- Insights
- Explore
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
New to heat pump ratings? The Simple view explains them in plain words →
ExploreData as of updated · sources
7,036 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1251D5CUHAH30AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith indoor coil EA*5X43M21A and furnace OLV112A16A | Carrier | 2.5 tons31,200 Btu/h · Ducted | 2.00 | 89% | 9.0 | 15.5 | 10.0 | 32,200 | CEE 25CEE 26XcelES CC | 4,261 | 217396826 |
| 1252D5CUHAH36AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDR | Carrier | 3 tons35,000 Btu/h · Ducted | 2.14 | 74% | 8.0 | 15.2 | 10.0 | 27,000 | CEE 25CEE 26XcelES CC | 204 | 217906668 |
| 1253D5CUHAH36AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FMA5X36**AL | Carrier | 3 tons36,200 Btu/h · Ducted | 1.90 | 79% | 9.0 | 16.5 | 10.0 | 31,600 | CEE 25CEE 26XcelES CC | 3,937 | 218495042 |
| 1254D5CUHAH36AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith ducted air handler FMA5X36**AL | Carrier | 3 tons36,200 Btu/h · Ducted | 1.90 | 79% | 9.0 | 16.5 | 10.0 | 31,600 | CEE 25CEE 26XcelES CC | 4,146 | 217486562 |
| 1255D5CUHAH48AAKTEMPSTARwith ducted air handler D(A,C,E)60B3J+TDR | Carrier | 4 tons45,000 Btu/h · Ducted | 2.43 | 75% | 8.0 | 15.2 | 9.8 | 33,800 | CEE 25CEE 26XcelES CC | 224 | 217906669 |
| 1256D5CUHAH60AAKTEMPSTARwith ducted air handler D(A,C,E)60B3J+TDR | Carrier | 4 tons45,000 Btu/h · Ducted | 2.12 | 62% | 7.5 | 15.2 | 9.8 | 35,800 | CEE 25CEE 26XcelES CC | 170 | 217906670 |
| 1257D5CUHAH60AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler F5MA5*60L*D | Carrier | 4.5 tons55,500 Btu/h · Ducted | 1.80 | 90% | 9.0 | 15.0 | 9.5 | 50,500 | CEE 25CEE 26ES CC | 566 | 218477311 |
| 1258D5CUHAH60AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith ducted air handler FEVB0060**+NAVA56001CK | Carrier | 4.5 tons53,500 Btu/h · Ducted | 1.86 | 90% | 9.0 | 14.5 | 9.5 | 51,500 | CEE 25CEE 26XcelES CC | 104 | 217969657 |
| 1259D5CURAH18AAKTEMPSTARwith ducted air handler D(A,C,E)30A3J+TDR | Carrier | 1.5 tons17,700 Btu/h · Ducted | 2.83 | 75% | 7.8 | 16.0 | 10.0 | 13,300 | CEE 25CEE 26Xcel | 2,297 | 217906671 |
| 1260D5CURAH18AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FM(C,U)5Z30**AL | Carrier | 1.5 tons18,200 Btu/h · Ducted | 2.10 | 61% | 9.0 | 17.0 | 10.5 | 11,800 | CEE 25CEE 26 | 2,955 | 218609651 |
| 1261D5CURAH24AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDR | Carrier | 2 tons23,800 Btu/h · Ducted | 2.88 | 79% | 8.5 | 16.0 | 9.8 | 19,500 | CEE 25CEE 26XcelES CC | 2,839 | 217906673 |
| 1262D5CURAH24AAK+KSAIC0701230HEIL · Crossover heat pumpwith ducted air handler FM(C,U)5Z30**AL | Carrier | 2 tons24,800 Btu/h · Ducted | 2.14 | 82% | 9.5 | 16.0 | 10.0 | 19,600 | CEE 25CEE 26XcelES CC | 2,166 | 218498234 |
