Skip to content

Lithzen vs Live cool: heat pump ratings compared

Against heat pumps of the same size and type, a typical Lithzen model beats 16% and a typical Live cool model 59%. Live cool rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Lithzen

16%

of similar heat pumps beaten by its typical model

Well below average

10 models listed

Live cool

59%

of similar heat pumps beaten by its typical model

Above average

10 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FLithzen: Beats 33%Live cool: Beats 45%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FLithzen: Beats 2%Live cool: Beats 40%
  • Winter-long heating efficiencyHSPF2Lithzen: Beats 3%Live cool: Beats 60%
  • Summer-long cooling efficiencySEER2Lithzen: Beats 12%Live cool: Beats 76%
  • Hot-day cooling efficiencyEER2Lithzen: Beats 19%Live cool: Beats 66%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Lithzen
    20%
    Live cool
    100%
  • Xcel CC

    Lithzen
    0%
    Live cool
    100%
  • CEE Advanced

    Lithzen
    0%
    Live cool
    0%
  • ENERGY STAR CC

    Lithzen
    0%
    Live cool
    90%

All-around best, ductless up to 1.5 tons

Lithzen

  1. 1FP11063US-12WHwith ductless indoor unit FP11063US-22WH/FP11063US-12WHLithzen1.5 tons · 17,100 Btu/h · DuctlessNot a cold-climate pick: keeps 55% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    55% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.22 (COP at 5°F)
    Great
    Winter efficiency
    8.2 (HSPF2)
    Below the middle
    Cooling efficiency
    18.1 (SEER2)
    Below the middle
    Hot-day cooling
    11.6 (EER2)
    Below the middle
    29.8score / 100Heating 32 · Cooling 27
  2. 2FP11116US-12WHwith ductless indoor unit FP11116US-22WH/FP11116US-12WHLithzenAlso listed as FP11303US-12WH1 ton · 12,000 Btu/h · DuctlessNot a cold-climate pick: keeps 48% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    48% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.67 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.2 (HSPF2)
    Below the middle
    Cooling efficiency
    18.1 (SEER2)
    Below the middle
    Hot-day cooling
    10.8 (EER2)
    Below the middle
    11.8score / 100Heating 2 · Cooling 22
  3. 3FP11062US-12WHwith ductless indoor unit FP11062US-22WH/FP11062US-12WHLithzenAlso listed as FP11302US-12WH1 ton · 12,100 Btu/h · DuctlessNot a cold-climate pick: keeps 51% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    52% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.76 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.2 (HSPF2)
    Below the middle
    Cooling efficiency
    18.1 (SEER2)
    Below the middle
    Hot-day cooling
    8.8 (EER2)
    Below the middle
    6.7score / 100Heating 5 · Cooling 8

Live cool

  1. 1KWSM-12IR454BHS24Rwith ductless indoor unit LWSM-12IR454BHS24RLive coolAlso listed as LWSM-12IR454BHS24R1 ton · 12,000 Btu/h · DuctlessCold-climate pick, score 61.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    72% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Great
    Winter efficiency
    10.0 (HSPF2)
    Good
    Cooling efficiency
    24.0 (SEER2)
    Great
    Hot-day cooling
    13.0 (EER2)
    Good
    69.5score / 100Heating 61 · Cooling 78
  2. 2KWSM-12IR454BHS23LRwith ductless indoor unit LWSM-12IR454BHS23LRLive coolAlso listed as LWSM-12IR454BHS23LR1 ton · 12,000 Btu/h · DuctlessCold-climate pick, score 60.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    72% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Great
    Winter efficiency
    10.0 (HSPF2)
    Good
    Cooling efficiency
    23.0 (SEER2)
    Good
    Hot-day cooling
    13.0 (EER2)
    Good
    66.9score / 100Heating 61 · Cooling 73
  3. 3KWSM-09IR454BHS24Rwith ductless indoor unit LWSM-09IR454BHS24RLive coolAlso listed as LWSM-09IR454BHS24R1 ton · 9,000 Btu/h · DuctlessCold-climate pick, score 37.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    71% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.84 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Below the middle
    Cooling efficiency
    23.0 (SEER2)
    Good
    Hot-day cooling
    13.0 (EER2)
    Good
    55.6score / 100Heating 38 · Cooling 73

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter