7,036 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1301N5H5S24*K*AAA*HEILwith indoor coil D(A,C,E)37A3J+TDR and furnace *96MSN0802120A | Carrier | 2 tons21,800 Btu/h · Ducted | 2.76 | 72% | 7.5 | 14.8 | 11.7 | 15,500 | CEE 25CEE 26Xcel | 12,665 | 218371357 |
| 1302N5H5S36*K*AAA*HEILwith indoor coil D(A,C,E)36B3J+TDR and furnace *80MS(N,L)1102120A | Carrier | 2.5 tons31,000 Btu/h · Ducted | 2.65 | 69% | 7.5 | 14.8 | 11.7 | 22,800 | CEE 25 | 11,024 | 217597897 |
| 1303N5H5S36*L*AAA*HEIL · PERFORMANCE 16 SEER2 HPwith ducted air handler FHMA5*48L*C | Carrier | 3 tons36,800 Btu/h · Ducted | 2.20 | 48% | 8.0 | 16.0 | 13.0 | 17,400 | CEE 25 | 952 | 217033623 |
| 1304N5H8T24*K*AAA*HEIL · 2-STAGE 18 SEER HPwith indoor coil EA*5X37M21A and furnace *80MSU0401712A | Carrier | 2 tons23,800 Btu/h · Ducted | 2.24 | 45% | 8.5 | 18.0 | 13.0 | 11,100 | CEE 25 | 9,321 | 215647855 |
| 1305N5H8T36*K*AAA*HEIL · 2-STAGE 18 SEER HPwith ducted air handler FTMA5B60L0D | Carrier | 3 tons36,000 Btu/h · Ducted | 2.48 | 49% | 8.5 | 17.0 | 13.0 | 18,600 | CEE 25CEE 26 | 7,347 | 215628950 |
| 1306N5H8T48*K*AAA*COMFORTMAKERwith ducted air handler AE*L+CM48A4J+TDR | Carrier | 4 tons45,000 Btu/h · Ducted | 2.90 | 63% | 7.5 | 17.0 | 12.5 | 29,200 | CEE 25CEE 26 | 5,488 | 218114575 |
| 1307N5H8T60*K*AAA*COMFORTMAKERwith indoor coil C(A,C,D,E)60D2J+TDR and furnace *80CTL0902120B | Carrier | 4 tons48,500 Btu/h · Ducted | 2.70 | 63% | 7.8 | 15.5 | 11.2 | 35,200 | CEE 25CEE 26 | 3,851 | 218687517 |
| 1308N5H9V24*K*AAA*ARCOAIRE · Performance 19 SEER2 VS HPwith ducted air handler FTMA5B36L0C | Carrier | 2 tons23,400 Btu/h · Ducted | 2.02 | 87% | 10.0 | 18.5 | 14.0 | 21,200 | CEE 25CEE 26XcelES CC | 7,747 | 217950375 |
| 1309N5H9V36*K*AAA*ARCOAIRE · Performance 19 SEER2 VS HPwith ducted air handler F5MA5*36L*B | Carrier | 3 tons33,600 Btu/h · Ducted | 2.18 | 77% | 9.0 | 15.2 | 12.0 | 24,800 | CEE 25CEE 26XcelES CC | 5,900 | 217928530 |
| 1310N5H9V48*K*AAA*ARCOAIRE · Performance 19 SEER2 VS HPwith ducted air handler FTMA5B60L0D | Carrier | 4 tons46,000 Btu/h · Ducted | 2.32 | 75% | 10.0 | 19.0 | 12.5 | 36,000 | CEE 25CEE 26XcelES CC | 3,955 | 217914939 |
| 1311N5H9V60*K*AAA*ARCOAIRE · Performance 19 SEER2 VS HPwith ducted air handler F5MA5*60L*D | Carrier | 4.5 tons56,000 Btu/h · Ducted | 2.16 | 70% | 9.0 | 16.0 | 11.7 | 40,000 | CEE 25CEE 26XcelES CC | 2,750 | 217933356 |
| 1312PH5SAN524**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)29J | Carrier | 2 tons21,000 Btu/h · Ducted | 2.64 | 65% | 7.5 | 15.2 | 11.7 | 14,700 | CEE 25CEE 26 | 5,266 | 217006633 |
| 1313PH5SAN524**AB*WEATHERMAKER · 15 SEER2 HPwith ducted air handler FMA5X30**AL | Carrier | 2 tons24,000 Btu/h · Ducted | 2.26 | 49% | 8.5 | 16.5 | 13.0 | 11,600 | CEE 25CEE 26 | 450 | 218754045 |
