Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

7,036 models

Sorted by manufacturer and model.
Page 53 of 282
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
1301N5H5S24*K*AAA*HEILwith indoor coil D(A,C,E)37A3J+TDR and furnace *96MSN0802120ACarrier2 tons21,800 Btu/h · Ducted2.7672%7.514.811.715,500CEE 25CEE 26Xcel12,665218371357
1302N5H5S36*K*AAA*HEILwith indoor coil D(A,C,E)36B3J+TDR and furnace *80MS(N,L)1102120ACarrier2.5 tons31,000 Btu/h · Ducted2.6569%7.514.811.722,800CEE 2511,024217597897
1303N5H5S36*L*AAA*HEIL · PERFORMANCE 16 SEER2 HPwith ducted air handler FHMA5*48L*CCarrier3 tons36,800 Btu/h · Ducted2.2048%8.016.013.017,400CEE 25952217033623
1304N5H8T24*K*AAA*HEIL · 2-STAGE 18 SEER HPwith indoor coil EA*5X37M21A and furnace *80MSU0401712ACarrier2 tons23,800 Btu/h · Ducted2.2445%8.518.013.011,100CEE 259,321215647855
1305N5H8T36*K*AAA*HEIL · 2-STAGE 18 SEER HPwith ducted air handler FTMA5B60L0DCarrier3 tons36,000 Btu/h · Ducted2.4849%8.517.013.018,600CEE 25CEE 267,347215628950
1306N5H8T48*K*AAA*COMFORTMAKERwith ducted air handler AE*L+CM48A4J+TDRCarrier4 tons45,000 Btu/h · Ducted2.9063%7.517.012.529,200CEE 25CEE 265,488218114575
1307N5H8T60*K*AAA*COMFORTMAKERwith indoor coil C(A,C,D,E)60D2J+TDR and furnace *80CTL0902120BCarrier4 tons48,500 Btu/h · Ducted2.7063%7.815.511.235,200CEE 25CEE 263,851218687517
1308N5H9V24*K*AAA*ARCOAIRE · Performance 19 SEER2 VS HPwith ducted air handler FTMA5B36L0CCarrier2 tons23,400 Btu/h · Ducted2.0287%10.018.514.021,200CEE 25CEE 26XcelES CC7,747217950375
1309N5H9V36*K*AAA*ARCOAIRE · Performance 19 SEER2 VS HPwith ducted air handler F5MA5*36L*BCarrier3 tons33,600 Btu/h · Ducted2.1877%9.015.212.024,800CEE 25CEE 26XcelES CC5,900217928530
1310N5H9V48*K*AAA*ARCOAIRE · Performance 19 SEER2 VS HPwith ducted air handler FTMA5B60L0DCarrier4 tons46,000 Btu/h · Ducted2.3275%10.019.012.536,000CEE 25CEE 26XcelES CC3,955217914939
1311N5H9V60*K*AAA*ARCOAIRE · Performance 19 SEER2 VS HPwith ducted air handler F5MA5*60L*DCarrier4.5 tons56,000 Btu/h · Ducted2.1670%9.016.011.740,000CEE 25CEE 26XcelES CC2,750217933356
1312PH5SAN524**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)29JCarrier2 tons21,000 Btu/h · Ducted2.6465%7.515.211.714,700CEE 25CEE 265,266217006633
1313PH5SAN524**AB*WEATHERMAKER · 15 SEER2 HPwith ducted air handler FMA5X30**ALCarrier2 tons24,000 Btu/h · Ducted2.2649%8.516.513.011,600CEE 25CEE 26450218754045
1314PH5SAN531**AA*BRYANT HEATING AND COOLING SYSTEMS · 15 SEER2 HPwith indoor coil CAA**3721AM and furnace 83*CB36040C17Carrier2.5 tons29,200 Btu/h · Ducted2.0646%8.015.512.013,900CEE 251,399217680506
1315PH5SAN531**AB*WEATHERMAKER · 15 SEER2 HPwith indoor coil CAA**3721AM and furnace PG80MS(A,L)A48070CCarrier2.5 tons29,200 Btu/h · Ducted2.0646%8.015.012.514,100CEE 25326218754147
1316PH5SAN536**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)38JCarrier2.5 tons32,400 Btu/h · Ducted2.6160%7.514.311.721,000CEE 253,457217006636
1317PH5SAN536**AB*WEATHERMAKER · 15 SEER2 HPwith ducted air handler FEVB0048**+NAVA54801CKCarrier3 tons36,400 Btu/h · Ducted2.2248%7.815.512.517,400CEE 25351218754040
1318PH8TAN524**AA*BRYANT HEATING AND COOLING SYSTEMS · 2-STAGE 18 SEER HPwith indoor coil CAA**3721AM and furnace 83*SB36040M17Carrier2 tons23,800 Btu/h · Ducted2.2445%8.518.013.011,100CEE 252,154215647849
1319PH8TAN524**AB*WEATHERMAKER · 2-STAGE 18 SEER HPwith indoor coil CAA**3721AM and furnace PG80MSUA36040BCarrier2 tons23,800 Btu/h · Ducted2.2445%8.518.013.011,100CEE 25362218755458
1320PH8TAN536**AA*BRYANT HEATING AND COOLING SYSTEMS · 2-STAGE 18 SEER HPwith ducted air handler FT5ANBD60LCarrier3 tons36,000 Btu/h · Ducted2.4849%8.517.013.018,600CEE 25CEE 261,576215628944
1321PH8TAN536**AB*WEATHERMAKER · 2-STAGE 18 SEER HPwith ducted air handler PF5TNBD60LCarrier3 tons36,000 Btu/h · Ducted2.4849%8.517.013.018,600CEE 25CEE 26289218755135
1322PH8TAN548**AA*BRYANT HEATING AND COOLING SYSTEMS · 2-STAGE 18 SEER HPwith ducted air handler FT5ANBD60LCarrier4 tons48,500 Btu/h · Ducted2.3251%8.118.013.524,600CEE 25CEE 261,195215560713
1323PH8TAN548**AB*WEATHERMAKER · 2-STAGE 18 SEER HPwith ducted air handler PF5TNBD60LCarrier4 tons48,500 Btu/h · Ducted2.3251%8.118.013.524,600CEE 25CEE 26202218754767
1324PH8TAN560**AA*BRYANT HEATING AND COOLING SYSTEMS · 2-STAGE 18 SEER HPwith indoor coil CVAMA6124XMA and furnace 88*TB66135C24Carrier4.5 tons56,000 Btu/h · Ducted2.3452%8.515.511.531,400CEE 25CEE 26756215626620
1325PH8TAN560**AB*WEATHERMAKER · 2-STAGE 18 SEER HPwith indoor coil CVAMA6124XMA and furnace PG80VTLB66110CCarrier4.5 tons56,000 Btu/h · Ducted2.3453%8.516.011.531,600CEE 25CEE 26132218755094

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 7,036 models; narrow the filters for the rest.