Both views use the same certified data. This device remembers your choice.
First Co. vs NAPOLEON: heat pump ratings compared
Against heat pumps of the same size and type, a typical First Co. model beats 17% and a typical NAPOLEON model 65%. NAPOLEON rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
First Co.
17%
of similar heat pumps beaten by its typical model
Well below average25 models listed
NAPOLEON
65%
of similar heat pumps beaten by its typical model
Well above average25 models listed
- Efficiency on a 5°F dayCOP at 5°FFirst Co.: Beats 39%NAPOLEON: Beats 57%
- Heating power kept at 5°FCapacity at 5°F vs 47°FFirst Co.: Beats 20%NAPOLEON: Beats 71%
- Winter-long heating efficiencyHSPF2First Co.: Beats 8%NAPOLEON: Beats 79%
- Summer-long cooling efficiencySEER2First Co.: Beats 8%NAPOLEON: Beats 64%
- Hot-day cooling efficiencyEER2First Co.: Beats 17%NAPOLEON: Beats 60%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- First Co.
- 12%
- NAPOLEON
- 76%
Xcel CC
- First Co.
- 16%
- NAPOLEON
- 80%
CEE Advanced
- First Co.
- 0%
- NAPOLEON
- 4%
ENERGY STAR CC
- First Co.
- 0%
- NAPOLEON
- 72%
All-around best, ducted up to 1.5 tons
Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
First Co.
- 1EVE12***DFirst Co.1 ton · 11,800 Btu/h · DuctedCold-climate pick, score 60.4Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 85% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Great
- Winter efficiency
- 9.0 (HSPF2)
- Below the middle
- Cooling efficiency
- 17.0 (SEER2)
- Good
- Hot-day cooling
- 13.0 (EER2)
- Great
- 2EVE18***DFirst Co.1.5 tons · 17,300 Btu/h · DuctedCold-climate pick, score 55.8Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 80% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 9.0 (HSPF2)
- Below the middle
- Cooling efficiency
- 16.0 (SEER2)
- Good
- Hot-day cooling
- 11.0 (EER2)
- Below the middle
- 318WHHPBAwith ducted air handler 37CLX(*,Q,W)First Co.1.5 tons · 18,500 Btu/h · DuctedNot a cold-climate pick: keeps 44% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 42% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.50 (COP at 5°F)
- Below the middle
- Winter efficiency
- 6.8 (HSPF2)
- Below the middle
- Cooling efficiency
- 14.2 (SEER2)
- Below the middle
- Hot-day cooling
- 12.5 (EER2)
- Great
NAPOLEON
- 1NDHAS26BA-09-Owith ducted air handler NDHASHDBB-09NAPOLEON1 ton · 9,000 Btu/h · DuctedCold-climate pick, score 80.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 120% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.85 (COP at 5°F)
- Below the middle
- Winter efficiency
- 13.8 (HSPF2)
- Top 10%
- Cooling efficiency
- 20.5 (SEER2)
- Top 10%
- Hot-day cooling
- 14.0 (EER2)
- Top 10%
- 2NDHAS22BA-18-Owith ducted air handler NDHASHDBB-18NAPOLEON1.5 tons · 17,500 Btu/h · DuctedCold-climate pick, score 70.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 71% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.41 (COP at 5°F)
- Top 10%
- Winter efficiency
- 11.3 (HSPF2)
- Top 10%
- Cooling efficiency
- 20.0 (SEER2)
- Great
- Hot-day cooling
- 13.3 (EER2)
- Top 10%
- 3NDHAMBB-18-ONAPOLEON1.5 tons · 19,000 Btu/h · DuctedCold-climate pick, score 71.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 90% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 20.0 (SEER2)
- Great
- Hot-day cooling
- 13.0 (EER2)
- Great
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view