Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Innova vs Rheem: heat pump ratings compared
Against heat pumps of the same size and type, a typical Innova model beats 32% and a typical Rheem model 49%. Rheem rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Innova
32%
of similar heat pumps beaten by its typical model
Well below average332 models listed
Rheem
49%
of similar heat pumps beaten by its typical model
About average341 models listed
- Efficiency on a 5°F dayCOP at 5°FInnova: Beats 22%Rheem: Beats 59%
- Heating power kept at 5°FCapacity at 5°F vs 47°FInnova: Beats 50%Rheem: Beats 48%
- Winter-long heating efficiencyHSPF2Innova: Beats 41%Rheem: Beats 43%
- Summer-long cooling efficiencySEER2Innova: Beats 22%Rheem: Beats 42%
- Hot-day cooling efficiencyEER2Innova: Beats 29%Rheem: Beats 40%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- Innova
- 0%
- Rheem
- 36%
Xcel CC
- Innova
- 32%
- Rheem
- 34%
CEE Advanced
- Innova
- 0%
- Rheem
- 2%
ENERGY STAR CC
- Innova
- 49%
- Rheem
- 33%
Top cold-climate picks, ductless up to 1.5 tons
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
Showing Ductless, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
Innova
- 1AWP09R3H1InnovaAlso listed as AWP09N3H1, AWP09R3H2, AWP09N3H2, AWE09R3H2 and 24 more0.5 tons · 6,700 Btu/h · DuctlessKeeps 91% of its heat at 5°FMeets ENERGY STAR CC
- Heat kept at 5°F
- 91% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.75 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 8.6 (HSPF2)
- Below the middle
- 2APP10*3*1InnovaAlso listed as APP10*3*2, APK10*3*2, APP10N4H1, APP10N3H1 and 9 more1 ton · 9,000 Btu/h · DuctlessKeeps 81% of its heat at 5°FMeets ENERGY STAR CC
- Heat kept at 5°F
- 81% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.75 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 8.6 (HSPF2)
- Below the middle
- 3APE10*3*2InnovaAlso listed as APP10R4H1, APP10R3H1, APP10R4H2, APP10R3H2 and 7 more1 ton · 9,000 Btu/h · DuctlessKeeps 74% of its heat at 5°FMeets ENERGY STAR CC
- Heat kept at 5°F
- 74% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.75 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 8.6 (HSPF2)
- Below the middle
Rheem
- 1ML06HP230NEXH-Owith ductless indoor unit ML06HP2301WYCAS-IRheem (sold as Mainline)0.5 tons · 6,500 Btu/h · DuctlessKeeps 109% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 109% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.40 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 12.0 (HSPF2)
- Top 10%
- 2ML09HP230NEX-Owith ductless indoor unit ML09HP230CON-IRheem (sold as Mainline)1 ton · 9,000 Btu/h · DuctlessKeeps 96% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 96% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.27 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 13.9 (HSPF2)
- Top 10%
- 3ML06HP230CALH-Owith ductless indoor unit ML06HP230CALH-IRheem (sold as Mainline)0.5 tons · 6,000 Btu/h · DuctlessKeeps 150% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 150% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 15.6 (HSPF2)
- Top 10%
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view