Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Friedrich vs Rheem: heat pump ratings compared
Against heat pumps of the same size and type, a typical Friedrich model beats 46% and a typical Rheem model 54%. Rheem rates higher overall.
Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated
Friedrich
46%
of similar heat pumps beaten by its typical model
About average117 models listed
Rheem
54%
of similar heat pumps beaten by its typical model
About average291 models listed
- Efficiency on a 5°F dayCOP at 5°FFriedrich: Beats 58%Rheem: Beats 69%
- Heating power kept at 5°FCapacity at 5°F vs 47°FFriedrich: Beats 45%Rheem: Beats 59%
- Winter-long heating efficiencyHSPF2Friedrich: Beats 31%Rheem: Beats 49%
- Summer-long cooling efficiencySEER2Friedrich: Beats 36%Rheem: Beats 44%
- Hot-day cooling efficiencyEER2Friedrich: Beats 39%Rheem: Beats 46%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- Friedrich
- 38%
- Rheem
- 40%
Xcel CC
- Friedrich
- 32%
- Rheem
- 35%
CEE Advanced
- Friedrich
- 2%
- Rheem
- 6%
ENERGY STAR CC
- Friedrich
- 28%
- Rheem
- 16%
All-around best, ducted 2.5–3 tons
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Showing Ducted, 2.5–3 tons (27,000–38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?
Friedrich
- 1FRP18AZ36AJVCwith ducted air handler FRHMVZ6021SEACAFriedrich3 tons · 34,200 Btu/h · DuctedCold-climate pick, score 80.6Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 113% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Great
- Winter efficiency
- 8.5 (HSPF2)
- Good
- Cooling efficiency
- 20.0 (SEER2)
- Top 10%
- Hot-day cooling
- 12.5 (EER2)
- Top 10%
- 2FPHMR36A3AFriedrich2.5 tons · 32,000 Btu/h · DuctedCold-climate pick, score 69.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 113% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.84 (COP at 5°F)
- Below the middle
- Winter efficiency
- 8.9 (HSPF2)
- Good
- Cooling efficiency
- 19.5 (SEER2)
- Great
- Hot-day cooling
- 12.0 (EER2)
- Great
- 3RD17AZ36AJ3Nwith ducted air handler FRH2VZ3621MTANAFriedrich3 tons · 34,200 Btu/h · DuctedCold-climate pick, score 64.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 53% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.30 (COP at 5°F)
- Great
- Winter efficiency
- 8.5 (HSPF2)
- Good
- Cooling efficiency
- 19.0 (SEER2)
- Great
- Hot-day cooling
- 12.0 (EER2)
- Great
Rheem
- 1UP18AZ36AJVCwith indoor coil RCFZ6021SEAAM and furnace U802VA075317MRheem (sold as RUUD)3 tons · 34,200 Btu/h · DuctedCold-climate pick, score 80.7Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 126% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Great
- Winter efficiency
- 8.5 (HSPF2)
- Good
- Cooling efficiency
- 20.0 (SEER2)
- Top 10%
- Hot-day cooling
- 12.5 (EER2)
- Top 10%
- 2RP18AZ36AJVCwith indoor coil RCFZ6021SEAAM and furnace R802VA075317MRheemAlso sold as SURE SP18AZ36AJVC3 tons · 34,200 Btu/h · DuctedCold-climate pick, score 80.6Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 119% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Great
- Winter efficiency
- 8.5 (HSPF2)
- Good
- Cooling efficiency
- 20.0 (SEER2)
- Top 10%
- Hot-day cooling
- 12.5 (EER2)
- Top 10%
- 3MLP18AZ36AJVCwith ducted air handler MLHMVZ6021SEACARheem (sold as Mainline)3 tons · 34,200 Btu/h · DuctedCold-climate pick, score 80.6Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP
- Heat kept at 5°F
- 121% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Great
- Winter efficiency
- 8.5 (HSPF2)
- Good
- Cooling efficiency
- 18.0 (SEER2)
- Great
- Hot-day cooling
- 12.5 (EER2)
- Top 10%
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view