Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

7,036 models

Sorted by manufacturer and model.
Page 50 of 282
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
1226D5CMTAH48FAKARCOAIRE · D5C SeriesCarrier4 tons48,000 Btu/h · Non-ducted1.8575%9.518.710.036,000CEE 25CEE 26XcelES CC9216765606
1227D5CPRAH06AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FPHAH06XAKCarrier0.5 tons6,000 Btu/h · Non-ducted2.00150%15.633.116.513,500CEE 25CEE 26XcelES CC9215413211
1228D5CPRAH09AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FPHAH09XAKCarrier1 ton9,000 Btu/h · Non-ducted2.00113%14.631.516.013,500CEE 25CEE 26XcelES CC9215413212
1229D5CPRAH12AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FPHAH12XAKCarrier1 ton12,000 Btu/h · Non-ducted2.00113%12.728.013.513,500CEE 25CEE 26XcelES CC10215413213
1230D5CPRAH18AAARCOAIRE · D5F Serieswith ductless indoor unit D5FPHAH18XAKCarrier1.5 tons18,000 Btu/h · Non-ducted2.34113%15.224.514.022,600CEE 25CEE 26CEE AdvXcelDOEES CC10215413214
1231D5CSHAH06AAKARCOAIRE · D5F Serieswith ducted air handler D5FSDAH06XAKCarrier0.5 tons6,500 Btu/h · Ducted and non-ducted2.4198%13.821.514.57,800CEE 25CEE 26CEE AdvXcelDOEES CC27215324104
1232D5CSHAH09AAKARCOAIRE · D5F Serieswith ducted air handler D5FSDAH12XAKCarrier1 ton9,000 Btu/h · Ducted and non-ducted1.89112%12.521.513.511,200CEE 25CEE 26XcelES CC54215324109
1233D5CSHAH12AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FSOAH12XAKCarrier1 ton12,000 Btu/h · Ducted and non-ducted1.9992%10.223.013.011,500CEE 25CEE 26XcelES CC54215324112
1234D5CSHAH18AAKARCOAIRE · D5F Serieswith ducted air handler D5FSAAH18XBKCarrier1.5 tons18,000 Btu/h · Ducted and non-ducted2.2092%10.118.212.018,000CEE 25CEE 26XcelES CC73215318904
1235D5CSHAH24AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FSHAH24XAKCarrier2 tons24,000 Btu/h · Ducted and non-ducted2.3483%13.521.213.024,200CEE 25CEE 26XcelES CC46215324124
1236D5CSHAH33AAKARCOAIRE · D5F Serieswith ducted air handler D5FSAAH36XBKCarrier3 tons33,000 Btu/h · Ducted and non-ducted2.0097%10.016.711.734,000CEE 25CEE 26XcelES CC19215318906
1237D5CSRAH09AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FSHAH09XAKCarrier1 ton9,000 Btu/h · Ducted and non-ducted2.3780%12.526.014.98,000CEE 25CEE 26XcelES CC54215324130
1238D5CSRAH12AAJARCOAIRE · D5F Serieswith ductless indoor unit D5FSHAH12XAJCarrier1 ton12,000 Btu/h · Non-ducted2.3364%9.523.513.07,700CEE 25CEE 2610215324129
1239D5CSRAH12AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FSFAH12XAKCarrier1 ton12,000 Btu/h · Ducted and non-ducted2.5174%11.024.712.78,900CEE 25CEE 26XcelES CC54215324139
1240D5CSRAH18AAKARCOAIRE · D5F Serieswith ducted air handler D5FSDAH18XHKCarrier1.5 tons17,500 Btu/h · Ducted and non-ducted2.4171%11.420.013.314,200CEE 25CEE 26XcelES CC73215324148
1241D5CSRAH24AAKARCOAIREwith ductless indoor unit D5FPHAH18XAKCarrier2 tons24,000 Btu/h · Ducted and non-ducted2.5478%11.723.114.019,600CEE 25CEE 26XcelES CC56215324149
1242D5CSRAH30AAKARCOAIRE · D5F Serieswith ducted air handler D5FSAAH30XBKCarrier2.5 tons30,000 Btu/h · Ducted and non-ducted2.1068%8.817.011.020,400CEE 25CEE 2629215413032
1243D5CUHAH18AAKTEMPSTARwith ducted air handler D(A,C,E)30A3J+TDRCarrier1.5 tons17,700 Btu/h · Ducted2.8680%8.516.011.715,000CEE 25CEE 26CEE AdvXcelDOEES CC1,293217906663
1244D5CUHAH18AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FM(C,U)5Z30**ALCarrier1.5 tons18,400 Btu/h · Ducted2.0483%9.016.011.016,800CEE 25CEE 26XcelES CC1,684218483199
1245D5CUHAH18AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith ducted air handler FM(C,U)5Z30**ALCarrier1.5 tons18,400 Btu/h · Ducted2.0483%9.016.011.016,800CEE 25CEE 26XcelES CC1,809217399865
1246D5CUHAH24AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDRCarrier2 tons23,800 Btu/h · Ducted2.8879%8.516.09.819,500CEE 25CEE 26XcelES CC5,132217906665
1247D5CUHAH24AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FHMA5*30L*BCarrier2 tons24,200 Btu/h · Ducted2.0683%9.016.011.019,000CEE 25CEE 26XcelES CC4,433218486193
1248D5CUHAH24AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith ducted air handler FHMA5*30L*BCarrier2 tons24,200 Btu/h · Ducted2.0683%9.016.011.019,000CEE 25CEE 26XcelES CC4,391217635077
1249D5CUHAH30AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDRCarrier2.5 tons28,000 Btu/h · Ducted2.4880%7.815.29.823,800CEE 25CEE 26XcelES CC1,064217906667
1250D5CUHAH30AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith indoor coil EA*5X43M21A and furnace OLV112A16ACarrier2.5 tons31,200 Btu/h · Ducted2.0089%9.015.510.032,200CEE 25CEE 26XcelES CC4,115218490362

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 7,036 models; narrow the filters for the rest.