Skip to content

Stelpro vs UTL: heat pump ratings compared

Against heat pumps of the same size and type, a typical Stelpro model beats 67% and a typical UTL model 65%. Stelpro rates slightly higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Stelpro

67%

of similar heat pumps beaten by its typical model

Well above average

32 models listed

UTL

65%

of similar heat pumps beaten by its typical model

Well above average

31 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FStelpro: Beats 52%UTL: Beats 81%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FStelpro: Beats 77%UTL: Beats 58%
  • Winter-long heating efficiencyHSPF2Stelpro: Beats 79%UTL: Beats 75%
  • Summer-long cooling efficiencySEER2Stelpro: Beats 68%UTL: Beats 70%
  • Hot-day cooling efficiencyEER2Stelpro: Beats 63%UTL: Beats 46%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Stelpro
    88%
    UTL
    87%
  • Xcel CC

    Stelpro
    94%
    UTL
    84%
  • CEE Advanced

    Stelpro
    0%
    UTL
    10%
  • ENERGY STAR CC

    Stelpro
    78%
    UTL
    97%

All-around best, ducted 3.5 to 4.5 tons

Stelpro

  1. 1SMZ5B1-H48A-OStelproAlso listed as SMZ5B1V-H48A-O4 tons · 47,000 Btu/h · DuctedCold-climate pick, score 82.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    11.0 (HSPF2)
    Top 10%
    Cooling efficiency
    20.4 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Great
    84.3score / 100Heating 83 · Cooling 86
  2. 2SMZ5B1-H55A-OStelproAlso listed as SMZ5B1V-H55A-O4.5 tons · 53,000 Btu/h · DuctedCold-climate pick, score 81.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    87% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    10.7 (HSPF2)
    Top 10%
    Cooling efficiency
    20.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Great
    82.5score / 100Heating 81 · Cooling 84
  3. 3SDB1-H48A-Owith ducted air handler SAHB1-H48A-IStelpro4 tons · 48,000 Btu/h · DuctedCold-climate pick, score 68.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    92% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    16.5 (SEER2)
    Good
    Hot-day cooling
    10.5 (EER2)
    Below the middle
    57.2score / 100Heating 69 · Cooling 46

UTL

  1. 1UCHA-48HDCTwith ducted air handler UCHA-48HDCUTLAlso listed as UCHA-48HDCT, UCHA-48HDCTN24 tons · 48,000 Btu/h · DuctedCold-climate pick, score 73.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    73% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.20 (COP at 5°F)
    Great
    Winter efficiency
    9.8 (HSPF2)
    Great
    Cooling efficiency
    18.5 (SEER2)
    Great
    Hot-day cooling
    11.0 (EER2)
    Below the middle
    68.7score / 100Heating 74 · Cooling 64
  2. 2UCHA-48HDCSN4with ducted air handler UCHA-48HDCN4UTLAlso listed as UCHA-48HDCSN24 tons · 48,000 Btu/h · DuctedCold-climate pick, score 76.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    75% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.25 (COP at 5°F)
    Great
    Winter efficiency
    9.8 (HSPF2)
    Great
    Cooling efficiency
    17.5 (SEER2)
    Good
    Hot-day cooling
    11.0 (EER2)
    Below the middle
    67.9score / 100Heating 77 · Cooling 59
  3. 3UCHA-48HDCTRN2with ducted air handler UCHA-48HDCALN2UTL4 tons · 48,000 Btu/h · DuctedCold-climate pick, score 79.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    79% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.20 (COP at 5°F)
    Great
    Winter efficiency
    10.5 (HSPF2)
    Top 10%
    Cooling efficiency
    16.5 (SEER2)
    Good
    Hot-day cooling
    10.7 (EER2)
    Below the middle
    65.1score / 100Heating 80 · Cooling 50

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter