HAIER vs TGM: heat pump ratings compared
Against heat pumps of the same size and type, a typical HAIER model beats 51% and a typical TGM model 46%. HAIER rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
HAIER
51%
of similar heat pumps beaten by its typical model
About average38 models listed
TGM
46%
of similar heat pumps beaten by its typical model
About average77 models listed
- Efficiency on a 5°F dayCOP at 5°FHAIER: Beats 32%TGM: Beats 48%
- Heating power kept at 5°FCapacity at 5°F vs 47°FHAIER: Beats 62%TGM: Beats 43%
- Winter-long heating efficiencyHSPF2HAIER: Beats 68%TGM: Beats 41%
- Summer-long cooling efficiencySEER2HAIER: Beats 53%TGM: Beats 45%
- Hot-day cooling efficiencyEER2HAIER: Beats 42%TGM: Beats 43%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- HAIER
- 95%
- TGM
- 58%
Xcel CC
- HAIER
- 82%
- TGM
- 55%
CEE Advanced
- HAIER
- 0%
- TGM
- 1%
ENERGY STAR CC
- HAIER
- 71%
- TGM
- 21%
All-around best, ductless 2.5 to 3 tons
Showing Ductless, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling). What size is my system?
HAIER
- 1AU36VFPTYAHAIER3 tons · 35,600 Btu/h · DuctlessCold-climate pick, score 74.4Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 98% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.8 (HSPF2)
- Top 10%
- Cooling efficiency
- 22.0 (SEER2)
- Good
- Hot-day cooling
- 14.4 (EER2)
- Top 10%
- 21Q3036RT2BE**with ductless indoor unit US30LB2BEHAIER2.5 tons · 30,000 Btu/h · DuctlessCold-climate pick, score 43.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 84% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 10.0 (HSPF2)
- Good
- Cooling efficiency
- 20.0 (SEER2)
- Below the middle
- Hot-day cooling
- 12.0 (EER2)
- Good
- 34Q36RT2BE**HAIER3 tons · 36,000 Btu/h · DuctlessCold-climate pick, score 45.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 94% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 10.0 (HSPF2)
- Good
- Cooling efficiency
- 20.5 (SEER2)
- Below the middle
- Hot-day cooling
- 11.0 (EER2)
- Below the middle
TGM
- 1GMRSHT36AS4TGM3 tons · 36,000 Btu/h · DuctlessCold-climate pick, score 77.8Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Great
- Winter efficiency
- 10.0 (HSPF2)
- Good
- Cooling efficiency
- 21.0 (SEER2)
- Good
- Hot-day cooling
- 12.0 (EER2)
- Good
- 2TMRHT36AS4TGM3 tons · 38,000 Btu/h · DuctlessCold-climate pick, score 54.9Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 74% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.0 (HSPF2)
- Good
- Cooling efficiency
- 23.0 (SEER2)
- Great
- Hot-day cooling
- 11.2 (EER2)
- Below the middle
- 3TMRHT27AS3TGM2.5 tons · 28,000 Btu/h · DuctlessCold-climate pick, score 55.9Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 75% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.0 (HSPF2)
- Good
- Cooling efficiency
- 22.0 (SEER2)
- Good
- Hot-day cooling
- 11.2 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.