Both views use the same certified data. This device remembers your choice.
Rheem vs Trane: heat pump ratings compared
Against heat pumps of the same size and type, a typical Rheem model beats 50% and a typical Trane model 50%. They are level.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Rheem
50%
of similar heat pumps beaten by its typical model
About average346 models listed
Trane
50%
of similar heat pumps beaten by its typical model
About average370 models listed
- Efficiency on a 5°F dayCOP at 5°FRheem: Beats 59%Trane: Beats 69%
- Heating power kept at 5°FCapacity at 5°F vs 47°FRheem: Beats 49%Trane: Beats 43%
- Winter-long heating efficiencyHSPF2Rheem: Beats 44%Trane: Beats 35%
- Summer-long cooling efficiencySEER2Rheem: Beats 42%Trane: Beats 40%
- Hot-day cooling efficiencyEER2Rheem: Beats 41%Trane: Beats 67%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- Rheem
- 36%
- Trane
- 39%
Xcel CC
- Rheem
- 34%
- Trane
- 25%
CEE Advanced
- Rheem
- 2%
- Trane
- 2%
ENERGY STAR CC
- Rheem
- 33%
- Trane
- 17%
Top cold-climate picks, ducted 2.5 to 3 tons
Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling). What size is my system?
Rheem
- 1RD18AY36AJVCwith ducted air handler L(E,G)M36FJRheem2.5 tons · 30,800 Btu/h · DuctedKeeps 109% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 109% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.86 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 10.0 (HSPF2)
- Great
- 2ML36HP230LCMH-Owith ducted air handler ML36HP230HSDUC-IRheem (sold as Mainline)3 tons · 36,000 Btu/h · DuctedKeeps 90% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 90% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Great
- Seasonal efficiency
- 11.1 (HSPF2)
- Top 10%
- 3ML36HP230MULH-ORheem (sold as Mainline)Also listed as ML36HP230MULH-O3 tons · 36,000 Btu/h · DuctedKeeps 106% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 106% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.4 (HSPF2)
- Top 10%
Trane
- 15TCV0X36A1with ducted air handler 5TAMXD06AV41TraneAlso sold as American Standard 5A5V0X36A12.5 tons · 29,000 Btu/h · DuctedKeeps 110% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 110% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.31 (COP at 5°F)
- Great
- Seasonal efficiency
- 10.5 (HSPF2)
- Top 10%
- 25TWV8X36A1with indoor coil D(A,C,E)36C3J+TDR and furnace S8V2C080M5PCBTrane2.5 tons · 29,800 Btu/h · DuctedKeeps 115% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 115% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.85 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 8.5 (HSPF2)
- Good
- 35TCV0X48A1with ducted air handler 5TAMXD05AV41TraneAlso sold as American Standard 5A5V0X48A13 tons · 35,800 Btu/h · DuctedKeeps 104% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 104% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.02 (COP at 5°F)
- Good
- Seasonal efficiency
- 9.7 (HSPF2)
- Great
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view