| 1263D5CURAH30AAKTEMPSTARwith ducted air handler D(A,C,E)30A3J+TDR | Carrier | 2 tons26,600 Btu/h · Ducted | 2.21 | 66% | 7.5 | 15.2 | 9.8 | 18,800 | CEE 25CEE 26Xcel | 2,958 | 217906674 |
| 1264D5CURAH36AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDR | Carrier | 3 tons33,200 Btu/h · Ducted | 2.54 | 72% | 8.1 | 14.5 | 9.0 | 25,400 | CEE 25CEE 26XcelES CC | 2,799 | 217906675 |
| 1265D5CURAH48AAKHEIL · Crossover heat pumpwith ducted air handler FTMA5B60L0D | Carrier | 4 tons47,500 Btu/h · Ducted | 1.86 | 81% | 8.0 | 15.5 | 9.5 | 37,600 | CEE 25CEE 26XcelES CC | 650 | 216772706 |
| 1266D5CVRAH09AAJARCOAIRE · D5F Serieswith ductless indoor unit D5FVHAH09XAJ | Carrier | 1 ton9,000 Btu/h · Non-ducted | 1.83 | 61% | 9.0 | 18.0 | 10.1 | 6,000 | CEE 25 | 18 | 215324153 |
| 1267D5CVRAH09AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FVHAH09XAK | Carrier | 1 ton9,000 Btu/h · Non-ducted | 2.16 | 70% | 9.7 | 19.0 | 10.9 | 7,000 | CEE 25CEE 26XcelES CC | 18 | 215324155 |
| 1268GH5SAN524**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)34J | Carrier | 2 tons21,400 Btu/h · Ducted | 2.70 | 65% | 7.5 | 15.2 | 12.0 | 14,700 | CEE 25CEE 26 | 3,697 | 217229867 |
| 1269GH5SAN531**AA*BRYANT HEATING AND COOLING SYSTEMS · 15 SEER2 HPwith indoor coil CAA**3721AM and furnace 83*CB36040C17 | Carrier | 2.5 tons29,200 Btu/h · Ducted | 2.06 | 46% | 8.0 | 15.5 | 12.0 | 13,900 | CEE 25 | 1,399 | 217680505 |
| 1270GH5SAN536**AA*CARRIERwith ducted air handler C/SEHX-37-**-EP-1C81+CF037SEUB+TXV+TDR | Carrier | 3 tons34,000 Btu/h · Ducted | 2.76 | 53% | 7.8 | 15.2 | 12.2 | 17,200 | CEE 25 | 3,474 | 216064758 |
| 1271GH8TAN524**AA*CARRIER · 2-STAGE 18 SEER HPwith indoor coil CAA**3721AM and furnace 58SU*B040M17**12 | Carrier | 2 tons23,800 Btu/h · Ducted | 2.24 | 45% | 8.5 | 18.0 | 13.0 | 11,100 | CEE 25 | 2,769 | 215647845 |
| 1272GH8TAN536**AA*CARRIER · 2-STAGE 18 SEER HPwith ducted air handler FT5ANBD60L | Carrier | 3 tons36,000 Btu/h · Ducted | 2.48 | 49% | 8.5 | 17.0 | 13.0 | 18,600 | CEE 25CEE 26 | 2,663 | 215628936 |
| 1273GH8TAN548**AA*CARRIER · 2-STAGE 18 SEER HPwith ducted air handler FT5ANBD60L | Carrier | 4 tons48,500 Btu/h · Ducted | 2.32 | 51% | 8.1 | 18.0 | 13.5 | 24,600 | CEE 25CEE 26 | 2,290 | 215560705 |
| 1274GH8TAN560**AA*CARRIER · 2-STAGE 18 SEER HPwith indoor coil CVAMA6124XMA and furnace 58TN*B135C24**22 | Carrier | 4.5 tons56,000 Btu/h · Ducted | 2.34 | 52% | 8.5 | 15.5 | 11.5 | 31,400 | CEE 25CEE 26 | 1,353 | 215626617 |
| 1275H5H0V24*K*AAA*HEILwith indoor coil D(A,C,E)37A3J+TDR and furnace *80CSU0401712B | Carrier | 2 tons23,000 Btu/h · Ducted | 2.76 | 94% | 8.5 | 16.5 | 9.8 | 23,200 | CEE 25CEE 26XcelES CC | 1,284 | 218372590 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 7,036 models; narrow the filters for the rest.