Skip to content

Everwell vs Upstreman: heat pump ratings compared

Against heat pumps of the same size and type, a typical Everwell model beats 28% and a typical Upstreman model 30%. Upstreman rates slightly higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Everwell

28%

of similar heat pumps beaten by its typical model

Well below average

19 models listed

Upstreman

30%

of similar heat pumps beaten by its typical model

Well below average

19 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FEverwell: Beats 40%Upstreman: Beats 58%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FEverwell: Beats 20%Upstreman: Beats 13%
  • Winter-long heating efficiencyHSPF2Everwell: Beats 21%Upstreman: Beats 16%
  • Summer-long cooling efficiencySEER2Everwell: Beats 21%Upstreman: Beats 34%
  • Hot-day cooling efficiencyEER2Everwell: Beats 27%Upstreman: Beats 27%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Everwell
    11%
    Upstreman
    58%
  • Xcel CC

    Everwell
    11%
    Upstreman
    21%
  • CEE Advanced

    Everwell
    0%
    Upstreman
    0%
  • ENERGY STAR CC

    Everwell
    0%
    Upstreman
    0%

All-around best, ductless up to 1.5 tons

Everwell

  1. 1MKTH1215C-17with ductless indoor unit MKTH1215E-17Everwell1 ton · 11,500 Btu/h · DuctlessNot a cold-climate pick: keeps 69% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    70% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Below the middle
    Cooling efficiency
    17.0 (SEER2)
    Below the middle
    Hot-day cooling
    9.5 (EER2)
    Below the middle
    23.4score / 100Heating 38 · Cooling 9
  2. 2MKTH1825C-17with ductless indoor unit MKTH1825E-17Everwell1.5 tons · 17,000 Btu/h · DuctlessNot a cold-climate pick: keeps 57% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    58% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.5 (HSPF2)
    Below the middle
    Cooling efficiency
    17.0 (SEER2)
    Below the middle
    Hot-day cooling
    9.5 (EER2)
    Below the middle
    10.6score / 100Heating 13 · Cooling 9
  3. 3MKTH1225C-17with ductless indoor unit MKTH1225E-17Everwell1 ton · 11,500 Btu/h · DuctlessNot a cold-climate pick: keeps 60% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    61% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.75 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.5 (HSPF2)
    Below the middle
    Cooling efficiency
    17.0 (SEER2)
    Below the middle
    Hot-day cooling
    9.5 (EER2)
    Below the middle
    8.9score / 100Heating 9 · Cooling 9

Upstreman

  1. 1I20-230ODUUpstreman1.5 tons · 20,000 Btu/h · DuctlessCold-climate pick, score 46.4Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    70% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    9.5 (HSPF2)
    Below the middle
    Cooling efficiency
    23.0 (SEER2)
    Good
    Hot-day cooling
    11.2 (EER2)
    Below the middle
    49.6score / 100Heating 46 · Cooling 53
  2. 2I12-115Wwith ductless indoor unit I12-115GUpstremanAlso listed as UI12-115W1 ton · 12,000 Btu/h · DuctlessNot a cold-climate pick: keeps 56% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    57% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    8.5 (HSPF2)
    Below the middle
    Cooling efficiency
    20.0 (SEER2)
    Below the middle
    Hot-day cooling
    11.3 (EER2)
    Below the middle
    31.0score / 100Heating 27 · Cooling 35
  3. 3IY18-230Wwith ductless indoor unit IY18-230GUpstremanAlso listed as IY18-230W-11.5 tons · 17,100 Btu/h · DuctlessNot a cold-climate pick: keeps 55% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    55% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.22 (COP at 5°F)
    Great
    Winter efficiency
    8.2 (HSPF2)
    Below the middle
    Cooling efficiency
    18.1 (SEER2)
    Below the middle
    Hot-day cooling
    11.6 (EER2)
    Below the middle
    29.8score / 100Heating 32 · Cooling 27

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter