Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

5,144 models

Sorted by manufacturer and model.
Page 32 of 206
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
77637MURAQ24AA3+KSAIC0701230CARRIER · Crossover heat pumpwith ducted air handler FM(C,U)5Z30**ALCarrier2 tons24,800 Btu/h · Ducted2.1482%9.516.010.019,600CEE 25CEE 26XcelES CC1,444218475082
77737MURAQ36AA3CARRIERwith indoor coil D(A,C,E)37A3J+TDR and furnace 58TP*B090V17**16Carrier3 tons34,800 Btu/h · Ducted2.6269%8.514.88.025,400CEE 25CEE 26XcelES CC2,594218331534
77837MURAQ48AA3CARRIERwith ducted air handler L(E,G)M60AJCarrier4 tons45,500 Btu/h · Ducted2.5160%7.814.59.028,400CEE 25CEE 26XcelES CC813218331657
77937MURAQ48AA3+KSAIC0701230CARRIER · Crossover Heat Pumpwith indoor coil CAA**6124AM and furnace 58SP*B090V21**20Carrier4 tons48,000 Btu/h · Ducted2.0078%8.015.08.538,000ES CC718218475884
78037MURAQ60AA3CARRIERwith ducted air handler D(A,C,E)60B3J+TDRCarrier4 tons48,000 Btu/h · Ducted2.4168%7.514.38.232,800ES CC107217894879
78137MVRAQ09AA3CARRIER · D5M Serieswith ductless indoor unit D5MVHAQ09XA3Carrier1 ton9,000 Btu/h · Non-ducted2.1670%9.719.010.97,000CEE 25CEE 26XcelES CC8215323838
78237MVRAQ24AA3CARRIER · D5M Serieswith ductless indoor unit D5MVHAQ24XA3Carrier2 tons24,000 Btu/h · Non-ducted2.0171%8.517.09.017,100XcelES CC8215323841
78337VMB030HDS3-1CARRIER · 37VMB030HDS3-1Carrier2.5 tons30,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.03101%10.120.014.030,400CEE 25CEE 26XcelES CC3216369711
78437VMB036HDS3-1CARRIER · 37VMB036HDS3-1Carrier3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9986%10.120.013.334,200CEE 25CEE 26XcelES CC9216369712
78537VMB048HDS3-1CARRIER · 37VMB048HDS3-1Carrier4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0080%10.120.011.740,000CEE 25CEE 26XcelES CC9216369713
78637VMB060HDS3-1CARRIER · 37VMB060HDS3-1Carrier5 tons60,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8771%10.119.59.542,800XcelES CC9216369714
787B5H0V24*K*AAA*HEIL · QUIETCOMFORT DELUXE 20 VS HPwith ducted air handler FCMA5X24L0B*+WALLCONCarrier2 tons23,400 Btu/h · Ducted2.0470%9.017.510.516,600CEE 25CEE 26XcelES CC2,511218160740
788B5H0V36*K*AAA*HEIL · QUIETCOMFORT DELUXE 20 VS HPwith ducted air handler FCMA5B60L0D*+WALLCONCarrier3 tons35,400 Btu/h · Ducted2.0472%9.519.511.524,400CEE 25CEE 26XcelES CC5,402218162463
789B5H0V48*K*AAA*HEIL · QUIETCOMFORT DELUXE 20 VS HPwith ducted air handler FCMA5B60L0D*+WALLCONCarrier4 tons46,500 Btu/h · Ducted2.2070%9.519.510.533,000CEE 25CEE 26XcelES CC2,478218166149
790B5H0V60*K*AAA*TEMPSTAR · SmartSense 20 VS HPwith indoor coil EVM5X60M21A*+WALLCON and furnace *80CSU0401712BCarrier4.5 tons56,000 Btu/h · Ducted2.1572%8.118.09.543,500CEE 25CEE 26XcelES CC1,249218165756
791B5H3V24*K*AAA*HEIL · QUIETCOMFORT DELUXE 23 VS HPwith indoor coil EVM5X25M17A*+WALLCON and furnace *80CSU0401712BCarrier2 tons23,200 Btu/h · Ducted2.1081%9.522.013.022,200CEE 25CEE 26XcelES CC3,310218407304
792B5H3V36*K*AAA*HEIL · QUIETCOMFORT DELUXE 23 VS HPwith ducted air handler FCMA5B60L0D*+WALLCONCarrier3 tons35,000 Btu/h · Ducted2.1075%9.522.012.525,200CEE 25CEE 26XcelES CC4,125218405880
793B5H3V48*K*AAA*HEIL · QUIETCOMFORT DELUXE 23 VS HPwith ducted air handler FCMA5B48L0C*+WALLCONCarrier4 tons45,500 Btu/h · Ducted2.0074%9.522.012.036,000CEE 25CEE 26XcelES CC1,672218414880
794B5H3V60*K*AAA*HEIL · QUIETCOMFORT DELUXE 23 VS HPwith ducted air handler FCMA5B60L0D*+WALLCONCarrier5 tons58,000 Btu/h · Ducted2.1874%9.020.012.544,500CEE 25CEE 26XcelES CC1,247218405896
795C5H0V24*K*AAA*COMFORTMAKER · SoftSound 20 VS Heat Pumpwith ducted air handler FCMA5X24L0B*+WALLCONCarrier2 tons23,400 Btu/h · Ducted2.0468%9.017.510.516,600CEE 25CEE 26XcelES CC1,256215662826
796C5H0V36*K*AAA*COMFORTMAKER · SoftSound 20 VS Heat Pumpwith ducted air handler FCMA5B60L0D*+WALLCONCarrier3 tons35,400 Btu/h · Ducted2.0472%9.519.511.524,400CEE 25CEE 26XcelES CC2,526215670621
797C5H0V48*K*AAA*COMFORTMAKER · SoftSound 20 VS Heat Pumpwith ducted air handler FCMA5B60L0D*+WALLCONCarrier4 tons46,500 Btu/h · Ducted2.2070%9.519.510.533,000CEE 25CEE 26XcelES CC1,231215675348
798C5H0V60*K*AAA*COMFORTMAKER · SoftSound 20 VS Heat Pumpwith ducted air handler FCMA5B60L0D*+WALLCONCarrier5 tons57,500 Btu/h · Ducted2.1269%9.020.010.040,500CEE 25CEE 26ES CC596215662892
799C5H3V36*K*AAA*COMFORTMAKER · SoftSound 23 VS Heat Pumpwith indoor coil EVD5X60M21A*+WALLCON and furnace *95CSU1002122BCarrier3 tons35,600 Btu/h · Ducted2.1475%9.022.012.528,400CEE 25CEE 26XcelES CC1,827215936669
800C5H3V48*K*AAA*COMFORTMAKER · SoftSound 23 VS Heat Pumpwith indoor coil EA*5X48M21A*+WALLCON and furnace *80CSU1002120ACarrier3.5 tons43,500 Btu/h · Ducted2.0076%9.520.510.536,600CEE 25CEE 26XcelES CC999215933979

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 5,144 models; narrow the filters for the rest.