Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Proair vs WILLIS: heat pump ratings compared
Against heat pumps of the same size and type, a typical Proair model beats 52% and a typical WILLIS model 63%. WILLIS rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Proair
52%
of similar heat pumps beaten by its typical model
About average30 models listed
WILLIS
63%
of similar heat pumps beaten by its typical model
Well above average29 models listed
- Efficiency on a 5°F dayCOP at 5°FProair: Beats 49%WILLIS: Beats 44%
- Heating power kept at 5°FCapacity at 5°F vs 47°FProair: Beats 55%WILLIS: Beats 71%
- Winter-long heating efficiencyHSPF2Proair: Beats 59%WILLIS: Beats 50%
- Summer-long cooling efficiencySEER2Proair: Beats 55%WILLIS: Beats 69%
- Hot-day cooling efficiencyEER2Proair: Beats 44%WILLIS: Beats 72%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- Proair
- 70%
- WILLIS
- 97%
Xcel CC
- Proair
- 67%
- WILLIS
- 97%
CEE Advanced
- Proair
- 0%
- WILLIS
- 10%
ENERGY STAR CC
- Proair
- 0%
- WILLIS
- 86%
Top cold-climate picks, ducted up to 1.5 tons
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
Proair
- 1P30-18CENHP-R454with ducted air handler PAC-24B18T-INTProair1.5 tons · 18,000 Btu/h · DuctedKeeps 95% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 95% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.06 (COP at 5°F)
- Good
- Seasonal efficiency
- 9.5 (HSPF2)
- Good
- 2PMUL-A3P-18HP-MProair1.5 tons · 18,000 Btu/h · DuctedKeeps 77% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 77% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.30 (COP at 5°F)
- Great
- Seasonal efficiency
- 10.0 (HSPF2)
- Great
- 3PMUL-H3P-18HP-MProair1.5 tons · 19,000 Btu/h · DuctedKeeps 90% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 90% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.0 (HSPF2)
- Great
WILLIS
- 1PUHW09KR32-Owith ducted air handler WHEDT09KWILLIS1 ton · 9,100 Btu/h · DuctedKeeps 90% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 90% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.14 (COP at 5°F)
- Great
- Seasonal efficiency
- 9.2 (HSPF2)
- Good
- 2AUHW18KR32-Owith ducted air handler WHEDT18KWILLIS1.5 tons · 18,000 Btu/h · DuctedKeeps 94% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 94% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 9.4 (HSPF2)
- Good
- 3AUHW09KR32-Owith ducted air handler WHEDT09KWILLIS1 ton · 9,100 Btu/h · DuctedKeeps 88% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 88% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 9.5 (HSPF2)
- Good
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view