Gree vs Rheem: heat pump ratings compared
Against heat pumps of the same size and type, a typical Gree model beats 54% and a typical Rheem model 50%. Gree rates slightly higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Gree
54%
of similar heat pumps beaten by its typical model
About average729 models listed
Rheem
50%
of similar heat pumps beaten by its typical model
About average346 models listed
- Efficiency on a 5°F dayCOP at 5°FGree: Beats 44%Rheem: Beats 59%
- Heating power kept at 5°FCapacity at 5°F vs 47°FGree: Beats 57%Rheem: Beats 49%
- Winter-long heating efficiencyHSPF2Gree: Beats 43%Rheem: Beats 44%
- Summer-long cooling efficiencySEER2Gree: Beats 60%Rheem: Beats 42%
- Hot-day cooling efficiencyEER2Gree: Beats 59%Rheem: Beats 41%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- Gree
- 81%
- Rheem
- 36%
Xcel CC
- Gree
- 80%
- Rheem
- 34%
CEE Advanced
- Gree
- 6%
- Rheem
- 2%
ENERGY STAR CC
- Gree
- 65%
- Rheem
- 33%
All-around best, ducted up to 1.5 tons
Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
Gree
- 1TWH09AUC25R32A1DOwith ducted air handler TM09R32SFDIGree (sold as Tosot)1 ton · 9,100 Btu/h · DuctedCold-climate pick, score 70.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 90% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.15 (COP at 5°F)
- Great
- Winter efficiency
- 9.2 (HSPF2)
- Good
- Cooling efficiency
- 22.0 (SEER2)
- Top 10%
- Hot-day cooling
- 14.2 (EER2)
- Top 10%
- 2GWH09AUCXD-D6DNA1C/Owith ducted air handler GFH(09)DA-D6DN***/IGreeAlso sold as Tosot TAVCI7H4R09, Kinghome KW09XQ25SDO, Tosot TW09HP32A2DOC, Tosot TW09HP32A2DO and 2 more; also listed as ENV09HP230V1R32AO, VIR09HP230V1R32AO, GWH09AGCXD-D6DNA4D/O, GS09HP230V1PUO and 1 more1 ton · 9,100 Btu/h · DuctedCold-climate pick, score 70.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 90% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.14 (COP at 5°F)
- Great
- Winter efficiency
- 9.2 (HSPF2)
- Good
- Cooling efficiency
- 22.0 (SEER2)
- Top 10%
- Hot-day cooling
- 14.2 (EER2)
- Top 10%
- 3MHPC-H-009BSBwith ducted air handler MDUC-H-009BBBGree (sold as Ac Pro)1 ton · 9,000 Btu/h · DuctedCold-climate pick, score 81.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 83% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.32 (COP at 5°F)
- Great
- Winter efficiency
- 11.5 (HSPF2)
- Top 10%
- Cooling efficiency
- 19.7 (SEER2)
- Great
- Hot-day cooling
- 13.0 (EER2)
- Great
Rheem
- 1ML06HP230NEXH-Owith ducted air handler ML06HP230LSDUC-IRheem (sold as Mainline)0.5 tons · 6,500 Btu/h · DuctedCold-climate pick, score 93.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 98% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.41 (COP at 5°F)
- Top 10%
- Winter efficiency
- 13.8 (HSPF2)
- Top 10%
- Cooling efficiency
- 21.4 (SEER2)
- Top 10%
- Hot-day cooling
- 14.4 (EER2)
- Top 10%
- 2ML09HP230NEXH-Owith ducted air handler ML09HP230LSDUC-IRheem (sold as Mainline)1 ton · 9,000 Btu/h · DuctedCold-climate pick, score 80.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 112% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.89 (COP at 5°F)
- Below the middle
- Winter efficiency
- 12.5 (HSPF2)
- Top 10%
- Cooling efficiency
- 21.4 (SEER2)
- Top 10%
- Hot-day cooling
- 13.4 (EER2)
- Top 10%
- 3ML09HP230NEX-Owith ducted air handler ML09HP230HSDUC-IRheem (sold as Mainline)1 ton · 9,000 Btu/h · DuctedCold-climate pick, score 81.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 83% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.32 (COP at 5°F)
- Great
- Winter efficiency
- 11.5 (HSPF2)
- Top 10%
- Cooling efficiency
- 19.7 (SEER2)
- Great
- Hot-day cooling
- 13.0 (EER2)
- Great
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view