Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

6,849 models

Sorted by manufacturer and model.
Page 7 of 274
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
151H5H3V36*K*AAA*ACIQ · Deluxe 23 VS Heat Pumpwith indoor coil EVD5X60M21A*+WALLCON and furnace *95CSU1002122BACIQ3 tons35,600 Btu/h · Ducted2.1475%9.022.012.528,400CEE 25CEE 26XcelES CC527216635748
152H5H3V48*K*AAA*ACIQ · Deluxe 23 VS Heat Pumpwith indoor coil EA*5X48M21A*+WALLCON and furnace *80CTL0701716BACIQ3.5 tons43,000 Btu/h · Ducted2.0077%9.020.010.537,200CEE 25CEE 26XcelES CC326216635480
153H5H3V60*K*AAA*ACIQ · Deluxe 23 VS Heat Pumpwith indoor coil EA*5X61M21A*+WALLCON and furnace *80CTL0701716BACIQ4.5 tons56,000 Btu/h · Ducted2.1075%8.518.011.045,500CEE 25CEE 26XcelES CC174216635247
154N5H5S24*K*AAA*ACIQ · PERFORMANCE 16 SEER2 HPwith ducted air handler FMA5X30**ALACIQ2 tons24,000 Btu/h · Ducted2.2649%8.516.513.011,600CEE 25CEE 26805216630615
155N5H8T36*K*AAA*ACIQ · 2-STAGE 18 SEER HPwith ducted air handler FTMA5B60L0DACIQ3 tons36,000 Btu/h · Ducted2.4849%8.517.013.018,600CEE 25CEE 26791216631656
156N5H8T48*K*AAA*ACIQ · 2-STAGE 18 SEER HPwith ducted air handler FTMA5B60L0DACIQ4 tons48,500 Btu/h · Ducted2.3251%8.118.013.524,600CEE 25CEE 26575215561906
157N5H8T60*K*AAA*ACIQ · 2-STAGE 18 SEER HPwith indoor coil EVM5X61M24A and furnace *80CTL1352422BACIQ4.5 tons56,000 Btu/h · Ducted2.3452%8.515.511.531,400CEE 25CEE 26419216631510
158N5H9V24*K*AAA*ACIQ · Performance 19 SEER2 VS HPwith ducted air handler FTMA5B36L0CACIQ2 tons23,400 Btu/h · Ducted2.0287%10.018.514.021,200CEE 25CEE 26XcelES CC1,100218019289
159N5H9V36*K*AAA*ACIQ · Performance 19 SEER2 VS HPwith ducted air handler F5MA5*36L*BACIQ3 tons33,600 Btu/h · Ducted2.1877%9.015.212.024,800CEE 25CEE 26XcelES CC836218020881
160N5H9V48*K*AAA*ACIQ · Performance 19 SEER2 VS HPwith ducted air handler FTMA5B60L0DACIQ4 tons46,000 Btu/h · Ducted2.3275%10.019.012.536,000CEE 25CEE 26XcelES CC553218020919
161N5H9V60*K*AAA*ACIQ · Performance 19 SEER2 VS HPwith ducted air handler F5MA5*60L*DACIQ4.5 tons56,000 Btu/h · Ducted2.1670%9.016.011.740,000CEE 25CEE 26XcelES CC387218018905
162R5H5S24*K*AAA*ACIQwith ducted air handler AE*S+CM30B3J+TDRACIQ2 tons21,600 Btu/h · Ducted2.5461%7.515.212.013,700CEE 25CEE 26811217291326
163DBED-T12IH3A1-E*ADB · DBEDwith ductless indoor unit DBED-T12IH3A1-IADB1 ton12,000 Btu/h · Non-ducted1.8083%10.025.013.010,000CEE 25CEE 26XcelES CC1218736480
164DBED-T12IH3A2-E*ADB · DBEDwith ductless indoor unit DBED-T12IH3A2-IADB1 ton12,000 Btu/h · Non-ducted1.8083%10.025.013.010,000CEE 25CEE 26XcelES CC1218736481
165DBED-T18IH3A2-E*ADB · DBEDwith ductless indoor unit DBED-T18IH3A2-IADB1.5 tons18,000 Btu/h · Non-ducted1.8083%10.024.012.015,000CEE 25CEE 26XcelES CC1218736482
166DBED-T24IH3A2-E*ADB · DBEDwith ductless indoor unit DBED-T24IH3A2-IADB2 tons23,000 Btu/h · Non-ducted2.1073%10.023.012.017,500CEE 25CEE 26XcelES CC1218736483
167KUSXA361AADPwith ducted air handler HE34*36+TXV+TDADP3 tons33,600 Btu/h · Ducted1.8092%8.916.011.533,000CEE 25CEE 26Xcel12217198704
168KUSXA422AADPwith ducted air handler HG48*60+TXV+TDADP3.5 tons41,000 Btu/h · Ducted1.9098%8.916.011.741,000CEE 25CEE 26Xcel19217198708
169KUSXA482AADPwith ducted air handler HG48*60+TXV+TDADP4 tons45,500 Btu/h · Ducted1.9090%9.116.011.743,000CEE 25CEE 26Xcel19217198710
170NS18H24HA5***ADPwith ducted air handler HG32*36+TXV+TDADP2 tons24,000 Btu/h · Ducted1.8094%8.816.011.522,600CEE 25CEE 26Xcel2217454849
171A3MO21-18N2-M1AI AIR CONDITIONING · A3M SeriesAI AIR CONDITIONING1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.3077%10.020.012.014,600CEE 25CEE 26XcelES CC3215866801
172A3MO23-18N2-M1HAI AIR CONDITIONING · A3M SeriesAI AIR CONDITIONING1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0090%10.021.013.018,000CEE 25CEE 26XcelES CC3215866815
173A4MO21-27N2-M1AI AIR CONDITIONING · A4M SeriesAI AIR CONDITIONING2 tons26,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.523.012.219,000CEE 25CEE 26XcelES CC3215866803
174A4MO23-27N2-M1HAI AIR CONDITIONING · A4M SeriesAI AIR CONDITIONING2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0096%9.519.012.027,000CEE 25CEE 26XcelES CC3215866819
175A5MO21-36N2-M1AI AIR CONDITIONING · A5M SeriesAI AIR CONDITIONING3 tons35,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%10.023.112.026,000CEE 25CEE 26XcelES CC3215866806

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 6,849 models; narrow the filters for the rest.