Skip to content

Rheem vs Trane: heat pump ratings compared

Against heat pumps of the same size and type, a typical Rheem model beats 49% and a typical Trane model 50%. Trane rates slightly higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Rheem

49%

of similar heat pumps beaten by its typical model

About average

341 models listed

Trane

50%

of similar heat pumps beaten by its typical model

About average

363 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FRheem: Beats 59%Trane: Beats 68%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FRheem: Beats 48%Trane: Beats 43%
  • Winter-long heating efficiencyHSPF2Rheem: Beats 43%Trane: Beats 36%
  • Summer-long cooling efficiencySEER2Rheem: Beats 42%Trane: Beats 40%
  • Hot-day cooling efficiencyEER2Rheem: Beats 40%Trane: Beats 66%

Average (50%)Dashed outline: the other brand, for comparison

Want ranks, distributions per size class and cold-weather curves? Switch to Advanced

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Rheem
    36%
    Trane
    39%
  • Xcel CC

    Rheem
    34%
    Trane
    26%
  • CEE Advanced

    Rheem
    2%
    Trane
    3%
  • ENERGY STAR CC

    Rheem
    33%
    Trane
    18%

All-around best, ducted up to 1.5 tons

Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.

Rheem

  1. 1ML06HP230NEXH-Owith ducted air handler ML06HP230LSDUC-IRheem (sold as Mainline)0.5 tons · 6,500 Btu/h · DuctedCold-climate pick, score 93.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    98% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.41 (COP at 5°F)
    Top 10%
    Winter efficiency
    13.8 (HSPF2)
    Top 10%
    Cooling efficiency
    21.4 (SEER2)
    Top 10%
    Hot-day cooling
    14.4 (EER2)
    Top 10%
    95.0score / 100Heating 94 · Cooling 97
  2. 2ML09HP230NEXH-Owith ducted air handler ML09HP230LSDUC-IRheem (sold as Mainline)1 ton · 9,000 Btu/h · DuctedCold-climate pick, score 80.0Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    112% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.89 (COP at 5°F)
    Below the middle
    Winter efficiency
    12.5 (HSPF2)
    Top 10%
    Cooling efficiency
    21.4 (SEER2)
    Top 10%
    Hot-day cooling
    13.4 (EER2)
    Top 10%
    86.7score / 100Heating 80 · Cooling 94
  3. 3ML09HP230NEX-Owith ducted air handler ML09HP230HSDUC-IRheem (sold as Mainline)1 ton · 9,000 Btu/h · DuctedCold-climate pick, score 81.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    83% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.32 (COP at 5°F)
    Great
    Winter efficiency
    11.5 (HSPF2)
    Top 10%
    Cooling efficiency
    19.7 (SEER2)
    Great
    Hot-day cooling
    13.0 (EER2)
    Great
    80.8score / 100Heating 81 · Cooling 80

Trane

  1. 15TWV0X24A1with indoor coil D(A,C,E)36C3J+TDR and furnace *UHMB060CCV3+LRPTrane1.5 tons · 20,000 Btu/h · DuctedCold-climate pick, score 92.5Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    120% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.95 (COP at 5°F)
    Top 10%
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    22.2 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Good
    84.4score / 100Heating 92 · Cooling 77
  2. 25TWX5024A1with indoor coil DH36T4J and furnace L9X1A050U3VSATrane1.5 tons · 20,800 Btu/h · DuctedNot a cold-climate pick: keeps 65% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    69% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.51 (COP at 5°F)
    Top 10%
    Winter efficiency
    7.8 (HSPF2)
    Below the middle
    Cooling efficiency
    16.5 (SEER2)
    Good
    Hot-day cooling
    12.0 (EER2)
    Good
    53.6score / 100Heating 46 · Cooling 61
  3. 35TWX5018A1with indoor coil DH36T4J and furnace *UHMB080CCV3Trane1.5 tons · 18,000 Btu/h · DuctedNot a cold-climate pick: keeps 61% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    62% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.64 (COP at 5°F)
    Top 10%
    Winter efficiency
    8.1 (HSPF2)
    Below the middle
    Cooling efficiency
    16.5 (SEER2)
    Good
    Hot-day cooling
    12.0 (EER2)
    Good
    53.5score / 100Heating 46 · Cooling 61

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.

Open the advanced view