| 1314PH5SAN531**AA*BRYANT HEATING AND COOLING SYSTEMS · 15 SEER2 HPwith indoor coil CAA**3721AM and furnace 83*CB36040C17 | Carrier | 2.5 tons29,200 Btu/h · Ducted | 2.06 | 46% | 8.0 | 15.5 | 12.0 | 13,900 | CEE 25 | 1,399 | 217680506 |
| 1315PH5SAN531**AB*WEATHERMAKER · 15 SEER2 HPwith indoor coil CAA**3721AM and furnace PG80MS(A,L)A48070C | Carrier | 2.5 tons29,200 Btu/h · Ducted | 2.06 | 46% | 8.0 | 15.0 | 12.5 | 14,100 | CEE 25 | 326 | 218754147 |
| 1316PH5SAN536**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)38J | Carrier | 2.5 tons32,400 Btu/h · Ducted | 2.61 | 60% | 7.5 | 14.3 | 11.7 | 21,000 | CEE 25 | 3,457 | 217006636 |
| 1317PH5SAN536**AB*WEATHERMAKER · 15 SEER2 HPwith ducted air handler FEVB0048**+NAVA54801CK | Carrier | 3 tons36,400 Btu/h · Ducted | 2.22 | 48% | 7.8 | 15.5 | 12.5 | 17,400 | CEE 25 | 351 | 218754040 |
| 1318PH8TAN524**AA*BRYANT HEATING AND COOLING SYSTEMS · 2-STAGE 18 SEER HPwith indoor coil CAA**3721AM and furnace 83*SB36040M17 | Carrier | 2 tons23,800 Btu/h · Ducted | 2.24 | 45% | 8.5 | 18.0 | 13.0 | 11,100 | CEE 25 | 2,154 | 215647849 |
| 1319PH8TAN524**AB*WEATHERMAKER · 2-STAGE 18 SEER HPwith indoor coil CAA**3721AM and furnace PG80MSUA36040B | Carrier | 2 tons23,800 Btu/h · Ducted | 2.24 | 45% | 8.5 | 18.0 | 13.0 | 11,100 | CEE 25 | 362 | 218755458 |
| 1320PH8TAN536**AA*BRYANT HEATING AND COOLING SYSTEMS · 2-STAGE 18 SEER HPwith ducted air handler FT5ANBD60L | Carrier | 3 tons36,000 Btu/h · Ducted | 2.48 | 49% | 8.5 | 17.0 | 13.0 | 18,600 | CEE 25CEE 26 | 1,576 | 215628944 |
| 1321PH8TAN536**AB*WEATHERMAKER · 2-STAGE 18 SEER HPwith ducted air handler PF5TNBD60L | Carrier | 3 tons36,000 Btu/h · Ducted | 2.48 | 49% | 8.5 | 17.0 | 13.0 | 18,600 | CEE 25CEE 26 | 289 | 218755135 |
| 1322PH8TAN548**AA*BRYANT HEATING AND COOLING SYSTEMS · 2-STAGE 18 SEER HPwith ducted air handler FT5ANBD60L | Carrier | 4 tons48,500 Btu/h · Ducted | 2.32 | 51% | 8.1 | 18.0 | 13.5 | 24,600 | CEE 25CEE 26 | 1,195 | 215560713 |
| 1323PH8TAN548**AB*WEATHERMAKER · 2-STAGE 18 SEER HPwith ducted air handler PF5TNBD60L | Carrier | 4 tons48,500 Btu/h · Ducted | 2.32 | 51% | 8.1 | 18.0 | 13.5 | 24,600 | CEE 25CEE 26 | 202 | 218754767 |
| 1324PH8TAN560**AA*BRYANT HEATING AND COOLING SYSTEMS · 2-STAGE 18 SEER HPwith indoor coil CVAMA6124XMA and furnace 88*TB66135C24 | Carrier | 4.5 tons56,000 Btu/h · Ducted | 2.34 | 52% | 8.5 | 15.5 | 11.5 | 31,400 | CEE 25CEE 26 | 756 | 215626620 |
| 1325PH8TAN560**AB*WEATHERMAKER · 2-STAGE 18 SEER HPwith indoor coil CVAMA6124XMA and furnace PG80VTLB66110C | Carrier | 4.5 tons56,000 Btu/h · Ducted | 2.34 | 53% | 8.5 | 16.0 | 11.5 | 31,600 | CEE 25CEE 26 | 132 | 218755094 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 7,036 models; narrow the filters for the rest.