Skip to content

KEEN Home vs NG Trade: heat pump ratings compared

Against heat pumps of the same size and type, a typical KEEN Home model beats 67% and a typical NG Trade model 55%. KEEN Home rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

KEEN Home

67%

of similar heat pumps beaten by its typical model

Well above average

35 models listed

NG Trade

55%

of similar heat pumps beaten by its typical model

Above average

36 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FKEEN Home: Beats 55%NG Trade: Beats 63%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FKEEN Home: Beats 74%NG Trade: Beats 39%
  • Winter-long heating efficiencyHSPF2KEEN Home: Beats 77%NG Trade: Beats 52%
  • Summer-long cooling efficiencySEER2KEEN Home: Beats 67%NG Trade: Beats 58%
  • Hot-day cooling efficiencyEER2KEEN Home: Beats 65%NG Trade: Beats 46%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    KEEN Home
    91%
    NG Trade
    75%
  • Xcel CC

    KEEN Home
    94%
    NG Trade
    47%
  • CEE Advanced

    KEEN Home
    6%
    NG Trade
    0%
  • ENERGY STAR CC

    KEEN Home
    94%
    NG Trade
    50%

All-around best, ductless up to 1.5 tons

KEEN Home

  1. 1KEENHYMHP06AAwith ductless indoor unit KEENHYMAH612AKEEN HomeAlso listed as KEENHYMHP09AA, KEENHYMHP12AA0.5 tons · 6,000 Btu/h · DuctlessCold-climate pick, score 88.0Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    150% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    15.6 (HSPF2)
    Top 10%
    Cooling efficiency
    35.0 (SEER2)
    Top 10%
    Hot-day cooling
    17.4 (EER2)
    Top 10%
    93.6score / 100Heating 88 · Cooling 99
  2. 2KEENUMHP06AAwith ductless indoor unit KEENOWAH06AAKEEN Home0.5 tons · 6,500 Btu/h · DuctlessCold-climate pick, score 94.9Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    109% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.40 (COP at 5°F)
    Top 10%
    Winter efficiency
    12.0 (HSPF2)
    Top 10%
    Cooling efficiency
    22.0 (SEER2)
    Good
    Hot-day cooling
    15.0 (EER2)
    Top 10%
    86.1score / 100Heating 95 · Cooling 77
  3. 3KEENSTMHP09AAwith ductless indoor unit KEENSTMAH09AAKEEN Home1 ton · 9,000 Btu/h · DuctlessCold-climate pick, score 66.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    96% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    12.5 (HSPF2)
    Top 10%
    Cooling efficiency
    26.0 (SEER2)
    Top 10%
    Hot-day cooling
    15.0 (EER2)
    Top 10%
    80.3score / 100Heating 66 · Cooling 94

NG Trade

  1. 1OMSTAR091Ewith ductless indoor unit IMSTAR091ENG Trade1 ton · 9,000 Btu/h · DuctlessCold-climate pick, score 86.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    82% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.33 (COP at 5°F)
    Top 10%
    Winter efficiency
    13.0 (HSPF2)
    Top 10%
    Cooling efficiency
    24.6 (SEER2)
    Great
    Hot-day cooling
    14.7 (EER2)
    Top 10%
    87.7score / 100Heating 87 · Cooling 89
  2. 2OMSTAR181Ewith ductless indoor unit IMSTAR181ENG Trade1.5 tons · 18,000 Btu/h · DuctlessCold-climate pick, score 74.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    72% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.35 (COP at 5°F)
    Top 10%
    Winter efficiency
    11.1 (HSPF2)
    Great
    Cooling efficiency
    24.0 (SEER2)
    Great
    Hot-day cooling
    13.5 (EER2)
    Great
    78.0score / 100Heating 74 · Cooling 82
  3. 3OMSTAR121Ewith ductless indoor unit IMSTAR121ENG Trade1 ton · 12,000 Btu/h · DuctlessCold-climate pick, score 74.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    72% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.36 (COP at 5°F)
    Top 10%
    Winter efficiency
    11.5 (HSPF2)
    Top 10%
    Cooling efficiency
    23.1 (SEER2)
    Great
    Hot-day cooling
    12.2 (EER2)
    Good
    69.1score / 100Heating 74 · Cooling 64

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter