  1. 1KUMXA421ALG3.5 tons · 42,000 Btu/h · DuctedCold-climate pick, score 89.3Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.27 (COP at 5°F)
    Great
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    13.1 (EER2)
    Top 10%
    91.2score / 100Heating 89 · Cooling 93
  2. 227VNA154A*030*with ducted air handler FE5BNBD60L*+UICarrierAlso sold as Bryant Heating and Cooling Systems 291VAN054**AA4.5 tons · 51,500 Btu/h · DuctedCold-climate pick, score 81.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    102% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    10.5 (HSPF2)
    Top 10%
    Cooling efficiency
    21.0 (SEER2)
    Top 10%
    Hot-day cooling
    13.0 (EER2)
    Top 10%
    90.4score / 100Heating 82 · Cooling 99
  3. 3KUMXA481ALG4 tons · 48,000 Btu/h · DuctedCold-climate pick, score 90.4Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.33 (COP at 5°F)
    Great
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    18.5 (SEER2)
    Great
    Hot-day cooling
    12.6 (EER2)
    Top 10%
    90.1score / 100Heating 90 · Cooling 90
  4. 45TWV0X48A1with indoor coil D(A,C,E)60B4J+TDR and furnace L8V1C100U5VSB+LRPTrane3.5 tons · 42,500 Btu/h · DuctedCold-climate pick, score 93.0Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    107% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.74 (COP at 5°F)
    Top 10%
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    20.4 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Good
    88.9score / 100Heating 93 · Cooling 85
  5. 5ASUM42HPMULOAUX3.5 tons · 42,000 Btu/h · DuctedCold-climate pick, score 76.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    83% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    22.0 (SEER2)
    Top 10%
    Hot-day cooling
    12.3 (EER2)
    Top 10%
    87.0score / 100Heating 77 · Cooling 97
  6. 6SL22KLV-048-230A**with indoor coil CK40[C,U]T-60C-**+TDR and furnace SL280UH080NV60CLennox4 tons · 46,000 Btu/h · DuctedCold-climate pick, score 84.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    98% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.02 (COP at 5°F)
    Good
    Winter efficiency
    9.4 (HSPF2)
    Great
    Cooling efficiency
    20.5 (SEER2)
    Top 10%
    Hot-day cooling
    12.4 (EER2)
    Top 10%
    86.7score / 100Heating 76 · Cooling 97
  7. 7RD18AY48AJVCwith ducted air handler L(E,G)M60IJRheem3.5 tons · 39,000 Btu/h · DuctedCold-climate pick, score 95.2Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    104% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.80 (COP at 5°F)
    Top 10%
    Winter efficiency
    9.0 (HSPF2)
    Good
    Cooling efficiency
    18.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    86.3score / 100Heating 90 · Cooling 83
  8. 8BOVA-60MTB-M19Ewith ducted air handler (V,R)60H210P19*+TXV+AEFE5Bosch4 tons · 48,500 Btu/h · DuctedCold-climate pick, score 90.9Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    103% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    86.3score / 100Heating 85 · Cooling 87
  9. 95A6V0X48A1with indoor coil DH60T4J and furnace S8V2D120M5PCBTrane (sold as American Standard)3.5 tons · 44,500 Btu/h · DuctedCold-climate pick, score 79.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    90% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    20.4 (SEER2)
    Top 10%
    Hot-day cooling
    12.0 (EER2)
    Great
    86.0score / 100Heating 80 · Cooling 92
  10. 10HH860E2S11with ducted air handler D(A,C,E)60B3K+JMC20D2SN1+TDRYork (sold as Coleman)3.5 tons · 43,000 Btu/h · DuctedCold-climate pick, score 90.4Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    81% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.80 (COP at 5°F)
    Top 10%
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    85.7score / 100Heating 84 · Cooling 87

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Want every model’s heating and cooling sub-scores and the all-sizes board? Switch to Advanced

What good looks like: ducted, 3.5–4.5 tons

Good is better than half of this size class, great is the top quarter, top is the top 10%. The scale comes from the class’s own ratings.
  • Capacity at 5°F vs 47°F

    Heating power kept at 5°F

    How much of its mild-weather heating power the unit still delivers at 5°F.

    Good
    71%+
    Great
    84%+
    Top 10%
    98%+
  • COP at 5°F

    Efficiency on a 5°F day

    How much heat the unit makes from each unit of electricity when it is 5°F outside.

    Good
    2.00+
    Great
    2.10+
    Top 10%
    2.36+
  • HSPF2

    Winter-long heating efficiency

    Heating efficiency over a whole winter, measured with a federal test.

    Good
    8.1+
    Great
    9.0+
    Top 10%
    10.4+
  • SEER2

    Summer-long cooling efficiency

    Cooling efficiency over a whole summer, measured with a federal test.

    Good
    15.9+
    Great
    18.0+
    Top 10%
    19.8+
  • EER2

    Hot-day cooling efficiency

    Cooling efficiency on a 95°F afternoon.

    Good
    11.1+
    Great
    11.7+
    Top 10%
    12.0+

Next steps