Skip to content

RUSSELL vs THERMAL ZONE: heat pump ratings compared

Against heat pumps of the same size and type, a typical RUSSELL model beats 33% and a typical THERMAL ZONE model 30%. RUSSELL rates slightly higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

RUSSELL

33%

of similar heat pumps beaten by its typical model

Well below average

111 models listed

THERMAL ZONE

30%

of similar heat pumps beaten by its typical model

Well below average

101 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FRUSSELL: Beats 37%THERMAL ZONE: Beats 40%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FRUSSELL: Beats 21%THERMAL ZONE: Beats 26%
  • Winter-long heating efficiencyHSPF2RUSSELL: Beats 24%THERMAL ZONE: Beats 23%
  • Summer-long cooling efficiencySEER2RUSSELL: Beats 28%THERMAL ZONE: Beats 24%
  • Hot-day cooling efficiencyEER2RUSSELL: Beats 36%THERMAL ZONE: Beats 31%

Average (50%)Dashed outline: the other brand, for comparison

Want ranks, distributions per size class and cold-weather curves? Switch to Advanced

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    RUSSELL
    11%
    THERMAL ZONE
    8%
  • Xcel CC

    RUSSELL
    7%
    THERMAL ZONE
    8%
  • CEE Advanced

    RUSSELL
    0%
    THERMAL ZONE
    0%
  • ENERGY STAR CC

    RUSSELL
    12%
    THERMAL ZONE
    8%

Top cold-climate picks, ducted 3.5–4.5 tons

Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.

RUSSELL

  1. 1SP19AY48AJVCwith indoor coil TCFY4821SEAAM and furnace S802V0754A17DZRUSSELL4 tons · 45,500 Btu/h · DuctedKeeps 92% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    92% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Seasonal efficiency
    10.0 (HSPF2)
    Great
    80.9score / 100
  2. 2RD18AY48AJVCwith ducted air handler SH2VY4821STACNRUSSELL3.5 tons · 41,500 Btu/h · DuctedKeeps 92% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    92% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Seasonal efficiency
    10.0 (HSPF2)
    Great
    80.1score / 100
  3. 3SP19AY60AJVCwith indoor coil TCFY6021SEAAM and furnace S962V0855A21M4RUSSELL4.5 tons · 53,500 Btu/h · DuctedKeeps 92% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    92% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Seasonal efficiency
    10.0 (HSPF2)
    Great
    75.1score / 100

THERMAL ZONE

  1. 1TZID48H520ZCSwith indoor coil TZID60H520ZACD and furnace MGV96U120D5CTHERMAL ZONE4 tons · 45,000 Btu/h · DuctedKeeps 89% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    89% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Below the middle
    Seasonal efficiency
    9.1 (HSPF2)
    Great
    65.9score / 100
  2. 2TZID60H520ZCwith ducted air handler TZID60H520ZATHERMAL ZONE4.5 tons · 55,500 Btu/h · DuctedKeeps 75% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    75% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Seasonal efficiency
    8.6 (HSPF2)
    Good
    64.7score / 100
  3. 3TZID60H520ZCSwith indoor coil TZID60H520ZACD and furnace MGV96U120D5CTHERMAL ZONE4 tons · 50,000 Btu/h · DuctedKeeps 82% of its heat at 5°FMeets ENERGY STAR CC
    Heat kept at 5°F
    82% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Below the middle
    Seasonal efficiency
    8.8 (HSPF2)
    Good
    60.6score / 100

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.

Open the advanced view