Skip to content

Friedrich vs York: heat pump ratings compared

Against heat pumps of the same size and type, a typical Friedrich model beats 39% and a typical York model 54%. York rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Friedrich

39%

of similar heat pumps beaten by its typical model

Well below average

188 models listed

York

54%

of similar heat pumps beaten by its typical model

About average

229 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FFriedrich: Beats 46%York: Beats 67%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FFriedrich: Beats 36%York: Beats 51%
  • Winter-long heating efficiencyHSPF2Friedrich: Beats 31%York: Beats 44%
  • Summer-long cooling efficiencySEER2Friedrich: Beats 34%York: Beats 40%
  • Hot-day cooling efficiencyEER2Friedrich: Beats 37%York: Beats 57%

Average (50%)Dashed outline: the other brand, for comparison

Want ranks, distributions per size class and cold-weather curves? Switch to Advanced

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Friedrich
    27%
    York
    53%
  • Xcel CC

    Friedrich
    21%
    York
    39%
  • CEE Advanced

    Friedrich
    1%
    York
    8%
  • ENERGY STAR CC

    Friedrich
    22%
    York
    35%

All-around best, ducted 5 tons and up

Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.

Friedrich

  1. 1FRP17AY60AJVCwith ducted air handler RH2TY6024STANNFriedrich5 tons · 57,000 Btu/h · DuctedCold-climate pick, score 77.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    78% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    17.0 (SEER2)
    Great
    Hot-day cooling
    11.0 (EER2)
    Good
    70.3score / 100Heating 77 · Cooling 63
  2. 2FRP15AY60AJ2Nwith ducted air handler FRH2TY6024STANNFriedrichAlso listed as FWP15AY60AJ2N5 tons · 57,000 Btu/h · DuctedNot a cold-climate pick: keeps 52% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    50% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    7.8 (HSPF2)
    Good
    Cooling efficiency
    15.2 (SEER2)
    Below the middle
    Hot-day cooling
    11.7 (EER2)
    Good
    56.6score / 100Heating 55 · Cooling 58
  3. 3FWP14AY60AJ2Nwith ducted air handler FRH2TY6024STANNFriedrichAlso listed as FRP14AY60AJ2N5 tons · 57,000 Btu/h · DuctedNot a cold-climate pick: keeps 52% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    47% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Below the middle
    Winter efficiency
    7.8 (HSPF2)
    Good
    Cooling efficiency
    15.2 (SEER2)
    Below the middle
    Hot-day cooling
    11.7 (EER2)
    Good
    52.4score / 100Heating 47 · Cooling 58

York

  1. 1PH9E60N00D21York (sold as Champion Heating and Cooling)5 tons · 57,000 Btu/h · DuctedCold-climate pick, score 63.4Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    70% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.85 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.0 (HSPF2)
    Good
    Cooling efficiency
    19.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.2 (EER2)
    Good
    70.1score / 100Heating 63 · Cooling 77
  2. 2XH460E2S11with ducted air handler JSC60D5CJ2SS1York (sold as Coleman)5 tons · 57,000 Btu/h · DuctedCold-climate pick, score 59.6Meets none of the standards tracked here
    Heat kept at 5°F
    55% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.28 (COP at 5°F)
    Top 10%
    Winter efficiency
    7.5 (HSPF2)
    Good
    Cooling efficiency
    14.3 (SEER2)
    Below the middle
    Hot-day cooling
    11.0 (EER2)
    Good
    53.8score / 100Heating 69 · Cooling 39
  3. 3PL5E60N00D21York (sold as Champion Heating and Cooling)5 tons · 57,000 Btu/h · DuctedCold-climate pick, score 59.7Meets ENERGY STAR CC
    Heat kept at 5°F
    70% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.5 (HSPF2)
    Good
    Cooling efficiency
    16.0 (SEER2)
    Good
    Hot-day cooling
    9.0 (EER2)
    Below the middle
    45.4score / 100Heating 60 · Cooling 31

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.

Open the advanced view