Both views use the same certified data. This device remembers your choice.
QUIK COMFORT vs TEMP SHIFT: heat pump ratings compared
Against heat pumps of the same size and type, a typical QUIK COMFORT model beats 33% and a typical TEMP SHIFT model 67%. TEMP SHIFT rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
QUIK COMFORT
33%
of similar heat pumps beaten by its typical model
Well below average19 models listed
TEMP SHIFT
67%
of similar heat pumps beaten by its typical model
Well above average19 models listed
- Efficiency on a 5°F dayCOP at 5°FQUIK COMFORT: Beats 32%TEMP SHIFT: Beats 52%
- Heating power kept at 5°FCapacity at 5°F vs 47°FQUIK COMFORT: Beats 31%TEMP SHIFT: Beats 80%
- Winter-long heating efficiencyHSPF2QUIK COMFORT: Beats 42%TEMP SHIFT: Beats 80%
- Summer-long cooling efficiencySEER2QUIK COMFORT: Beats 30%TEMP SHIFT: Beats 61%
- Hot-day cooling efficiencyEER2QUIK COMFORT: Beats 37%TEMP SHIFT: Beats 64%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- QUIK COMFORT
- 37%
- TEMP SHIFT
- 95%
Xcel CC
- QUIK COMFORT
- 32%
- TEMP SHIFT
- 90%
CEE Advanced
- QUIK COMFORT
- 0%
- TEMP SHIFT
- 5%
ENERGY STAR CC
- QUIK COMFORT
- 0%
- TEMP SHIFT
- 0%
All-around best, ductless 3.5 to 4.5 tons
Showing Ductless, 3.5 to 4.5 tons (39,000 to 56,999 Btu/h cooling). What size is my system?
QUIK COMFORT
No ductless, 3.5 to 4.5 tons model from QUIK COMFORT.
TEMP SHIFT
- 1TSMZHH556Z2R5TEMP SHIFT4.5 tons · 51,000 Btu/h · DuctlessCold-climate pick, score 70.3Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 87% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Below the middle
- Winter efficiency
- 10.6 (HSPF2)
- Good
- Cooling efficiency
- 21.4 (SEER2)
- Good
- Hot-day cooling
- 12.0 (EER2)
- Good
- 2TSMZHH486Z2R5TEMP SHIFT4 tons · 45,000 Btu/h · DuctlessCold-climate pick, score 69.1Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 98% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Below the middle
- Winter efficiency
- 10.2 (HSPF2)
- Good
- Cooling efficiency
- 21.2 (SEER2)
- Good
- Hot-day cooling
- 12.0 (EER2)
- Good
- 3TSSZHH482R5with ductless indoor unit TSCS482R5TEMP SHIFT4 tons · 48,000 Btu/h · DuctlessCold-climate pick, score 60.4Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 90% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.96 (COP at 5°F)
- Below the middle
- Winter efficiency
- 11.0 (HSPF2)
- Top 10%
- Cooling efficiency
- 18.0 (SEER2)
- Below the middle
- Hot-day cooling
- 10.0 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view