Skip to content

Lennox vs Midea: heat pump ratings compared

Against heat pumps of the same size and type, a typical Lennox model beats 48% and a typical Midea model 60%. Midea rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Lennox

48%

of similar heat pumps beaten by its typical model

About average

341 models listed

Midea

60%

of similar heat pumps beaten by its typical model

Above average

555 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FLennox: Beats 46%Midea: Beats 60%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FLennox: Beats 43%Midea: Beats 57%
  • Winter-long heating efficiencyHSPF2Lennox: Beats 44%Midea: Beats 66%
  • Summer-long cooling efficiencySEER2Lennox: Beats 44%Midea: Beats 61%
  • Hot-day cooling efficiencyEER2Lennox: Beats 57%Midea: Beats 55%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Lennox
    43%
    Midea
    75%
  • Xcel CC

    Lennox
    36%
    Midea
    70%
  • CEE Advanced

    Lennox
    3%
    Midea
    3%
  • ENERGY STAR CC

    Lennox
    29%
    Midea
    64%

All-around best, ductless 5 tons and up

Lennox

  1. 1VPD060H6M-5PLennox5 tons · 60,000 Btu/h · DuctlessCold-climate pick, score 84.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    85% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.11 (COP at 5°F)
    Good
    Winter efficiency
    11.0 (HSPF2)
    Top 10%
    Cooling efficiency
    23.0 (SEER2)
    Top 10%
    Hot-day cooling
    13.8 (EER2)
    Top 10%
    91.6score / 100Heating 84 · Cooling 99
  2. 2VPD060S6M-5PLennox5 tons · 60,000 Btu/h · DuctlessCold-climate pick, score 61.0Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    83% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.99 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.2 (HSPF2)
    Great
    Cooling efficiency
    20.0 (SEER2)
    Below the middle
    Hot-day cooling
    12.0 (EER2)
    Great
    64.3score / 100Heating 61 · Cooling 68
  3. 3VPC060H5M-3PLennoxAlso listed as VPC060H5M-3P5 tons · 60,000 Btu/h · DuctlessCold-climate pick, score 52.1Meets Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    71% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.87 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.1 (HSPF2)
    Great
    Cooling efficiency
    19.5 (SEER2)
    Below the middle
    Hot-day cooling
    9.5 (EER2)
    Below the middle
    36.8score / 100Heating 52 · Cooling 22

Midea

  1. 1D5CMRAH55FAKMideaAlso sold as MDV M6OE30-60HFN10-M1D, MDV M6OE30-60HFN10-M1; also listed as 37MGRAQ55FA35 tons · 60,000 Btu/h · DuctlessNot a cold-climate pick: keeps 65% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    65% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.20 (COP at 5°F)
    Great
    Winter efficiency
    9.6 (HSPF2)
    Good
    Cooling efficiency
    22.0 (SEER2)
    Great
    Hot-day cooling
    10.0 (EER2)
    Below the middle
    61.8score / 100Heating 64 · Cooling 59
  2. 2MO6EX-H60B-2AMideaAlso sold as MDV M6OE30-60HFN10-M1D-D; also listed as M6OE30-60HFN10-M1P5 tons · 60,000 Btu/h · DuctlessNot a cold-climate pick: keeps 65% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    65% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.20 (COP at 5°F)
    Great
    Winter efficiency
    9.5 (HSPF2)
    Below the middle
    Cooling efficiency
    22.0 (SEER2)
    Great
    Hot-day cooling
    10.0 (EER2)
    Below the middle
    59.0score / 100Heating 59 · Cooling 59
  3. 3MDV-V60WMN10TMideaAlso listed as MDV-V60WMN10T(B)5 tons · 60,000 Btu/h · DuctlessCold-climate pick, score 52.1Meets Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    71% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.87 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.1 (HSPF2)
    Great
    Cooling efficiency
    19.5 (SEER2)
    Below the middle
    Hot-day cooling
    9.5 (EER2)
    Below the middle
    36.8score / 100Heating 52 · Cooling 22

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter