Skip to content

Mitsutomo vs TUTTOKOOL: heat pump ratings compared

Against heat pumps of the same size and type, a typical Mitsutomo model beats 59% and a typical TUTTOKOOL model 27%. Mitsutomo rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Mitsutomo

59%

of similar heat pumps beaten by its typical model

Above average

57 models listed

TUTTOKOOL

27%

of similar heat pumps beaten by its typical model

Well below average

22 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FMitsutomo: Beats 61%TUTTOKOOL: Beats 46%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FMitsutomo: Beats 59%TUTTOKOOL: Beats 13%
  • Winter-long heating efficiencyHSPF2Mitsutomo: Beats 70%TUTTOKOOL: Beats 17%
  • Summer-long cooling efficiencySEER2Mitsutomo: Beats 57%TUTTOKOOL: Beats 21%
  • Hot-day cooling efficiencyEER2Mitsutomo: Beats 52%TUTTOKOOL: Beats 40%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Mitsutomo
    83%
    TUTTOKOOL
    0%
  • Xcel CC

    Mitsutomo
    75%
    TUTTOKOOL
    0%
  • CEE Advanced

    Mitsutomo
    4%
    TUTTOKOOL
    0%
  • ENERGY STAR CC

    Mitsutomo
    77%
    TUTTOKOOL
    0%

All-around best, ducted 3.5 to 4.5 tons

Mitsutomo

  1. 1RO-MS48-LA-QMitsutomo4 tons · 45,000 Btu/h · DuctedCold-climate pick, score 78.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    81% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    10.6 (HSPF2)
    Top 10%
    Cooling efficiency
    20.4 (SEER2)
    Top 10%
    Hot-day cooling
    12.0 (EER2)
    Great
    85.3score / 100Heating 78 · Cooling 93
  2. 2HO-MS48-LA-QMitsutomo4 tons · 47,000 Btu/h · DuctedCold-climate pick, score 82.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    11.0 (HSPF2)
    Top 10%
    Cooling efficiency
    20.4 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Great
    84.3score / 100Heating 83 · Cooling 86
  3. 3HO-MS60-LA-QMitsutomo4.5 tons · 53,000 Btu/h · DuctedCold-climate pick, score 81.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    87% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    10.7 (HSPF2)
    Top 10%
    Cooling efficiency
    20.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Great
    82.5score / 100Heating 81 · Cooling 84

TUTTOKOOL

  1. 1THP5048A1000Awith ducted air handler T4AH4E61C000ATUTTOKOOL3.5 tons · 44,500 Btu/h · DuctedNot a cold-climate pick: keeps 56% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    49% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.32 (COP at 5°F)
    Great
    Winter efficiency
    7.8 (HSPF2)
    Below the middle
    Cooling efficiency
    15.2 (SEER2)
    Below the middle
    Hot-day cooling
    12.0 (EER2)
    Great
    57.4score / 100Heating 50 · Cooling 65
  2. 2THP5042A1000Awith ducted air handler T4AH4E60C000A+TXVTUTTOKOOL3.5 tons · 41,500 Btu/h · DuctedNot a cold-climate pick: keeps 55% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    50% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.30 (COP at 5°F)
    Great
    Winter efficiency
    7.8 (HSPF2)
    Below the middle
    Cooling efficiency
    15.2 (SEER2)
    Below the middle
    Hot-day cooling
    12.0 (EER2)
    Great
    57.3score / 100Heating 50 · Cooling 65
  3. 3THP5060A1000Awith ducted air handler AE*L+DM60A4J+TDRTUTTOKOOL4 tons · 47,000 Btu/h · DuctedNot a cold-climate pick: keeps 56% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    57% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.34 (COP at 5°F)
    Great
    Winter efficiency
    7.5 (HSPF2)
    Below the middle
    Cooling efficiency
    14.3 (SEER2)
    Below the middle
    Hot-day cooling
    11.2 (EER2)
    Good
    45.6score / 100Heating 51 · Cooling 41

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter