Skip to content

Viessmann vs YITAHOME: heat pump ratings compared

Against heat pumps of the same size and type, a typical Viessmann model beats 60% and a typical YITAHOME model 35%. Viessmann rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Viessmann

60%

of similar heat pumps beaten by its typical model

Well above average

43 models listed

YITAHOME

35%

of similar heat pumps beaten by its typical model

Well below average

43 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FViessmann: Beats 53%YITAHOME: Beats 71%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FViessmann: Beats 73%YITAHOME: Beats 14%
  • Winter-long heating efficiencyHSPF2Viessmann: Beats 74%YITAHOME: Beats 22%
  • Summer-long cooling efficiencySEER2Viessmann: Beats 59%YITAHOME: Beats 39%
  • Hot-day cooling efficiencyEER2Viessmann: Beats 50%YITAHOME: Beats 28%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Viessmann
    84%
    YITAHOME
    47%
  • Xcel CC

    Viessmann
    79%
    YITAHOME
    12%
  • CEE Advanced

    Viessmann
    5%
    YITAHOME
    0%
  • ENERGY STAR CC

    Viessmann
    70%
    YITAHOME
    0%

All-around best, ductless up to 1.5 tons

Viessmann

  1. 1D5CSHAH06AAKwith ductless indoor unit D5FSHAH06XAKViessmann0.5 tons · 6,000 Btu/h · DuctlessCold-climate pick, score 97.0Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    110% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.40 (COP at 5°F)
    Top 10%
    Winter efficiency
    14.8 (HSPF2)
    Top 10%
    Cooling efficiency
    25.7 (SEER2)
    Top 10%
    Hot-day cooling
    18.0 (EER2)
    Top 10%
    96.9score / 100Heating 97 · Cooling 97
  2. 2D5CSHAH09AAKwith ductless indoor unit D5FSFAH09XAKViessmann1 ton · 9,000 Btu/h · DuctlessCold-climate pick, score 74.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    126% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.84 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.9 (HSPF2)
    Great
    Cooling efficiency
    27.3 (SEER2)
    Top 10%
    Hot-day cooling
    15.2 (EER2)
    Top 10%
    84.4score / 100Heating 73 · Cooling 96
  3. 3D5CMHAH18CAKViessmann1.5 tons · 19,000 Btu/h · DuctlessCold-climate pick, score 75.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    95% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    10.5 (HSPF2)
    Great
    Cooling efficiency
    25.0 (SEER2)
    Great
    Hot-day cooling
    15.0 (EER2)
    Top 10%
    83.7score / 100Heating 76 · Cooling 92

YITAHOME

  1. 1IMHCAC-0032YITAHOME1.5 tons · 17,700 Btu/h · DuctlessCold-climate pick, score 66.2Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    81% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Good
    Cooling efficiency
    22.0 (SEER2)
    Good
    Hot-day cooling
    12.3 (EER2)
    Good
    62.0score / 100Heating 66 · Cooling 58
  2. 2IMHCAC-0024with ductless indoor unit IMHCAC-0023YITAHOMEAlso listed as IMHCAC-0025, IMHCAC-00261 ton · 12,000 Btu/h · DuctlessNot a cold-climate pick: keeps 66% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    67% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.15 (COP at 5°F)
    Great
    Winter efficiency
    10.0 (HSPF2)
    Good
    Cooling efficiency
    21.0 (SEER2)
    Below the middle
    Hot-day cooling
    12.0 (EER2)
    Below the middle
    51.7score / 100Heating 56 · Cooling 47
  3. 3IMHCAC-0010with ductless indoor unit IMHCAC-0009YITAHOMEAlso listed as IMHCAC-00121.5 tons · 17,000 Btu/h · DuctlessNot a cold-climate pick: keeps 65% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    66% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.17 (COP at 5°F)
    Great
    Winter efficiency
    9.0 (HSPF2)
    Below the middle
    Cooling efficiency
    21.0 (SEER2)
    Below the middle
    Hot-day cooling
    12.0 (EER2)
    Below the middle
    45.5score / 100Heating 44 · Cooling 47

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter