Skip to content

Midea vs Mitsubishi Electric: heat pump ratings compared

Against heat pumps of the same size and type, a typical Midea model beats 60% and a typical Mitsubishi Electric model 61%. Mitsubishi Electric rates slightly higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Midea

60%

of similar heat pumps beaten by its typical model

Above average

555 models listed

Mitsubishi Electric

61%

of similar heat pumps beaten by its typical model

Well above average

156 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FMidea: Beats 60%Mitsubishi Electric: Beats 56%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FMidea: Beats 57%Mitsubishi Electric: Beats 55%
  • Winter-long heating efficiencyHSPF2Midea: Beats 66%Mitsubishi Electric: Beats 67%
  • Summer-long cooling efficiencySEER2Midea: Beats 61%Mitsubishi Electric: Beats 63%
  • Hot-day cooling efficiencyEER2Midea: Beats 55%Mitsubishi Electric: Beats 61%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Midea
    75%
    Mitsubishi Electric
    81%
  • Xcel CC

    Midea
    70%
    Mitsubishi Electric
    67%
  • CEE Advanced

    Midea
    3%
    Mitsubishi Electric
    10%
  • ENERGY STAR CC

    Midea
    64%
    Mitsubishi Electric
    66%

All-around best, ducted 5 tons and up

Midea

  1. 1MRD-60HWD1N10-M18GMideaAlso listed as MRD-60HWD1N10-M18GB5 tons · 57,000 Btu/h · DuctedCold-climate pick, score 64.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    70% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.85 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.0 (HSPF2)
    Good
    Cooling efficiency
    19.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.2 (EER2)
    Good
    70.5score / 100Heating 64 · Cooling 77
  2. 237MBRAQ58AA3with ducted air handler 45MBDAQ58XH3MideaAlso sold as MDV MOE30-60HFN10-M2; also listed as D5CLRAH58AAK5 tons · 58,000 Btu/h · DuctedNot a cold-climate pick: keeps 66% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    67% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.20 (COP at 5°F)
    Great
    Winter efficiency
    9.8 (HSPF2)
    Top 10%
    Cooling efficiency
    17.0 (SEER2)
    Great
    Hot-day cooling
    10.0 (EER2)
    Below the middle
    66.4score / 100Heating 85 · Cooling 48
  3. 3MO1BU-H60B-2Awith ducted air handler MDHHS-H60B-2AMideaAlso sold as CTMorley MOU-B60L-2; also listed as MOE30-60HFN10-M2P5 tons · 58,000 Btu/h · DuctedNot a cold-climate pick: keeps 66% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    67% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.20 (COP at 5°F)
    Great
    Winter efficiency
    9.7 (HSPF2)
    Top 10%
    Cooling efficiency
    17.0 (SEER2)
    Great
    Hot-day cooling
    10.0 (EER2)
    Below the middle
    65.9score / 100Heating 84 · Cooling 48

Mitsubishi Electric

  1. 1MXZ-SM60NLHZ-**Mitsubishi Electric5 tons · 60,000 Btu/h · DuctedCold-climate pick, score 78.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    91% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.0 (HSPF2)
    Top 10%
    Cooling efficiency
    17.0 (SEER2)
    Great
    Hot-day cooling
    10.2 (EER2)
    Below the middle
    65.7score / 100Heating 79 · Cooling 53
  2. 2MXZ-SM60NL-**Mitsubishi Electric5 tons · 60,000 Btu/h · DuctedCold-climate pick, score 72.4Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    70% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    17.0 (SEER2)
    Great
    Hot-day cooling
    10.2 (EER2)
    Below the middle
    62.5score / 100Heating 72 · Cooling 53
  3. 3MXZ-SM60NLHZ***Mitsubishi ElectricAlso listed as PUMY-HL60NKMU5 tons · 60,000 Btu/h · DuctedCold-climate pick, score 74.0Meets ENERGY STAR CC
    Heat kept at 5°F
    91% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.0 (HSPF2)
    Top 10%
    Cooling efficiency
    16.4 (SEER2)
    Good
    Hot-day cooling
    9.4 (EER2)
    Below the middle
    55.9score / 100Heating 74 · Cooling 38

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter