Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

7,039 models

Sorted by manufacturer and model.
Page 81 of 282
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
2001DIRM4-18DA25-2ZDIRECT AIR · DIRM SeriesDIRECT AIR1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.3174%9.922.613.014,000CEE 25CEE 26XcelES CC3215213789
2002DIRM4-18DA25-3ZDIRECT AIR · DIRM SeriesDIRECT AIR1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.3174%9.922.613.014,000CEE 25CEE 26XcelES CC3218331784
2003DIRM4-18HXPRO28-1ZDIRECT AIR · DIRM4 Serieswith ducted air handler DIRM4-18HP-DUDIRECT AIR1.5 tons17,500 Btu/h · Ducted and non-ducted2.1092%11.118.412.018,000CEE 25CEE 26XcelES CC4217447834
2004DIRM4-18HXPRO28-2ZDIRECT AIR · DIRM SeriesDIRECT AIR1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0095%10.425.015.019,000CEE 25CEE 26XcelES CC3215213799
2005DIRM4-18HXPRO28-3ZDIRECT AIR · DIRM SeriesDIRECT AIR1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0095%10.425.015.019,000CEE 25CEE 26XcelES CC3218331794
2006DIRM4-18MAGICPRO20-OUDIRECT AIR · DIRM Serieswith ducted air handler DIRM4-2414MAGICP20-CCOILDIRECT AIR1.5 tons18,000 Btu/h · Ducted2.0695%9.516.111.718,000CEE 25CEE 26XcelES CC6216623485
2007DIRM4-24CS19-OUDIRECT AIR · DIRM Serieswith indoor coil DIRM4-2417MAGICP20-CCOIL and furnace DIRM-60GV96UB3-1DIRECT AIR2 tons24,000 Btu/h · Ducted1.9083%9.217.810.820,000CEE 25CEE 26XcelES CC6218160643
2008DIRM4-24DA25-1ZDIRECT AIR · DIR Serieswith ductless indoor unit DIRM4-24HP-WMDIRECT AIR2 tons24,000 Btu/h · Ducted and non-ducted2.5478%11.723.014.019,600CEE 25CEE 26XcelES CC4216571370
2009DIRM4-24HXPRO28-1ZDIRECT AIR · DIR Serieswith ductless indoor unit DIRM4-24HP-WMDIRECT AIR2 tons24,000 Btu/h · Ducted and non-ducted2.3483%13.521.013.024,200CEE 25CEE 26XcelES CC4216571375
2010DIRM4-24MAGICPRO20-OUDIRECT AIR · DIRM Serieswith indoor coil DIRM4-2417MAGICP20-CCOIL and furnace DIRM-60GV96UB3-1DIRECT AIR2 tons24,000 Btu/h · Ducted1.9083%9.217.810.820,000CEE 25CEE 26XcelES CC5218160642
2011DIRM4-27DA25-3ZDIRECT AIR · DIRM SeriesDIRECT AIR2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00100%10.523.012.527,000CEE 25CEE 26XcelES CC3215213790
2012DIRM4-27DA25-3Z*DIRECT AIR · DIRM SeriesDIRECT AIR2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.525.013.019,000CEE 25CEE 26XcelES CC3216683820
2013DIRM4-27DA25-4ZDIRECT AIR · DIRM SeriesDIRECT AIR2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.525.013.019,000CEE 25CEE 26XcelES CC3218331785
2014DIRM4-28HXPRO28-3ZDIRECT AIR · DIRM SeriesDIRECT AIR2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00100%10.523.012.527,000CEE 25CEE 26XcelES CC3215213802
2015DIRM4-28HXPRO28-4ZDIRECT AIR · DIRM SeriesDIRECT AIR2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00100%10.523.012.527,000CEE 25CEE 26XcelES CC3218331797
2016DIRM4-30CS19-OUDIRECT AIRwith ducted air handler DIRM4-30MAGICPRO20-AHDIRECT AIR2.5 tons30,000 Btu/h · Ducted2.0062%8.517.010.719,100CEE 25CEE 2611216571357
2017DIRM4-30DA25-1ZDIRECT AIR · DIR Serieswith ductless indoor unit DIRM4-30HP-WMDIRECT AIR2.5 tons30,000 Btu/h · Non-ducted2.0367%9.520.512.020,000CEE 25CEE 261216571376
2018DIRM4-30MAGICPRO20-OUDIRECT AIR · DIR Serieswith ducted air handler DIRM4-30MAGICPRO20-AHDIRECT AIR2.5 tons30,000 Btu/h · Ducted1.9696%10.016.811.732,600CEE 25CEE 26XcelES CC13216571363
2019DIRM4-36CS19-OUDIRECT AIR · DIR Serieswith ducted air handler DIRM4-36MAGICPRO20-AHDIRECT AIR3 tons36,000 Btu/h · Ducted2.0075%8.716.110.027,000CEE 25CEE 26XcelES CC10216571358
2020DIRM4-36DA25-4ZDIRECT AIR · DIRM SeriesDIRECT AIR3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.524.012.026,000CEE 25CEE 26XcelES CC3215213793
2021DIRM4-36DA25-5ZDIRECT AIR · DIRM SeriesDIRECT AIR3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.524.012.026,000CEE 25CEE 26XcelES CC3218331788
2022DIRM4-36HXPRO28-4ZDIRECT AIR · DIRM SeriesDIRECT AIR3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00100%10.723.013.036,000CEE 25CEE 26XcelES CC3215213805
2023DIRM4-36HXPRO28-5ZDIRECT AIR · DIRM SeriesDIRECT AIR3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00100%10.723.013.036,000CEE 25CEE 26XcelES CC3218331800
2024DIRM4-36LCDA25-1ZDIRECT AIR · DIRM4 Serieswith ductless indoor unit DIRM4-36HP-CADIRECT AIR3 tons36,000 Btu/h · Ducted and non-ducted2.2070%10.320.09.626,600CEE 25CEE 26XcelES CC3216788532
2025DIRM4-36LCHX-1ZDIRECT AIR · DIRM4 Serieswith ducted air handler DIRM4-36HP-DUDIRECT AIR3 tons36,000 Btu/h · Ducted and non-ducted2.1090%11.117.712.037,600CEE 25CEE 26XcelES CC3216788531

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 7,039 models; narrow the filters for the rest.