Kaden vs Kerr: heat pump ratings compared
Against heat pumps of the same size and type, a typical Kaden model beats 61% and a typical Kerr model 66%. Kerr rates slightly higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Kaden
61%
of similar heat pumps beaten by its typical model
Well above average66 models listed
Kerr
66%
of similar heat pumps beaten by its typical model
Well above average38 models listed
- Efficiency on a 5°F dayCOP at 5°FKaden: Beats 58%Kerr: Beats 59%
- Heating power kept at 5°FCapacity at 5°F vs 47°FKaden: Beats 53%Kerr: Beats 77%
- Winter-long heating efficiencyHSPF2Kaden: Beats 64%Kerr: Beats 78%
- Summer-long cooling efficiencySEER2Kaden: Beats 63%Kerr: Beats 64%
- Hot-day cooling efficiencyEER2Kaden: Beats 65%Kerr: Beats 62%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- Kaden
- 68%
- Kerr
- 79%
Xcel CC
- Kaden
- 59%
- Kerr
- 90%
CEE Advanced
- Kaden
- 3%
- Kerr
- 3%
ENERGY STAR CC
- Kaden
- 58%
- Kerr
- 90%
Top cold-climate picks, ducted 2 tons
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
Showing Ducted, 2 tons (21,000–26,999 Btu/h cooling). What size is my system?
Kaden
- 1KOB-HH-PSX24HP-2AAMAwith ducted air handler KIB-PSX24HS-2AAMAKaden2 tons · 24,000 Btu/h · DuctedKeeps 92% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 92% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.18 (COP at 5°F)
- Good
- Seasonal efficiency
- 11.7 (HSPF2)
- Top 10%
- 2KOB-PSX24HP-2AAMAwith ducted air handler KIB-PSX24HS-2AAMAKaden2 tons · 24,000 Btu/h · DuctedKeeps 76% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 76% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.30 (COP at 5°F)
- Great
- Seasonal efficiency
- 11.0 (HSPF2)
- Top 10%
- 3KOB-HH-UUX24HP-2AAMAwith ducted air handler KIB-HH-UUX24AH3-2AAMAKaden2 tons · 24,000 Btu/h · DuctedKeeps 86% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 86% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.14 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.0 (HSPF2)
- Great
Kerr
- 1A-KHP24SA-1with ducted air handler B-KHP24DA-1Kerr2 tons · 24,000 Btu/h · DuctedKeeps 92% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 92% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.18 (COP at 5°F)
- Good
- Seasonal efficiency
- 11.7 (HSPF2)
- Top 10%
- 2A-KXP24SA-1with ducted air handler B-KXP24SA-1Kerr2 tons · 23,000 Btu/h · DuctedKeeps 90% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 90% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.87 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 10.0 (HSPF2)
- Great
- 3A-KXP24TA-1with ducted air handler KXP18/24A1AKerr2 tons · 24,000 Btu/h · DuctedKeeps 84% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 84% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 9.5 (HSPF2)
- Good
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.