Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
New to heat pump ratings? The Simple view explains them in plain words →
ExploreData as of updated · sources
7,039 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 3551MOM18H2BH3AINNOVAIR · MOM Series | Innovair | 1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 95% | 10.4 | 25.0 | 15.0 | 19,000 | CEE 25CEE 26XcelES CC | 3 | 215725516 |
| 3552MOM18H2BH3BINNOVAIR · MOM Series | Innovair | 1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 95% | 10.4 | 25.0 | 15.0 | 19,000 | CEE 25CEE 26XcelES CC | 3 | 215725531 |
| 3553MOM18H2BM3AINNOVAIR · MOM Series | Innovair | 1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.31 | 74% | 9.9 | 22.6 | 13.0 | 14,000 | CEE 25CEE 26XcelES CC | 3 | 215725491 |
| 3554MOM18H2XE2AINNOVAIR · MOM Series | Innovair | 1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.20 | 73% | 9.6 | 22.5 | 13.0 | 13,100 | CEE 25CEE 26XcelES CC | 3 | 218731838 |
| 3555MOM27H2BH4AINNOVAIR · MOM Series | Innovair | 2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 100% | 10.5 | 23.0 | 12.5 | 27,000 | CEE 25CEE 26XcelES CC | 3 | 215725519 |
| 3556MOM27H2BH4BINNOVAIR · MOM Series | Innovair | 2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 100% | 10.5 | 23.0 | 12.5 | 27,000 | CEE 25CEE 26XcelES CC | 3 | 215725534 |
| 3557MOM27H2BM4AINNOVAIR · MOM Series | Innovair | 2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 70% | 9.5 | 25.0 | 13.0 | 19,000 | CEE 25CEE 26XcelES CC | 3 | 215725492 |
| 3558MOM27H2BM4BINNOVAIR · MOM Series | Innovair | 2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 70% | 9.5 | 25.0 | 13.0 | 19,000 | CEE 25CEE 26XcelES CC | 3 | 215725504 |
| 3559MOM27H2XE3AINNOVAIR · MOM Series | Innovair | 2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.80 | 79% | 10.0 | 22.5 | 12.5 | 21,400 | CEE 25CEE 26XcelES CC | 3 | 218731841 |
| 3560MOM36H2BH5AINNOVAIR · MOM Series | Innovair | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 100% | 10.7 | 23.0 | 13.0 | 36,000 | CEE 25CEE 26XcelES CC | 3 | 215725522 |
| 3561MOM36H2BH5BINNOVAIR · MOM Series | Innovair | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 100% | 10.7 | 23.0 | 13.0 | 36,000 | CEE 25CEE 26XcelES CC | 3 | 215725537 |
| 3562MOM36H2BM5AINNOVAIR · MOM Series | Innovair | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 70% | 9.5 | 24.0 | 12.0 | 26,000 | CEE 25CEE 26XcelES CC | 3 | 215725495 |
| 3563MOM36H2BM5BINNOVAIR · MOM Series | Innovair | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 70% | 9.5 | 24.0 | 12.0 | 26,000 | CEE 25CEE 26XcelES CC | 3 | 215725507 |
| 3564MOM36H2XE4AINNOVAIR · MOM Series | Innovair | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 83% | 9.5 | 20.0 | 11.0 | 29,800 | CEE 25CEE 26XcelES CC | 3 | 218731845 |
| 3565MOM48H2BH6AINNOVAIR · MOM Series | Innovair | 4 tons47,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 96% | 11.0 | 23.0 | 12.0 | 47,000 | CEE 25CEE 26XcelES CC | 3 | 215725525 |
| 3566MOM48H2BH6BINNOVAIR · MOM Series | Innovair | 4 tons47,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 96% | 11.0 | 23.0 | 12.0 | 47,000 | CEE 25CEE 26XcelES CC | 3 | 215725540 |
| 3567MOM48H2BM6AINNOVAIR · MOM Series | Innovair | 4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 81% | 10.6 | 20.4 | 12.0 | 38,000 | CEE 25CEE 26XcelES CC | 3 | 215725499 |
| 3568MOM48H2BM6BINNOVAIR · MOM Series | Innovair | 4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 81% | 10.6 | 20.4 | 12.0 | 38,000 | CEE 25CEE 26XcelES CC | 3 | 215725511 |
| 3569MOM48H2XE5AINNOVAIR · MOM Series | Innovair | 4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.90 | 80% | 9.7 | 21.7 | 12.0 | 38,500 | CEE 25CEE 26XcelES CC | 3 | 218731847 |
| 3570MOM60H2BH6AINNOVAIR · MOM Series | Innovair | 4.5 tons53,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 87% | 10.7 | 20.0 | 11.7 | 48,000 | CEE 25CEE 26XcelES CC | 3 | 215835703 |
| 3571MOM60H2BH6BINNOVAIR · MOM Series | Innovair | 4.5 tons53,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 87% | 10.7 | 20.0 | 11.7 | 48,000 | CEE 25CEE 26XcelES CC | 3 | 215835706 |
| 3572MOM60H2BM6AINNOVAIR | Innovair | 5 tons60,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.20 | 65% | 9.5 | 22.0 | 10.0 | 39,000 | CEE 25CEE 26 | 3 | 215835696 |
| 3573MOM60H2BM6BINNOVAIR | Innovair | 5 tons60,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.20 | 65% | 9.5 | 22.0 | 10.0 | 39,000 | CEE 25CEE 26 | 3 | 215835699 |
| 3574MOS06H2BH0AINNOVAIR · MHW Serieswith ductless indoor unit MHW06H2BHRB | Innovair | 0.5 tons6,000 Btu/h · Non-ducted | 2.40 | 110% | 14.8 | 25.5 | 18.0 | 7,700 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 215725442 |
| 3575MOS09H1BE5AINNOVAIRwith ductless indoor unit MHW09H1BERA | Innovair | 1 ton9,000 Btu/h · Non-ducted | 1.83 | 61% | 9.0 | 18.0 | 10.1 | 6,000 | CEE 25 | 1 | 215725428 |