Skip to content

iCongo vs Innova SRL: heat pump ratings compared

Against heat pumps of the same size and type, a typical iCongo model beats 42% and a typical Innova SRL model 25%. iCongo rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

iCongo

42%

of similar heat pumps beaten by its typical model

Below average

47 models listed

Innova SRL

25%

of similar heat pumps beaten by its typical model

Well below average

49 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FiCongo: Beats 37%Innova SRL: Beats 13%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FiCongo: Beats 52%Innova SRL: Beats 46%
  • Winter-long heating efficiencyHSPF2iCongo: Beats 48%Innova SRL: Beats 29%
  • Summer-long cooling efficiencySEER2iCongo: Beats 49%Innova SRL: Beats 13%
  • Hot-day cooling efficiencyEER2iCongo: Beats 29%Innova SRL: Beats 27%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    iCongo
    32%
    Innova SRL
    0%
  • Xcel CC

    iCongo
    34%
    Innova SRL
    0%
  • CEE Advanced

    iCongo
    0%
    Innova SRL
    0%
  • ENERGY STAR CC

    iCongo
    0%
    Innova SRL
    43%

All-around best, ducted up to 1.5 tons

iCongo

  1. 1ZOC-18HIN4-M-SE18with ducted air handler ZVMXFA-18HI1N4-C-M-SE18iCongo1.5 tons · 18,000 Btu/h · DuctedCold-climate pick, score 46.3Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    63% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.6 (HSPF2)
    Below the middle
    Cooling efficiency
    18.4 (SEER2)
    Good
    Hot-day cooling
    11.5 (EER2)
    Below the middle
    40.1score / 100Heating 28 · Cooling 52
  2. 2ZOT4P-18HN4-M-SE14.3with ducted air handler ZVMXFA-18C1N4L-M-SE14.3iCongo1.5 tons · 18,000 Btu/h · DuctedNot a cold-climate pick: keeps 52% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    52% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.40 (COP at 5°F)
    Top 10%
    Winter efficiency
    7.5 (HSPF2)
    Below the middle
    Cooling efficiency
    14.3 (SEER2)
    Below the middle
    Hot-day cooling
    11.7 (EER2)
    Good
    39.3score / 100Heating 38 · Cooling 40
  3. 3ZOT4P-18HIN4-M-SE15with ducted air handler ZVMQFA-18HIN4L-M-SE15iCongo1.5 tons · 18,000 Btu/h · DuctedCold-climate pick, score 46.3Meets Xcel CC
    Heat kept at 5°F
    84% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.4 (HSPF2)
    Below the middle
    Cooling efficiency
    15.2 (SEER2)
    Below the middle
    Hot-day cooling
    10.0 (EER2)
    Below the middle
    34.6score / 100Heating 46 · Cooling 23

Innova SRL

  1. 1C5MO09IC1UCInnova SRL0.5 tons · 6,000 Btu/h · DuctedNot a cold-climate pick: keeps 51% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    52% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.16 (COP at 5°F)
    Great
    Winter efficiency
    12.6 (HSPF2)
    Top 10%
    Cooling efficiency
    15.7 (SEER2)
    Below the middle
    Hot-day cooling
    10.4 (EER2)
    Below the middle
    46.7score / 100Heating 62 · Cooling 31
  2. 2VRVB90W0EUCInnova SRLAlso listed as VRVB90W0TUC1.5 tons · 20,200 Btu/h · DuctedNot a cold-climate pick: keeps 47% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    48% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.01 (COP at 5°F)
    Good
    Winter efficiency
    9.2 (HSPF2)
    Below the middle
    Cooling efficiency
    13.9 (SEER2)
    Below the middle
    Hot-day cooling
    11.7 (EER2)
    Good
    37.5score / 100Heating 40 · Cooling 35
  3. 3VRVL50W0TUCInnova SRLAlso listed as VRVL50W0EUC, VRVL50WOEUC, VRVL50WOTUC0.5 tons · 8,900 Btu/h · DuctedCold-climate pick, score 44.4Meets none of the standards tracked here
    Heat kept at 5°F
    73% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.72 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.9 (HSPF2)
    Good
    Cooling efficiency
    14.4 (SEER2)
    Below the middle
    Hot-day cooling
    11.0 (EER2)
    Below the middle
    35.6score / 100Heating 44 · Cooling 27

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.