First Co. vs WILLIS: heat pump ratings compared
Against heat pumps of the same size and type, a typical First Co. model beats 18% and a typical WILLIS model 63%. WILLIS rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
First Co.
18%
of similar heat pumps beaten by its typical model
Well below average25 models listed
WILLIS
63%
of similar heat pumps beaten by its typical model
Well above average29 models listed
- Efficiency on a 5°F dayCOP at 5°FFirst Co.: Beats 39%WILLIS: Beats 45%
- Heating power kept at 5°FCapacity at 5°F vs 47°FFirst Co.: Beats 20%WILLIS: Beats 72%
- Winter-long heating efficiencyHSPF2First Co.: Beats 8%WILLIS: Beats 51%
- Summer-long cooling efficiencySEER2First Co.: Beats 8%WILLIS: Beats 69%
- Hot-day cooling efficiencyEER2First Co.: Beats 17%WILLIS: Beats 69%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- First Co.
- 12%
- WILLIS
- 97%
Xcel CC
- First Co.
- 16%
- WILLIS
- 97%
CEE Advanced
- First Co.
- 0%
- WILLIS
- 10%
ENERGY STAR CC
- First Co.
- 0%
- WILLIS
- 86%
All-around best, ducted 2 tons
Showing Ducted, 2 tons (21,000 to 26,999 Btu/h cooling). What size is my system?
First Co.
- 1EVE24***DFirst Co.2 tons · 23,400 Btu/h · DuctedCold-climate pick, score 59.3Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 83% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 9.0 (HSPF2)
- Good
- Cooling efficiency
- 16.0 (SEER2)
- Below the middle
- Hot-day cooling
- 10.8 (EER2)
- Below the middle
- 224WHHPBAwith ducted air handler 37CLX(*,Q,W)First Co.2 tons · 23,000 Btu/h · DuctedNot a cold-climate pick: keeps 56% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 55% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Winter efficiency
- 6.8 (HSPF2)
- Below the middle
- Cooling efficiency
- 13.5 (SEER2)
- Below the middle
- Hot-day cooling
- 12.0 (EER2)
- Good
- 3EHE24***D***BFirst Co.Also listed as EHE24***E***B2 tons · 24,400 Btu/h · DuctedNot a cold-climate pick: keeps 51% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 51% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 6.3 (HSPF2)
- Below the middle
- Cooling efficiency
- 11.9 (SEER2)
- Below the middle
- Hot-day cooling
- 10.0 (EER2)
- Below the middle
WILLIS
- 1AUHW24KR32-Owith ducted air handler WHEDT24KWILLIS2 tons · 22,000 Btu/h · DuctedCold-climate pick, score 51.6Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 88% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.0 (HSPF2)
- Good
- Cooling efficiency
- 22.0 (SEER2)
- Top 10%
- Hot-day cooling
- 12.5 (EER2)
- Great
- 2FLEX24KUHR32with ducted air handler FLEXAH24KR32WILLIS2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 76.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 18.0 (SEER2)
- Good
- Hot-day cooling
- 12.0 (EER2)
- Good
- 3FLEX36KUHR32with ducted air handler FLEXAH24KR32WILLIS2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 77.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 96% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 18.0 (SEER2)
- Good
- Hot-day cooling
- 12.0 (EER2)
- Good
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view