Skip to content

Friedrich vs Lennox: heat pump ratings compared

Against heat pumps of the same size and type, a typical Friedrich model beats 39% and a typical Lennox model 48%. Lennox rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Friedrich

39%

of similar heat pumps beaten by its typical model

Well below average

188 models listed

Lennox

48%

of similar heat pumps beaten by its typical model

About average

331 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FFriedrich: Beats 46%Lennox: Beats 46%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FFriedrich: Beats 36%Lennox: Beats 43%
  • Winter-long heating efficiencyHSPF2Friedrich: Beats 31%Lennox: Beats 44%
  • Summer-long cooling efficiencySEER2Friedrich: Beats 34%Lennox: Beats 45%
  • Hot-day cooling efficiencyEER2Friedrich: Beats 37%Lennox: Beats 57%

Average (50%)Dashed outline: the other brand, for comparison

Want ranks, distributions per size class and cold-weather curves? Switch to Advanced

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Friedrich
    27%
    Lennox
    44%
  • Xcel CC

    Friedrich
    21%
    Lennox
    36%
  • CEE Advanced

    Friedrich
    1%
    Lennox
    3%
  • ENERGY STAR CC

    Friedrich
    22%
    Lennox
    30%

All-around best, ducted 5 tons and up

Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.

Friedrich

  1. 1FRP17AY60AJVCwith ducted air handler RH2TY6024STANNFriedrich5 tons · 57,000 Btu/h · DuctedCold-climate pick, score 77.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    78% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    17.0 (SEER2)
    Great
    Hot-day cooling
    11.0 (EER2)
    Good
    70.3score / 100Heating 77 · Cooling 63
  2. 2FRP15AY60AJ2Nwith ducted air handler FRH2TY6024STANNFriedrichAlso listed as FWP15AY60AJ2N5 tons · 57,000 Btu/h · DuctedNot a cold-climate pick: keeps 52% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    50% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    7.8 (HSPF2)
    Good
    Cooling efficiency
    15.2 (SEER2)
    Below the middle
    Hot-day cooling
    11.7 (EER2)
    Good
    56.6score / 100Heating 55 · Cooling 58
  3. 3FWP14AY60AJ2Nwith ducted air handler FRH2TY6024STANNFriedrichAlso listed as FRP14AY60AJ2N5 tons · 57,000 Btu/h · DuctedNot a cold-climate pick: keeps 52% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    47% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Below the middle
    Winter efficiency
    7.8 (HSPF2)
    Good
    Cooling efficiency
    15.2 (SEER2)
    Below the middle
    Hot-day cooling
    11.7 (EER2)
    Good
    52.4score / 100Heating 47 · Cooling 58

Lennox

  1. 1VPD060H6M-5PLennox5 tons · 60,000 Btu/h · DuctedCold-climate pick, score 83.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    85% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.04 (COP at 5°F)
    Good
    Winter efficiency
    10.5 (HSPF2)
    Top 10%
    Cooling efficiency
    19.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Good
    84.6score / 100Heating 84 · Cooling 85
  2. 2SHH060U5E**GLennoxAlso listed as SHH060U5E**J, SDH060U5E**G, SDH060U5E**J5 tons · 57,000 Btu/h · DuctedNot a cold-climate pick: keeps 55% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    55% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.20 (COP at 5°F)
    Great
    Winter efficiency
    7.6 (HSPF2)
    Good
    Cooling efficiency
    17.0 (SEER2)
    Great
    Hot-day cooling
    11.2 (EER2)
    Good
    67.3score / 100Heating 68 · Cooling 67
  3. 3ML14KP1-060-230A**with ducted air handler CBK45UHVT-060-230-LennoxAlso sold as Allied 7HP14F60P-**A, Armstrong Air A7HP14F60P-**A, Comfort-Aire HSA1460S1-**A; also listed as EL16KP1-060-230A, ML14KP1-060-233A, ML14KP1-060-463A5 tons · 57,000 Btu/h · DuctedNot a cold-climate pick: keeps 62% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    54% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.24 (COP at 5°F)
    Top 10%
    Winter efficiency
    8.1 (HSPF2)
    Good
    Cooling efficiency
    14.7 (SEER2)
    Below the middle
    Hot-day cooling
    12.2 (EER2)
    Top 10%
    66.7score / 100Heating 71 · Cooling 63

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.

Open the advanced view