Both views use the same certified data. This device remembers your choice.
Proair vs WILLIS: heat pump ratings compared
Against heat pumps of the same size and type, a typical Proair model beats 53% and a typical WILLIS model 63%. WILLIS rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Proair
53%
of similar heat pumps beaten by its typical model
About average30 models listed
WILLIS
63%
of similar heat pumps beaten by its typical model
Well above average29 models listed
- Efficiency on a 5°F dayCOP at 5°FProair: Beats 50%WILLIS: Beats 45%
- Heating power kept at 5°FCapacity at 5°F vs 47°FProair: Beats 56%WILLIS: Beats 72%
- Winter-long heating efficiencyHSPF2Proair: Beats 60%WILLIS: Beats 51%
- Summer-long cooling efficiencySEER2Proair: Beats 56%WILLIS: Beats 69%
- Hot-day cooling efficiencyEER2Proair: Beats 46%WILLIS: Beats 69%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- Proair
- 70%
- WILLIS
- 97%
Xcel CC
- Proair
- 67%
- WILLIS
- 97%
CEE Advanced
- Proair
- 0%
- WILLIS
- 10%
ENERGY STAR CC
- Proair
- 63%
- WILLIS
- 86%
All-around best, ducted up to 1.5 tons
Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
Proair
- 1PMUL-H3P-18HP-MProair1.5 tons · 19,000 Btu/h · DuctedCold-climate pick, score 71.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 90% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 20.0 (SEER2)
- Great
- Hot-day cooling
- 13.0 (EER2)
- Great
- 2PMUL-A3P-18HP-MProair1.5 tons · 18,000 Btu/h · DuctedCold-climate pick, score 73.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 77% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.30 (COP at 5°F)
- Great
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 20.0 (SEER2)
- Great
- Hot-day cooling
- 12.0 (EER2)
- Good
- 3P30-18CENHP-R454with ducted air handler PAC-24B18T-INTProair1.5 tons · 18,000 Btu/h · DuctedCold-climate pick, score 73.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 95% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.06 (COP at 5°F)
- Good
- Winter efficiency
- 9.5 (HSPF2)
- Good
- Cooling efficiency
- 16.1 (SEER2)
- Good
- Hot-day cooling
- 11.7 (EER2)
- Good
WILLIS
- 1PUHW09KR32-Owith ducted air handler WHEDT09KWILLIS1 ton · 9,100 Btu/h · DuctedCold-climate pick, score 70.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 90% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.14 (COP at 5°F)
- Great
- Winter efficiency
- 9.2 (HSPF2)
- Good
- Cooling efficiency
- 22.0 (SEER2)
- Top 10%
- Hot-day cooling
- 14.2 (EER2)
- Top 10%
- 2AUHW18KR32-Owith ducted air handler WHEDT18KWILLIS1.5 tons · 18,000 Btu/h · DuctedCold-climate pick, score 60.6Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 94% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.4 (HSPF2)
- Good
- Cooling efficiency
- 24.5 (SEER2)
- Top 10%
- Hot-day cooling
- 14.0 (EER2)
- Top 10%
- 3AUHW09KR32-Owith ducted air handler WHEDT09KWILLIS1 ton · 9,100 Btu/h · DuctedCold-climate pick, score 56.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 88% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.5 (HSPF2)
- Good
- Cooling efficiency
- 22.3 (SEER2)
- Top 10%
- Hot-day cooling
- 14.3 (EER2)
- Top 10%
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view