 87% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.7 (HSPF2)
- Top 10%
- 3DRA6U48M2ADurastar4 tons · 45,000 Btu/h · DuctedKeeps 81% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 81% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.6 (HSPF2)
- Top 10%
TGM
- 1OTV18HN048Awith ducted air handler OTA18C006ATGMAlso listed as OTV18HN060A4 tons · 47,000 Btu/h · DuctedKeeps 72% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 72% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.30 (COP at 5°F)
- Great
- Seasonal efficiency
- 9.2 (HSPF2)
- Great
- 2MRS5VHT48ASwith ducted air handler MFC5VHT48STGM4 tons · 48,000 Btu/h · DuctedKeeps 76% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 76% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 9.8 (HSPF2)
- Great
- 3CTV520HN060Awith ducted air handler CTA520C060ATGM4.5 tons · 55,500 Btu/h · DuctedKeeps 75% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 75% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Seasonal efficiency
- 8.6 (HSPF2)
- Good
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.