Both views use the same certified data. This device remembers your choice.
Dynoaire vs THERMOFLUX: heat pump ratings compared
Against heat pumps of the same size and type, a typical Dynoaire model beats 18% and a typical THERMOFLUX model 61%. THERMOFLUX rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Dynoaire
18%
of similar heat pumps beaten by its typical model
Well below average22 models listed
THERMOFLUX
61%
of similar heat pumps beaten by its typical model
Well above average21 models listed
- Efficiency on a 5°F dayCOP at 5°FDynoaire: Beats 19%THERMOFLUX: Beats 33%
- Heating power kept at 5°FCapacity at 5°F vs 47°FDynoaire: Beats 7%THERMOFLUX: Beats 73%
- Winter-long heating efficiencyHSPF2Dynoaire: Beats 21%THERMOFLUX: Beats 64%
- Summer-long cooling efficiencySEER2Dynoaire: Beats 27%THERMOFLUX: Beats 74%
- Hot-day cooling efficiencyEER2Dynoaire: Beats 41%THERMOFLUX: Beats 58%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- Dynoaire
- 0%
- THERMOFLUX
- 76%
Xcel CC
- Dynoaire
- 0%
- THERMOFLUX
- 76%
CEE Advanced
- Dynoaire
- 0%
- THERMOFLUX
- 0%
ENERGY STAR CC
- Dynoaire
- 0%
- THERMOFLUX
- 57%
All-around best, ducted 2.5 to 3 tons
Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling). What size is my system?
Dynoaire
- 1DPHP4042A1FH000ADynoaire3 tons · 38,500 Btu/h · DuctedNot a cold-climate pick: keeps 42% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 43% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.86 (COP at 5°F)
- Below the middle
- Winter efficiency
- 6.7 (HSPF2)
- Below the middle
- Cooling efficiency
- 13.4 (SEER2)
- Below the middle
- Hot-day cooling
- 11.4 (EER2)
- Good
- 2DPHP4030A1FH000ADynoaire2.5 tons · 28,200 Btu/h · DuctedNot a cold-climate pick: keeps 37% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 38% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.64 (COP at 5°F)
- Below the middle
- Winter efficiency
- 6.7 (HSPF2)
- Below the middle
- Cooling efficiency
- 13.4 (SEER2)
- Below the middle
- Hot-day cooling
- 11.5 (EER2)
- Good
- 3DPHP4036A1FH000ADynoaire2.5 tons · 32,000 Btu/h · DuctedNot a cold-climate pick: keeps 36% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 37% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.58 (COP at 5°F)
- Below the middle
- Winter efficiency
- 6.7 (HSPF2)
- Below the middle
- Cooling efficiency
- 13.4 (SEER2)
- Below the middle
- Hot-day cooling
- 11.2 (EER2)
- Below the middle
THERMOFLUX
- 1TMFS36HDI2NAJ0H26with ducted air handler TMFS36IDI2NAJ0H26THERMOFLUX3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 64.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.85 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.5 (HSPF2)
- Great
- Cooling efficiency
- 18.0 (SEER2)
- Good
- Hot-day cooling
- 11.0 (EER2)
- Below the middle
- 2TMFT36TDI2NAF2H26with ducted air handler TMFT36IDI2NAF2H26THERMOFLUX3 tons · 36,000 Btu/h · DuctedNot a cold-climate pick: keeps 63% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 64% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 8.1 (HSPF2)
- Below the middle
- Cooling efficiency
- 15.2 (SEER2)
- Below the middle
- Hot-day cooling
- 9.0 (EER2)
- Below the middle
- 3THH36TDI2NAF2H26with ducted air handler THH36IDI2NAF2H26THERMOFLUX3 tons · 36,000 Btu/h · DuctedNot a cold-climate pick: keeps 63% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 64% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 8.1 (HSPF2)
- Below the middle
- Cooling efficiency
- 15.2 (SEER2)
- Below the middle
- Hot-day cooling
- 9.0 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view